Loading...
HomeMy WebLinkAbout2016-1873 (3) - 248 Orchid Tree LnCity of Palm Springs BUILDING PERMI1* Building Address: 248 Orchid Tree Ln Date 03/21 /2019 Case No.: Submitted Owner Address Rod Ramsour 248 Orchid Tree Ln Palm Springs CA Contractor Address Renova Energy 75181 Mediterranean Ave Palm Desert CA Architect Address Engineer Address Lot # Block # Tract 70 + ENCHANTHOMES Lot Size Zone2 10400 Building Sq. Ft. New Use of building sfd Fire Sprinkler Units Describe work in detail: 29 PV Panel, 9.9 M System. Special Conditions: Garage/Carport Permit Type PhotoVoltaic Valuation 39092.00 Permit Kim Floyd Technician Phone 503 314 1935 Phone Lic. Number 760 568 3413 910836 Phone Phone Parcel Number 602-091-013 Occupancy Roofed Patio/Porch Permit Fees Paid 433.61 Remodeled Area Const. Type Fixture Units DO NOT CONCEAL OR COVER ANY CONSTRUCTION UNTIL THE WORK IS INSPECTED IMPORTANT The issuance of this permit shall not be held to be an approval of the violation of any provisions of any city or county ordinance or state law. Inspections of work are subject to an approved set of plans being on the job. Changes to plans are not to be made without permission of the Building and Safety Divisions. The owner and/or, contractor is responsible for establishing all property lines. All utilities must be underground. This permit will expire if work is not started in 180 days or if more than 180 days elapses between inspections. I certify that I am fapiikar with all requirements of the City of Palm Springs as they apply to this permit and understand that these requirements must be completed prior fin ecti n and that no certification of occupancy will be issued until such time as these requirements are met. I certify that I have read this ap i atib'n state hat th formation is true and correct. 121119uAl�.� OWNER/CONTRACTOR/AGENT DATE This is a building permit when properly filled out, signed and validated, and is not transferable. ISSUED BY Finaled �• �� PERMIT NUMBER 201 9-1103 • • INSPECTION INFORMATION No work shall be concealed without a signature by the inspector. The approved plans and this card must always be available to the inspector. Preserve this record. Every permit issued shall become invalid after 180 days unless a required inspection has been approved. Furthermore, permits expire when more than 180 days has elapsed from the date of the last approved reqiured inspection. CONSTRUCTION HOURS Weekdays 7am to 7pm Saturdays 8am to 5pm Sundays & Holidays Not Permitted JOB NOTES:' SEPARATE PERMIT IS REQUIRED FOR MAIN SERVICE PANEL UPGRADES OR CHANGE OUTS. JOB CARD Project address:248 Orchid Tree Ln Permit #: 2019-1103 Inspection hours 8AM - 4PM Monday - Thursday Final Inspection request line (760) 323-8243 Building Department (760) 323-8242 Building Department Fax (760) 322-8342 PHOTOVOLTAIC INSPECTIONS �poLse City of Palm Springs 3200 East Tahquitz Canyon Way Palm Springs, CA 92262 �`?FOA�, Phone: Bldg: 760-323-8242 Eng: 760-323-8253 Fax: See Below ACCOUNT: Renova Energy 75181 Mediterranean Ave Palm Desert CA 92211 Phone: 760 5618 3413 Oid Receipt Summary Page 1 of 1 DATE 3/26/2019 PERMIT NUMBER 1 2019-1103 248 Orchid Tree Ln Palm Springs, CA Date Reference Number Invoice Number FeeCat Description Status Amount 3/26/2019 2019-1103 19-1341 001-32201 PHOTOVOLTAIC SOLAR Paid (-) 224.98 3/26/2019 2019-1103 19-1341 001-32204 PERMITPROCESSINGFEE Paid (-) 36.94 3/26/2019 2019-1103 19-1341 001-32219 S.B. 1473 Paid O 2.00 3/26/2019 2019-1103 19-1341 001-34301 INTERNAL PLAN REVI EW(IN-HOUSE) Paid (-) 87.31 3/26/2019 12019-1103 19-1341 001-34308 Microfilm Paid (-) 15.15 3/26/2019 2019-1103 19-1341 001-37111 SMIP1 Paid (-) 3.90 3/26/2019 2019-1103 19-1341 261-32214 Technology Fee Paid (-) 63.33 Date InvoiceNum Status Payment Amount 3/21/2019 19-1341 Original Due 433.61 3/26/2019 19-1341 Paid Check (-) 433.61 Total Paid 433.61 Building Fax #: 760-322-8342 Engineering Fax #: 760-322-8325 0 o�4A`,M PERMIT APPLICATION Department of Building & Code Enforcement N 3200 East Tahquitz Canyon Way, Palm Springs CA 92262 PO Box 2743, Palm Springs CA 92263 kOA•ORAT[O p'` Tel 760.323-8242 ■ Fax 760.322.8360 ■ TDD 760.864.9627 C`��rFORa�P www.palmsi2rings-ca.aov Date: 3/18/19 Solar Photovoltaic Systems Only Permit # ,201 9- 1163_ Project Address: �d�`'Al � 00 248 North Orchid Tree Lane Owners Name Rod Ramsour Phone: 