Loading...
HomeMy WebLinkAbout9/6/2017 - AGREEMENTS (2)OPEN OPEN OPEN OPEN OPEN 020 020 008 011 903 806 806806 806 806 810 810 016 803 803 803 862 881 881 803 862 881 017 TYP. 917 1. REMOVE EXISTING WALKWAY PADS IN AREAS TO RECIEVE NEW ROOFING. PROVIDE NEW ROOF WALKWAY PADS PER SPECIFICATION AND DETAIL AS REQUIRED. 2. EXISTING MEMBRANE ROOF SYSTEMS TO REMAIN TO BE INSPECTED FOR INSTALLATION AND INTEGRITY, REPAIRED IF NECESSARY, AND WARRANTY PROVIDED TO MATCH NEW INSTALLATIONS PER SPECIFICATION. 3. SEAL ANY PENETRATIONS TO ROOF MEMBRANE. E CK EFR AI REN. 09/10/17 FE AT S T LFCAO ILFEJC018223 . O AINR A T ZTSNEC Y DE CAR T HI Project: Description: Date: Project Number: Sheet: Drawn By: Checked By: Sheet Title: Approved By: Sheet Number:www.jeffkatzarchitecture.comOF 5 CITY REVIEW 11/16/16 BID SET 05/31/176353 DEL CERRO BOULEVARD SAN DIEGO, CA 92120 619.698.9177CITY HALL 160901 A2.1 PALM SPRINGS RE-ROOFING CITY OF PALM SPRINGS TYPICAL ROOFING DETAILS MK JK MNK CONSTRUCTION NOTES 008 EXISTING METAL ROOF TO REMAIN, PROTECT IN PLACE 011 EXISTING TAR AND GRAVEL ROOF TO BE REPLACED WITH MEMBRANE ROOF OVER NEW SUBSTRATE PER SEPCIFICATION. 016 EXISTING MECHANICAL UNIT TO REMAIN, PROTECT IN PLACE. 017 EXISTING ROOF ACCESS HATCH, PROTECT IN PLACE 020 EXISTING MEMBRANE ROOF TO REMAIN, PROTECT IN PLACE 803 REMOVE EXISTING METAL PARAPET CAP AND PROVIDE NEW PARAPET CAP DETAIL PER SPECIFICATIONS. (APPROX 1000 LF) 806 NEW MEMBRANE ROOF OVER EXISTING ROOF SYSTEM PER SPECIFICATION, PROTECT IN PLACE ALL ROOF MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED. 810 NEW MEMBRANE ROOF OVER EXISTING ROOFING SYSTEM AND WALL FLASHING DETAIL PER SPECIFICATION AT EXISTING MECHANICAL WELL, PROTECT IN PLACE ALL ROOF MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED. 862 EXPANSION JOINT DETAIL PER SPECIFICATION, (APPROX. 65 LF) 881 EDGE FLASHING DETAIL PER SPECIFICATION 903 DISCONNECT AND REMOVE EXISTING MECHANICAL UNITS AND EQUIPMENT CURBS. PROVIDE NEW PREMANUFACTURED EQUIPMENT CURB DETAIL PER SPECIFICATION, MINIMUM 8" HIGH. REINSTALL, RECONNECT, AND START UP EXISTING MECHANICAL UNITS, 917 REPLACE EXISTING CONDUIT SLEEPERS WITH NEW ROOFTOP SUPPORTS PER SPECIFICATION. REPAIR EXISTING CONDUIT AS NECESSARY. SCALE: 1/32" = 1'-0"A2.1 D1 CITY HALL GENERAL NOTES 806 884 801 802 834 TYP. 882 801 TYP. 917 1. REMOVE EXISTING WALKWAY PADS IN AREAS TO RECIEVE NEW ROOFING. PROVIDE NEW ROOF WALKWAY PADS PER SPECIFICATION AND DETAIL AS REQUIRED. 