Loading...
HomeMy WebLinkAbout2016-1873 - 248 Orchid Tree LnDate 05/19/2016 Submitted Owner Rod Ramsour Contractor Brudvik Inc Architect Engineer Lot # Block # 70 + Lot Size 10400 Building Sq. Ft. New Use of building SFD Fire Sprinkler Units City of Palm Springs 40 BUILDING PERMIT Building Address: 248 Orchid Tree Ln Case No.: Address 248 Orchid Tree Ln Palm Springs CA Address 600 Eugene Rd Palm Spirngs CA Address Address Tract ENCHANTHOMES Zone2 Permit Angela LaFrance Technician Phone Phone Lic. Number 760 3204429 482623 Phone Phone Parcel Number 602-091-013 Occupancy Garage/Carport Roofed Patio/Porch Permit Type Electric Service Upgrade Valuation Permit Fees Paid 2500.00 121.00 Remodeled Area Describe work in detail: Upgrade main service panel to 400 amp. Includes undergrounding service. Special Conditions: Const. Type Fixture Units DO NOT CONCEAL OR COVER ANY CONSTRUCTION UNTIL THE WORK IS INSPECTED 111A0 IL?TAKIT The issuance of this permit shall not be held to be an approval of the violation of any provisions of any city or county ordinance or state law. Inspections of work are subject to an approved set of plans being on the job. Changes to plans are not to be made without permission of the Building and Safety Divisions. The owner and/or contractor is responsible for establishing all property lines. All utilities must be underground. This permit will expire if work is not started in 180 days or if more than 180 days elapses between inspections. I certify that I am familiar with all requirements of the City of Palm Springs as they apply to this permit and understand that these requirements must be compl d prior to final inspectio that no certification of occupancy will be issued until such time as these requirements met. I certify that I have read)Vs application arytate a e information is true and correct. O FINAL CALLED 'E MIT EXPIRED OWN ER/CONTR TOR/ ENT DATE D m�.T mar, n This is a building permit when YAperly filled out, signed and validated, and is not transferable. PERMITNUMBER 2016-1873 • 0 INSPECTION INFORMATION No work shall be concealed without a signature by the inspector. The approved plans and this card must always be available to the inspector. Preserve this record. A permit shall expire and become null and void if substanial work is not commenced within 180 days, or if the work is suspended or abandoned for a period of 180 days. If the work is progressing but approaching the end of the 180 day period from the last recorded day of a passed inspection, a progress inspection must be obtained to keep an active permit. CONSTRUCTION HOURS Weekdays 7am to 7pm Saturdays 8am to 5pm Sundays & Holidays Not Permitted JOB NOTES: JOB CARD Project address: 248 Orchid Tree Ln Permit #: 2016-1873 Inspection hours 8AM - 4PM Monday - Thursday Inspection request line (760) 323-8243 Building Department (760) 323-8242 Building Department Fax (760) 322-8342 ELECTRIC SERVICE UPGRADE INSPECTIONS Meter Release -1 % 141Id Gcr• Final NO FMt J., PERMIT EXPIRE D FILE CLOSED `"' Paid Rellit Summary City of Palm Springs p rj/ 9 3200 East Tahquitz Canyon Way Page 1 of 1 Palm Springs, CA 92262 4rxaIt DATE 5/19/2016 Phone: Bldg: 760-323-8242 Eng: 760-323-8253 Fax: See Below ACCOUNT: Brudvik Inc 600 Eugene Rd Palm Spirngs CA 92264 Phone: 760 320 4429 PERMIT NUMBER 1 2016-1873 248 Orchid Tree Ln Palm Springs, CA Date Reference