503-314-1935 Owners Address: 248 North Orchid Tree Lane Contractor: Renova Energy Corp. Phone 760-568-3413 Address: 75181 Mediterranean Ave., Palm Desert, CA 92211 Lic. # 910836 Engineer: Matthew De La Torre permits@renovaenergy.com Phone 760-568-3413 Total KW: 9.9 kW AC # Panels: 29 String or Micro AC MODULES Valuation $39,092.00 Description: Roof Top Mounted Solar PV Installation. Expedited Submittal Packages In Person Electronic Submittal • Three Complete sets of plans 11x 17 • Single PDF Plan file • Cut sheets on inverters, combiner boxes • Cut sheets on inverters, combiner boxes and disconnects and disconnects. • Worksheet (only for String systems) • Worksheet (only for String systems) Complete submittal requirements listed on www.palmsprinqsca.gov under Building I certify that the information supplied on this application is true and correct. Christian Cordero Contractor Signature City of Palm Springs Department of Building & Safety 3200 East Tahquitz Canyon Way, Palm Springs, CA 92262 PO Box 2743, Palm Springs, CA 92263 Tel: 760.323-8242 1 Fax: 760.322.8360 ( TDD: 760.864.9527 www. palmspringsca.gov CERTIFICATION OF SMOKE & CARBON MONOXIDE (CO) ALARMS AND WATER -CONSERVING PLUMBING FIXTURES In an effort to enhance life safety within existing dwellings, California Residential Code (CRC) Sections R314 and R315 and California Building Code (CBC) Section 420.6, require that smoke alarms and CO alarms be installed when alterations, repairs or additions are performed and the valuation of the work exceeds $1,000. Generally, the alarms are required to be hard -wired, have battery backups, and be interconnected; however, they may be solely battery operated under certain conditions (please check with an Inspector for exceptions). The alarms are required to be installed in the following locations: ➢ Smoke alarms in all sleeping rooms, ➢ CO alarms in all sleeping rooms within which fuel -burning appliances are installed, ➢ Smoke alarm and CO alarm in area preceding sleeping rooms (such as a hallway), and ➢ Smoke alarm and CO alarm on each story level of the dwelling including basements and habitable attic rooms. Additionally, all plumbing fixtures within the dwelling unit are required to comply with the applicable retrofit provisions of California Civil Code Section 1101, Chapter 4 of the California Plumbing Code and Chapter 4 of the California Green Building Standards Code. The plumbing fixtures shall have maximum flow rates as listed below: ➢ Toilets —not more than 1.28 gallons of water per flush ➢ Urinals —not more than 0.5 gallons of water per flush ➢ Showerheads — not more than 2.0 gallons of water per minute (gpm) ➢ Faucets — not more than 1.2 gpm for bathroom lavatories and 1.8 gpm for kitchens The alarms and plumbing fixtures are required to comply with the above when requesting the final inspection. Please make sure that an adult is present to allow an Inspector within the home to verify compliance with the above requirements. If for some reason an adult will not be present, you may opt to complete the Installation Certification below. Please leave the signed Certification with the job card. For the property located at 248 N Orchid Tree Ln. Palm Springs, CA 92262 , and under permit number i6/f "/ r-11 , I hereby certify that the required smoke alarms, carbon monoxide alarms, and/or plumbing fixtures have been installed as listed above. Jb- Signature Rod Ramsour Print Nov 7, 2019 Date Relationship to Project (please check one): 0 Owner', ❑ Agent for Owner ❑ Licensed Contractor ❑ Agent for Licensed Contractor If "Licensed Contractor" or "Agent for Licensed Contractor" is checked, please complete the following: Company Name 04/02/2019 Page 1 of 1 Contractor's State License Number City of Palm Springs PV Electrical Information Worksheet Property Address: 248 N ORCHID TREE LN PV System Information (Note: Provide input data from manufacturer's cut sheets. PV module and inverter manufacturer's cult2sheet must be attached.) SUNPOWER 9 1 Module: (Mrf and model#) SPR-X22-360-D-AC Total Modules: 29 No. of Modules in Parallel 8 No. of Circuits 1 Max Module Watts (Pmax): 360 Watts Max. Voltage (Vmp): N/A Volts Max Current (Imp): N/A Amps Open Circuit Voltage (Voc) N/A Short Circuit Current (1sc) N/A Max DC System Voltage (Vdc) N/A Max Series Fuse (OCPD) N/A Total Circuit Length (array