October 26, 2007
David H. Ready, Esq., Ph.D.
City Manager
City of Palm Springs
3200 E. Tahquitz Canyon Way
Palm Springs, CA 92262
RE: AGREEMENT AS TO AGENCY (FACILITIES PROVIDING WATER FOR
I
ONSITE FIRE SPRINKLER SYSTEMS
I
Dear David:
This letter memorializes the agreement which has been reached between the City of
Palm Springs and Desert Water Agency regarding the Agency's responsibility, and
liability, for Agency facilities installed to supply water to Agency customers and used for
onsite fire suppression purposes, including sprinkler systems. The City and the Agency
have agreed that the Agency will have responsibility and control, and will bear liability,
if any, for water delivery facilities owned, operated and maintained by the Agency for
the delivery of water to Agency customers, including the delivery of water to supply
onsite fire suppression systems including fire sprinkler systems. The Agency's point of
connection for the delivery of such water is located at or near the road or right of way
line, which normally coincides with the property line. Regardless of where located,
however, the Agency will be responsible for such Agency facilities, and will bear all
liability for the type of facilities installed, and for their operation and maintenance by
the Agency. The City will have no responsibility or liability for the installation, operation
or maintenance of those facilities.
The City and the Agency have executed a separate Memorandum of Understanding
regarding the installation of water service laterals, valves and meters to serve single
and non-commercial multi-family residential units, pursuant to which the City has
i
f
DESERT®WATER
David H. Ready, Esq., Ph.D
Page 2
October 26, 2007
agreed to dismiss its lawsuit against the Agency (Los Angeles County Superior Court
Case No. VCO 049377) and the Agency has agreed to dismiss its lawsuit against the
City (Riverside County Superior Court Case No. RIC 4797093).
This letter agreement shall be effective upon execution by both of us, as well as
execution of the Memorandum of Understanding, in settlement of both lawsuits. A
space has been provided for your execution of this letter, below, and an extra copy of
this letter has been provided so that we may have copies executed by both parties.
Thank you for your cooperation in getting this issue resolved.
Sincerely yours,
DESERT WATER AGENCY
David K. Luker
General Manager
Agreed:
David H. Ready, City ManWr
Dated: IOAI
ATra:-sT
7149625018 OCSO Engineering Plann 02:20:55 p.m. 1031-2007 212
kUl'Jl-2UUl WhO U1:b1 Fft Woodruff Spradlin Heart FRX NO. 714 835 7787 P. 02/02
David K PA*,&q.,ph.D
Pap 2
aftber 26,2007
4greed to dismiss Its lawsuit against the Agency (l as Angeles County Superior Court
Case No. VCD 049377) and the Agency has agreed to dismiss Its lawswt against the
City(Rude County Superior Court Case No.RIC 4797093).
This left agreement shall be effective upon euc UUDn by Math of us, as well as
WAaMon of the Memamndrm of Understanding, In settlement of both lawsuits. A
Vwe has been provided for your emcutIm of this letter, below,and an extra copy of
this letter has been provided so that we may have copies executed by bath parties.
'thank you far your cooperation In getting this Issue resolved.
Sincerely yours,
DES3k7VWAT;ORA(G;ENX,
David K. Luk ar
General Manager
Agreed'
David H. Ready,Oty Manager
Dated:
11?G1 ,
rn
MEMORANDUM OF UNDERSTANDING REGARDING THE
INSTALLATION OF WATER SERVICE LATERALS,
VALVES AND METERS TO SERVE SINGLE AND NON-
COMMERCIAL MULTI-FAMILY RESIDENTIAL UNITS FOR
WHICH FIRE SPRINKLERS ARE REQUIRED
This Memorandum of Understanding is executed by and between the City of Palm
Springs and Desert Water Agency regarding the Agency's installation of water service laterals,
valves and meters to serve single and non-commercial multi-family residential units for which the
City requires the installation of on-site fire sprinklers. The purpose of the Memorandum of
Understanding is to set forth in writing a compromise agreement which has been reached between
the City and the Agency regarding the matters hereinafter set forth, pursuant to which the City will
immediately dismiss its lawsuit against the Agency entitled City of Palm Springs et al. vs. Desert
Water Agency Aggney et al., Los Angeles County Superior Court Case No. VCO 049377, and the Agency
will immediately dismiss its lawsuit against the City entitled Desert Water Agency vs. City of Palm
Springy, Riverside County Superior Court Case No. RIC 479093 and each party shall be responsible
for its own attorneys' fees and costs. As to such water delivery facilities installed by the Agency,
the parties agree as follows:
1. Water control valve locks, seals, and meters approved by the Agency will be
acceptable to the City for supplying water to fire sprinkler systems wherever there is a combined
domestic water service with any fire sprinkler systems serving multi-family residential uses (NFPA
13R fire sprinkler systems). The parties will prepare one or more diagrams depicting examples of
suitable configurations and include such diagrams as exhibits to this Memorandum of
Understanding.