Number Invoice Number FeeCat Description Status Amount 5/19/2016 2016-1873 16-2155 001-32201 RESIDENTIALMEPFEES Paid (-) 78.00 5/19/2016 2016-1873 16-2155 001-32204 PERMITPROCESSINGFEE Paid (-) 33.00 5/19/2016 2016-1873 16-2155 001-32219 S.B.1473 Paid (-) 1.00 5/19/2016 2016-1873 16-2155 001-34308 Microfilm Paid (-) 4.00 5/19/2016 2016-1873 16-2155 001-37111 SMIP1 Paid (-) 1.00 5/19/2016 2016-1873 16-2155 261-32214 Technology Fee Paid (-) 4.00 Date InvoiceNum Status Payment Amount 5/19/2016 16-2155 OriginalDue 121.00 5/19/2016 16-2155 Paid Check093319 (-) 121.00 [Total Paid 121.00 Building Fax #: 760-322-8342 Engineering Fax #: 760-322-8325 • • Services ELECTRICAL LOAD CALCULATIONS RESIDENCIAL PROJECT:248 NORTH ORCHID TREE LANE Palm Springs COMPUTED LOAD (ARTICLE 220) 3100 GENERAL LIGHTING LOAD @ 3 WATTS PER SQUARE FOOT 9300 2 SMALL APPLAINCE LOAD @ 1500 WATTS EACH 3000 2 LAUNDRY LOAD @ 1500 WATTS EACH 3000 TOTAL GENERAL LIGHTING AND SMALL APPLIANCE LOAD 15300 DEMAND FACTOR (ARTICLE 220.42) FIRST 3000 WATTS OR LESS @ 100% 3000 FROM 3001 TO 120,000 WATTS @ 35% 4305 NET GENERAL LIGHTING AND SMALL APPLIANCE LOAD 6780 FIXED APPLIANCE LOADS (ARTICLE 220.53) WATTS PER 1 NON DERATED FUTURE 8000 8000 2 MICROWAVE 1500 3000 3 FAU 600 1800 1 DISHWASHER 1200 1200 1 GARBAGE DISPOSAL 600 600 DEMAND FACTOR 75% TOTAL WITH DEMAND FACTOR 10950 OTHER LOADS WATTS PER 4 AIR CONDITIONER 21000 21000 1 RANGE 5600 5600 1 POOL EQUIPMENT 4000 4000 TOTAL OTHER LOADS 30600 TOTAL LOAD 52635 52635 WATTS/240 VOLTS= 220AMPS REQUIRED IMP AMP SERVICE 1 0 Service Section Upgrade -Change out Conduit & Conductor Size Service Secti-on Size _ _. ub P a t: l Size Conductor Size onduit Size I Grounding Electrode Conductor Size (250.66) — Size Water Bond or Augment to Electrode Size C) (250.66) Size Banding Conductor for Gas Piping System ✓ (250.122) A minimum of two S' driven ground rods spaced at least 6' apart shall be installed in the absence of a concrete encased electrode (uffer). Table 250.122 Minimum Size Equipment Grounding Conductors for Grounding Raceway and Equipment Table 250.66 Grounding Electrode Conductor for Size (ANVG or kcmil) Aiternafinn Current Systems Rating or Setting of Size, of Largest Ungrounded Automatic Overcurrent Service-Entraure Device in Circuit Ahead Aluminum Conductor or Equivalent Size of Grounding of Equipment, Conduit, or Copper - Area for Parallel Electrode Conductor a (_4WGlkemil) etc., Not Exceeding Clad Coaductorm (.ILNVG/kcmil) (Amperes) Copper Aluminum* Aluminum Aluminum 15 14 12 or Copper- or Clad Copper- 20 30 12 10 10 8 —C lMir Aluminum PPa —ter Clad Aluminum 40 10 8 e 2 or smaller 1/0 or smaller 9 6 60 10 8 1 or 110 7 10 or 3s'0 6 4 100 8 6 200 6 4 20 or 310 4/0 or 250 4 2 Over 3/0 Over 250 2 110 300 4 2 through 310 through. 500 400 3 1 Over $50 Over 500 U0 310 500 2 110 through 600 through 900 600 1 2, 0 Over 600 Over 900 2/ 0 4,0 ;hroaA 1100 through 1750 800 1/0 3,!0 1000 2/0 4'0 Over 1100 Over 1750 3."0 250 Notes: 1200 3/0 250 � L. Where multiple sets of service -entrance conductors are used 1600 4/0 350 2000 250 400 as permitted in 230.40, Exception No. 2, the equivalent sue of the largest service -entrance conductor shall be determined by 2300 350 600 the largest sum of the areas of the corresponding conductors of 3000 400 600 each set 4000 500 � 3. 