2. EXISTING MEMBRANE ROOF SYSTEMS TO REMAIN TO BE INSPECTED FOR INSTALLATION AND INTEGRITY, REPAIRED IF NECESSARY, AND WARRANTY PROVIDED TO MATCH NEW INSTALLATIONS PER SPECIFICATION. 3. SEAL ANY PENETRATIONS TO ROOF MEMBRANE. E CK EFR AI REN. 09/10/17 FE AT S T LFCAO ILFEJC018223 . O AINR A T ZTSNEC Y DE CAR T HI Project: Description: Date: Project Number: Sheet: Drawn By: Checked By: Sheet Title: Approved By: Sheet Number:www.jeffkatzarchitecture.comOF 5 CITY REVIEW 11/16/16 BID SET 05/31/176353 DEL CERRO BOULEVARD SAN DIEGO, CA 92120 619.698.9177SWIM CENTER 160901 A2.2 PALM SPRINGS RE-ROOFING CITY OF PALM SPRINGS TYPICAL ROOFING DETAILS MK JK MK CONSTRUCTION NOTES 801 REMOVE EXISTING ROOFING SYSTEM AND SUBSTRATE AND REPLACE WITH NEW MEMBRANE ROOF OVER NEW SUBSTRATE PER SPECIFICATION 802 PROVIDE NEW GRATE FOR EXISTING ROOF DRAIN. 806 NEW MEMBRANE ROOF OVER EXISTING ROOF SYSTEM PER SPECIFICATION, PROTECT IN PLACE ALL ROOF MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED. 834 ROOF DRAIN DETAIL PER SPECIFICATION 882 PROVIDE BEAM CAP DETAIL PER SPECIFICATION (APPROX 150LF) 884 REMOVE EXISTING METAL PARAPET CAP AND PROVIDE NEW PARAPET CAP DETAIL PER SPECIFICATIONS. (APPROX 100 LF) 917 REPLACE EXISTING CONDUIT SLEEPERS WITH NEW ROOFTOP SUPPORTS PER SPECIFICATION. REPAIR EXISTING CONDUIT AS NECESSARY. SCALE: 1/16" = 1'-0"A2.2 D1 SWIM CENTER GENERAL NOTES OPEN 808 011 TYP. 807 TYP. 803 TYP. 803 TYP. 803 TYP. 803 TYP. 803 020 020 020020 020 020 020 020 833833 808 TYP. 917 1. REMOVE EXISTING WALKWAY PADS IN AREAS TO RECIEVE NEW ROOFING. PROVIDE NEW ROOF WALKWAY PADS PER SPECIFICATION AND DETAIL AS REQUIRED. 2. EXISTING MEMBRANE ROOF SYSTEMS TO REMAIN TO BE INSPECTED FOR INSTALLATION AND INTEGRITY, REPAIRED IF NECESSARY, AND WARRANTY PROVIDED TO MATCH NEW INSTALLATIONS PER SPECIFICATION. 3. SEAL ANY PENETRATIONS TO ROOF MEMBRANE. E CK EFR AI REN. 09/10/17 FE AT S T LFCAO ILFEJC018223 . O AINR A T ZTSNEC Y DE CAR T HI Project: Description: Date: Project Number: Sheet: Drawn By: Checked By: Sheet Title: Approved By: Sheet Number:www.jeffkatzarchitecture.comOF 5 CITY REVIEW 11/16/16 BID SET 05/31/176353 DEL CERRO BOULEVARD SAN DIEGO, CA 92120 619.698.9177LEISURE CENTER 160901 A2.3 PALM SPRINGS RE-ROOFING CITY OF PALM SPRINGS TYPICAL ROOFING DETAILS MK JK MNK CONSTRUCTION NOTES 011 EXISTING TAR AND GRAVEL ROOF TO BE REPLACED WITH MEMBRANE ROOF OVER NEW SUBSTRATE PER SEPCIFICATION. 