2. The City will conduct annual fire sprinkler inspections on all NFPA 13R
systems.
3. The City will provide the Agency with copies of Palm Spring Fire
Department requirements imposed on developments for fire hydrants, fire flow and fire sprinkler
systems, as well as a summary of other fire safety requirements relating to the water supply when
plan review is completed and provided to the owner.
- 1 -
RVPUBIMRIDDRLL1739838.1
......................
..........................
4. Where there is a combined fire/domestic water supply, the City will require
the developer to install individual, accessible domestic water shut-off valves for each unit in
"townhouse" type R-1 occupancies. This will allow the Agency's valves to remain locked open
when repair or maintenance of non-sprinkler related plumbing is required by the occupant.
5. City staff will recommend that the City Council adopt an ordinance making
misappropriation of Agency water a local crime with City enforcement,
6. For any new connection to a combined water service(domestic and fire)to a
multi-family building or project,the Agency will install locks or seals on all control valves from the
meter to the fire sprinkler line branch to ensure that control valves and angle stop valves, when
installed, will be secured in the "open" position. Water control valves (other than the angle stop
valve) shall be indicating type of valves. (Quarter turn valves with handles are acceptable as
"indicating"valves,)
7. Dedicated, stand alone fire service laterals will not be used to supply water to
NFPA 13R fire sprinkler systems,
8. The provisions of Paragraph 6 of this Memorandum of Understanding shall
apply whenever existing fire sprinkler systems water supply control valves to existing multi-family
residential units are replaced.
9. The City's hire Department will have the responsibility for determining the
type of fire sprinkler system required for a building,based on building type and occupancy.
10. The Agency's pressure maps will be provided to the City's Fire Department
and will be basis for fire sprinkler hydraulic calculations. Field verification from existing water
distribution system may also be used to determine fire sprinkler calculations; however, if the field
data differs from the Agency's pressure maps by more than 10%,the lower pressure shall be used to
determine fire sprinkler hydraulics, A licensed C-16 fire protection,contractor, fire protection
engineer, or other professional engineer experienced in fire sprinkler system design and approved
by the City's Fire Department will perform and be fully responsible for all required hydraulic
calculations and determine the gallons per minute and pressure required for automatic fire sprinkler
systems,
11. The Parties acknowledge that the provisions of this MOU are not inconsistent
with.the provisions of all state laws,regulations,orders, and rules, including the 2007 Uniform Fire
-2-
RVPUBVdRNDI)HLL%739838.1
...... . ... ................. .........
i
I
Code, ("state laws") in effect on the date of this MOU. It is the desire of the Parties that this MOU
will be consistent with any amendments to state laws. In the event a law, regulation, order, or rule
adopted or promulgated by a state agency after the effective date of this MOU is inconsistent with
the provisions of this MOU, the Parties agree that they will meet and confer regarding any
necessary or desirable amendment or modification to this MOU in order to ensure continued
consistency with state laws.
City of Palm Springs
City Manager
Date: •�� w3/ a
ATTEST: APPROVED AS TO FORM:
Clerk City Attorney
Desert Water Agency
By:
t /•
Y General Manager
Manager
Date: ✓a
ATTEST: APPROVED AS TO FORM
Secretary Agency Counsel
- 3 -
RVPUB\N4MDELL1739838.1
Code,("state laws')in'effect on the date of this MOU. It is the desire of the Parties that this MOU
will be consistent with any amendments to state laws. In the event a law, regulation,order, or rule
adopted or promulgated by a state agency after the effective date of this MOU is inconsistent with
the provisions of this MOU, the Parties agree that they will meet and confer regarding any
necessary or desirable amendment or modification to this MOU in order to ensure continued
consistency with state laws.
City of Palm Springs
By. �
City Manager
Date:
ATTEST: APPROVED3=� MI.k
:%M1�r'S• Yy4'} "KCW •' .g F
C,'4Y
City Clerk "Att�s>�hb3�
Desert Water Agency
By:
General Manager
Date: 10L-,V 0 A0W7
ATTEST: APPROVED AS TO FORM
Secretary Agency Counsel
.3 -
RYPUBURDDEW739838.1
I
9
v o
8 v
9
6 4 _.3 1
4 3
WATERMA1N
2
1
APPROVED
ITEM No? DESCRIPTION MATERIALS
REQ D. LIST NO.