2. Where there are no service -entrance conductors, the grounding electrode conductor size shall be determined by the 5000 700 1200 equivalent sue of the largest service -entrance conductor 6000 800 1200 required for the load to be served. Note; Where necessary to comply with 250.4(A)(5) or (E)(4), 'This table also applies to the derived conductors of separately the equipment grounding conductor shall be sized larger than derived ae systems. given in this table. r w k Table 310 15(B)(I Conductor Types and Sizes for 120/240- Volt, 3-Wire, Single-phase Dwelling Services and Feeders. Conductor Types REH, RAW, 'RHW-2, TE0 N, TBMW, TlaW, TEW-2, THWN, TMY t-2, XEHW, )04AW-2, SE, USE, USE-2 Conductor (-4WG or kcm11) Service or Feeder Copper Aluminum or Rating (_amperes) Copper -Clad Aluminum 100• 4 2 Ito 3 1 125 2 10 150 1 10 175 10 3 0 200 2 0 40 225 30 250 230 40 300 300 250 350 350 330 500 400 400 600 Table 310. (formerly Table 310.16) Allowable Ampacides of Insulated Conductors Ratedj= 2000 Volts, 60°C Through 90°C (140°F Through 194°2), Not More Than Three Current -Carrying Conductors in Raceway, Cable, or Earth (Directly Buried), Based on Ambient Temperature of 300C (Be a Temperature Rating of Conductor (See Table 310.13.) 60eC (140-F) 75°C 90°C (1940$) 60-C 75°C 900C (194°F) (167-F) (140"F) (167°F) Ty0d �s' SA, -- - Types SLR, FEP, FEPB, bf7, REA RHW-2, . Types Types TBS, SA, RHW, TERN, THHW, RHW, SIS, TEM, ' T , TRW-2, TH"-2, THEW, THEW, THW-2, THWI USE-2, XHH, T$W. THWN-2,.RHS, Types TW, OF TH"' XHHW, XEIffqr, XHE[yy-2, Z,-2 Types TW, THWN, XHHW, RHW-2, USE-2, XHH, XHHW Size AWG or USE, Zw OF USE XHHW-2, ZW Z Size AWG or COPPER ALUhm` mi OR COPPER -CLAD ALUI4IINUhI kemil kens0 is - _ 14 16 — — 18- 142 ® 20 25 — — 12M . 25 30 ® 20 25 12M 10® 30 35 40 25 30 35 10n 8 40 50 55 40 45 8 6 55 65 75 40 50 6 4 70 85 95 55 65 75 4 3 85 100 65 75 85 3 2 95 I15 130 75 90 100 2 1 110 130 ® 85 100 115 1 1/0 125 150 110 too 120 135 U0 ` 2/0 L45 175 195 115 135 150 2/0 310 165 200 225 130 155 175 3/0 4/0 195 230 260 L50 180 205 410 250 215 255 290 170 205 230 250 300 240 285 320 0 230 M 300 350 260 310 350 210 250 280 350 400 280 335 380 225 270 305 400 Soo 320 380 430 260 310 350 500 600 ® 420 475 285 340 385 600 700 385 460 520 I 375 N 700 710 400 475 535 320 385 435 750 Soo 4.10 490 555 330 395 Soo 900 435 520 585 355 425 490 900 1000 455 545 615 375 445 Soo L000 1250 495 590 665 405 485 545 1250 1500 EM 625 705 435 520 585 1500 1750 545 650 735 455 545 615 1750 2000 665 750 470 560 630 2000 OF PALM S PR u x C'q�IFOR��P; BUILDING PERMIT APPLICATION DATE: 05/10/2016 Project Address 248 North Orchid Tree Lane Owner's Name Rod Ramsour Owner's Address Contractor's Name Brudvik, Inc. Contractor's Address 600 S. Eugene Rd, Palm PLAN CHECK DEPOSIT FEE: Assessor's Parcel # Phone # Phone # 760-320-4429 LIC# 482623 92264 Architect's Name N/A Phone # N/A Architect's Address N/A Engineer's Name N/A Engineer's Address N/A Phone # N/A Lic.# N/A Lic.