020 EXISTING MEMBRANE ROOF TO REMAIN, PROTECT IN PLACE 803 REMOVE EXISTING METAL PARAPET CAP AND PROVIDE NEW PARAPET CAP DETAIL PER SPECIFICATIONS. (APPROX 1000 LF) 807 PATCH ROOFING MEMBRANE WHERE DAMAGED FROM PALM TREE FRAWNS. APPROXIMATELY 10 SF (1' X 1' EACH PATCH) 808 PROVIDE MECHANICAL ATTACHMENT (ROOFING MANUFACTURER APPROVED) AT 12" O.C. TO MINIMIZE "PILLOWING" OF ROOF MEMBRANE. (APPROX 80 SF) 833 EDGE FLASHING DETAIL PER SPECIFICATION 917 REPLACE EXISTING CONDUIT SLEEPERS WITH NEW ROOFTOP SUPPORTS PER SPECIFICATION. REPAIR EXISTING CONDUIT AS NECESSARY. SCALE: 1/32" = 1'-0"A2.3 D1 LEISURE CENTER GENERAL NOTES 809 020020 020 020020 020 020 020 020 020 846 011 TYP. 917 1. REMOVE EXISTING WALKWAY PADS IN AREAS TO RECIEVE NEW ROOFING. PROVIDE NEW ROOF WALKWAY PADS PER SPECIFICATION AND DETAIL AS REQUIRED. 2. EXISTING MEMBRANE ROOF SYSTEMS TO REMAIN TO BE INSPECTED FOR INSTALLATION AND INTEGRITY, REPAIRED IF NECESSARY, AND WARRANTY PROVIDED TO MATCH NEW INSTALLATIONS PER SPECIFICATION. 3. SEAL ANY PENETRATIONS TO ROOF MEMBRANE. E CK EFR AI REN. 09/10/17 FE AT S T LFCAO ILFEJC018223 . O AINR A T ZTSNEC Y DE CAR T HI Project: Description: Date: Project Number: Sheet: Drawn By: Checked By: Sheet Title: Approved By: Sheet Number:www.jeffkatzarchitecture.comOF 5 CITY REVIEW 11/16/16 BID SET 05/31/176353 DEL CERRO BOULEVARD SAN DIEGO, CA 92120 619.698.9177PAVILION 160901 A2.4 PALM SPRINGS RE-ROOFING CITY OF PALM SPRINGS TYPICAL ROOFING DETAILS MK JK MNK SCALE: 1/32" = 1'-0"A2.4 D1 PAVILION CONSTRUCTION NOTES 011 EXISTING TAR AND GRAVEL ROOF TO BE REPLACED WITH MEMBRANE ROOF OVER NEW SUBSTRATE PER SEPCIFICATION. 020 EXISTING MEMBRANE ROOF TO REMAIN, PROTECT IN PLACE 809 HATCH TO BE REMOVED AND REINSTALLED (X2). PROVIDE EQUIPMENT CURB, DETAIL PER SPECIFICATION. 846 REPAIR / REPLACE EXISTING MEMBRANE ROOFING AS REQUIRED TO PROVIDE PROPER ROOF DRAIN, DETAIL PER SPECIFICATION. 917 REPLACE EXISTING CONDUIT SLEEPERS WITH NEW ROOFTOP SUPPORTS PER SPECIFICATION. REPAIR EXISTING CONDUIT AS NECESSARY. GENERAL NOTES 2:122:12883 810 902 805 804 017 017 017 803 803 803 806 806 869816 864 864864 864 847 864 TYP. 834 880 TYP. 917 1. REMOVE EXISTING WALKWAY PADS IN AREAS TO RECIEVE NEW ROOFING. PROVIDE NEW ROOF WALKWAY PADS PER SPECIFICATION AND DETAIL AS REQUIRED. 