I i SERVICE CONNECTION PER STANDARD DRAWING W124 OR STANDARD DRAWING W125. SEE DWG. W124
OR W125
2 VARIES TYPE "K" SOFT COPPER TUBING. A--05
3 1 ANGLE METER STOP WITH DWA SEAL. B-05
4 1 METER (SIZE AND TYPE AS SPECIFIED). N/A
5 1 METER BOX WITH LID MARKED "DWA". E-01
6 1 STANDARD WEIGHT BRASS PIPE A-06
7 1 BACKFLOW DEVICE WITH LOCKS B-08
8 1 BRASS CROSS E-06
9 1 CAPPED OUTLET FOR FUTURE FIRE SERVICE PIPING AND FUTURE SERVICE D-05
1D 1 CUSTOMER CONTROL VALVE AND PRECAST CONCRETE VALVE BOX H-12
NOTES
1) COPPER SERVICE TUBING SHALL BE LAID STRAIGHT AND AT RIGHT ANGLES TO THE WATERMAIN.
2) METER 13OX SHALL BE AT LEAST 5' FROM EDGE OF DRIVEWAY (CURB DROP) OR FROM DRIVEWAY RADIUS.
3) PIPE THREADS SHALL BE CLEAN AND SHARP AND SEALED WITH AN APPROVED JOINT COMPOUND.
4) INSTALLATION OF APPURTENANCES FROM ANGLE METER STOP THROUGH CUSTOMER SERVICE VALVE WILL BE BY AGENCY.
5) CUSTOMER CONTROL VALVE SHALL BE BEHIND BACKFLOW DEVICE IF BACKFLOW DEVICE IS REQUIRED.
P
RO DATE�� DESERT WATER AGENCY
PALM SPRINGS, CALIFORNIA
EER
SCE NO. 5851�4 MULTI--FAMILY SERVICE
INSTALLATION WITH
FIRE SERVICE
REVISION BY DATE STANDARD DRAWING W128
.. ....
AKI
Q a
o s
0 9 S 7 4
AMMON&WETI M AS REOMEA
4 5 3 WATER.UM
4
WATERUAIN
WRIL COIApAATEO EARTH
• 2
APPROVED
ITEM READ. DESCRIPTION MATERIALS
LIST NO.
1 1 SERVICE CONNECTION PER STANDARD DRAWING W124 OR STANDARD DRAWING W125. SEE DWG, W124
OR W125
2 VARIES TYPE "K" SOFT COPPER TUBING. A-05
3 1 ANGLE METER STOP WITH DWA SEAL. 8-05
4 1 METER (SIZE AND TYPE AS SPECIFIED). N/A
5 1 METER BOX WITH LID MARKED "DWA". E-01
6 1 STANDARD WEIGHT BRASS PIPE A-06
7 1 BACKFLOW DEVICE WITH LOCKS B-08
8 1 BRASS CROSS D—Q5
9 1 CAPPED OUTLET FOR FUTURE FIRE SERVICE PIPING AND FUTURE SERVICE E-06
10 1 CUSTOMER CONTROL VALVE AND PRECAST CONCRETE VALVE BOX H-12
NOTES
1) COPPER SERVICE TUBING SHALL BE LAID STRAIGHT AND AT RIGHT ANGLES TO THE WATERMAIN.
2) METER BOX SHALL BE AT LEAST 5' FROM EDGE OF DRIVEWAY (CURB DROP) OR FROM DRIVEWAY RADIUS.
3) PIPE THREADS SHALL BE CLEAN AND SHARP AND SEALED WITH AN APPROVED JOINT COMPOUND.
4) INSTALLATION OF APPURTENANCES FROM ANGLE METER STOP THROUGH CUSTOMER SERVICE VALVE WILL BE BY AGENCY.
5) CUSTOMER CONTROL VALVE SHALL BE BEHIND BACKFLOW U VICE IF BACKFLOW DEVICE IS REQUIRED.
dPPR
WEER
Ov DATE DESERT WATER AGENCY
PALM SPRINGS, CALIFORNIA
RCE NO. 58514 MULTI--FAMILY SERVICE
OAERAIT
INSTALLATION WITH
MANIFOLD FIRE SERVICE
REVISION BY DATE STANDARD DRAWING W129