# N/A CONTACT PERSON Lenard Rymer Address 600 S. Eugene Rd, Palm Springs, CA, 92264 PHONE 760-272-4728 FAX 760-323-3302 MAIL service@brudvikinc.com Business License. # 615 , Expiration D e 02/28/1-t Lot Size (sf.) Building Use Type of Const. O Group(s) Sprinkled Project Square Footage: Building Garage Carport Patio (type) Project Description New Electrical Panel 4�_ c-D otal Value of Work $ 2,500 WHERE INDICATED BY A CHECK, SUBMIT 3 SETS (Minimum size of plans *18 x 24" Minimum scale %"=1';Maximum size of plans 40" x 36") ❑ Complete Application. ❑ Plot Plan with lot square footage. ❑ Drainage Plan: show lot corner elevations. ❑ Structural Calculations, if applicable (wet -stamped and signed) ❑ Floor Plan, dimensioned. Door & Window Schedule ❑ Framing Plan with sections and elevations ❑ Truss Calculations and layout as applicable (wet -stamped and signed.) ❑ Foundation Plan ❑ Electrical Plan/Load Calculations include 8-KW future for new single dwellings and condos Bldg. Plan Check #, Planning Case #_ ❑ Waste, Drain & Vent Isometric ❑ Gas/Water Piping Isometric (dimensioned layout) ❑ Details showing compliance with accessibility. requirements ❑ Site Plan showing parking for persons with disabilities and path of travel to building entrance ❑ Title 24 (Energy) — 2 sets/ Lighting Compliance Forms ❑ Manufacture's brochure for HVAC equipment ❑ Mech. Plan / Duct Schematic, equipment location ❑ Fireplace Specifications, if applicable ❑ Planning / Fire / Engineering approval ❑ Health Department approval Signature 0 0 OWNER / BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's License Law for the following reason (Section 70 31.5, Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any Structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 commencing with Sec. 7000 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).) Please check one of the following: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044 of the Business and Profession Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044 of the Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. of the Business and Professions Code for this reason: Owner Signature: Date: LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. The following applies to B contractors only: I understand the limitations of Section 7057 related to my ability to take prime contracts or subcontracts involving specialty trades. License Class: C10 C20 C38 State Lie. No.: 482623 City Bus. Lie. No. 615 Print Name on License: Brudvik, Inc Phone: 760-320-4429 Address: 600 S. Eugene Rd, Palm Springs, CA, 92264 Every county or city which requires the issuance of a permit as a condition precedent to the construction, alteration, improvement, demolition or repair of any building or structure shall require that each applicant for the permit sign a declaration under penalty of perjury verifying workers' compensation coverage or exemption from coverage as required by Section 19825 of the Health and Safety Code. I, hereby affirm under penalty of perjury one of the following declarations: ❑ I HAVE AND WILL MAINTAIN A CERTIFICATE TO SELF INSURE for worker's compensation as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I HAVE AND WILL MAINTAIN WORKERS' COMPENSATION INSURANCE, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Everest National Insurance Company Policy No. 7600016212161 ❑ I CERTIFY that in the performance of work for which this permit is issued, I SHALL NOT EMPLOY ANY PERSON, in any manner so as to become subject to the worker's compensation laws of California, and agree that if 1 should become subject to the worker's compensation provisions of Section 3700 of the Labor Code, I shall for with comply with those provisions. Contractor or Agents Signature: Date: Disclosure Form City of Palm Springs, CA Page 1