2. EXISTING MEMBRANE ROOF SYSTEMS TO REMAIN TO BE INSPECTED FOR INSTALLATION AND INTEGRITY, REPAIRED IF NECESSARY, AND WARRANTY PROVIDED TO MATCH NEW INSTALLATIONS PER SPECIFICATION. 3. SEAL ANY PENETRATIONS TO ROOF MEMBRANE. E CK EFR AI REN. 09/10/17 FE AT S T LFCAO ILFEJC018223 . O AINR A T ZTSNEC Y DE CAR T HI Project: Description: Date: Project Number: Sheet: Drawn By: Checked By: Sheet Title: Approved By: Sheet Number:www.jeffkatzarchitecture.comOF 5 CITY REVIEW 11/16/16 BID SET 05/31/176353 DEL CERRO BOULEVARD SAN DIEGO, CA 92120 619.698.9177DEMUTH COMMUNITY CENTER 160901 A2.5 PALM SPRINGS RE-ROOFING CITY OF PALM SPRINGS TYPICAL ROOFING DETAILS MK JK MNK SCALE: 1/32" = 1'-0"A2.5 D1 DEMUTH COMMUNITY CENTER CONSTRUCTION NOTES 017 EXISTING ROOF ACCESS HATCH, PROTECT IN PLACE 803 REMOVE EXISTING METAL PARAPET CAP AND PROVIDE NEW PARAPET CAP DETAIL PER SPECIFICATIONS. (APPROX 1000 LF) 804 REMOVE AND REPLACE EXISTING METAL STANDING SEAMROOF WITH NEW SIMULATED MEMBRANE STANDING SEAM ROOF OVER EXISTING SUBSTRATE PER SPECIFICATION. 805 PROVIDE NEW MEMBRANE ROOF OVER MECHANICALLY ATTACHED COVER BOARD PER SPECIFICATION, OVER EXISTING FOAM ROOF SYSTEM TO REMAIN. EXISTING MECHANICAL UNITS TO REMAIN, REFERENCE SPECIFICATION. PROVIDE NON-LIFTABLE UNIT DETAIL AT EXISTING EQUIPMENT CURBS, TYPICAL OF 7. 806 NEW MEMBRANE ROOF OVER EXISTING ROOF SYSTEM PER SPECIFICATION, PROTECT IN PLACE ALL ROOF MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED. 810 NEW MEMBRANE ROOF OVER EXISTING ROOFING SYSTEM AND WALL FLASHING DETAIL PER SPECIFICATION AT EXISTING MECHANICAL WELL, PROTECT IN PLACE ALL ROOF MOUNTED EQUIPMENT UNLESS OTHERWISE NOTED. 816 EXISTING METAL STANDING SEAM AT SOFFIT TO REMAIN, PROTECT IN PLACE. 834 ROOF DRAIN DETAIL PER SPECIFICATION 847 ROOF RIDGE DETAIL PER SPECIFICATION 864 WALL FLASHING DETAIL PER SPECIFICATION 869 WALL FLASHING DETAIL PER SPECIFICATION (SIMILAR) AT BOTTOM EDGE 880 GUTTER FLASHING DETAIL PER SPECIFICATION(SIMILAR) AT TOP EDGE 883 REMOVE AND REPLACE EXISTING METAL STANDING SEAM ROOF WITH NEW MEMBRANE ROOF OVER EXISTING SUBSTRATE PER SPECIFICATION 902 DISCONNECT AND REMOVE EXISTING MECHANICAL UNITS AND EQUIPMENT CURBS. PROVIDE NEW PREMANUFACTURED EQUIPMENT CURB DETAIL PER SPECIFICATION. REINSTALL, RECONNECT, AND START UP EXISTING MECHANICAL UNITS, TYPICAL OF 4. 917 REPLACE EXISTING CONDUIT SLEEPERS WITH NEW ROOFTOP SUPPORTS PER SPECIFICATION. REPAIR EXISTING CONDUIT AS NECESSARY. GENERAL NOTES