to inverter) N/A Conductor Resistance Factor (fVkft) .786 Temperature Correction Factor .58 Conduit Fill Factor .8 Inverter: (Mfr and model#) N/A Max Dc Input Volts N/A Continuous Power (w) N/A Max AC Output 1.33 Point of Connection: Main Service OCPD: 200 Amps Bus Bar Rating: 200 Location of Main OCPD: (Center or at top or bottom of Service panel) TOP (Note: Center Fed Panels may not take advantage of the 120% PV Array Calculations and Verification of Conductor Sizes Rated DE Power of System = (Module wattage) x (# of models in array) _ Rated MPP Voltage = (Vmp) x (# modules in series) _ Rated MPP Current = (Imp) x (# panel circuits) = Max DC System Voltage = (Voc) x (# modules in series) x (Temp correction) _ Wire Size from Modules to Inverters (DC): Maximum PV Circuit Current: Source Currents (Ise) x (125%) Output Circuit: (Source circuit current) x (# parallel circuits) Conductor Ampacity & Overcurrent Rating: Source Circuits: (Max Circuit Current) x (125%) Output Circuit: (Max circuit Current) x (125%) Derated Ampacity (Conditions of Use Factors) Source Circuits = 360 X 29 = 10440 N/A X N/A X N/A X N/A X N/A X N/A X N/A J X N/A J X (Continuous current / (temp correction) x (Conduit fill) 19.95 / ( 58 X Voltage Drop(%) = (Imp) x (Wkft) x (Total circuit length /1000) / Array Vmp ( N/A X N/A X Minimum Conductor Size (using CEC Table 310.16) AWG Co er) 15.96 1.25 _ 19.95 Overcurrent Device Rating: (Max Circuit current) x (125%) X — Conductor Size from Inverter to Service Panel (AC): Total AC Output of PV System (Cannot exceed IOKW for expedited review) = (Inverter AC output) X (Nominal Voltage) N/A amps X N/A volts = N/A Watts. Maximum Circuit Current = Max inverter Output / Nominal AC Voltage Amps N/A Conductor Ampacity & Overcurrent Device Rating: Iverter Output = (max circuit current) X (125%) 15.96 X 1.25 = 20 Amps Rounded up Minimum Conductor Size (using CED Table 310.16) Overcurrent Device Rating: AWG (Copper) (maximum circuit current) X (125%) 15.96 X 1.25 = 19.95 Amps AC Point of Connection to main Service Panel Maximum Allowable OCPD (bus bar rating) X (100% or 120%) Maximum PV OCPD: (Max allowable OCPD) — (Main OCPD) Maximum Size Inverter: (Max PV OCPD) X (0.8) Grounding Electrode Conductor: 200 X 1.2 — 240 Amps 240 -- 200 — 40 (CEC Sec 690.47(c) (2) and 250.166) DC N/A AWG AC AWG This worksheet must accompany the permit application and construction plans for submittal and review. Acknowledgement: Contractor acknowledges that they are responsible for the accuracy of the information and calculations, and that the PV system design, equipment selection, and sizing of conductors, conduits, and overcurrent protection devices are in compliance with all current applicable State and local codes. Contractor: 'Llri FN$URY Date: 3/14/2018 Ramsour 12611 RESIDENTIAL. INSTALLATION AGREEMENT HOMEIMPROVEMENT CONTRACT EFFECTIVE DATE. February 23, 2018 FILE NO: 12611 ....... _....... .. _. ...._ .......... ._..._,_. .... _--....... .._..... .......... __ i "CUSTOMER": "CONTRACTOR": i I Rod Ramsour I i Renava Energy Corp. � 248 N Orchid Tree Ln i 75-181 Mediterranean Ave. Palm Springs, CA92262' Palm Desert, CA 92211 ! II j Telephone: 503-314-1935 California Contractors State License (� System size kilowatts (DC): 10.44 Board Contractor License #910836 Service Number: 3 D43-393D D7 Meter number: 222020-009457 y This is the address to which the Notice of Cancellation should be mailed: Date customer signed this agreement' I Consultant MC i Customer is entitled to a completely filled -in copy of this Agreement signed by both parties before work may be started. E _......... ... _.._. } 1. Project. Name and Address of the Project: ( 2. Construction Funds. Name and address of the Ramsour/Johnston Residence construction lender (if any), 248 N Orchid Tree Ln Palm Springs, CA 92262 I � i _._._..... ...... ...... __. ..._ _.__...._...._._._ 3 Description of the Project and Description of the Significant Materials to be Used and Equipment to be I Installed. Contractor will install the following solar and electrical and sustainability equipment at the Project address set forth above. Contractor will secure and pay for all required building permits, but Customer will f pay assessments and charges required by public agencies and utilities for financing or repaying the cost of sewers, storm drains, water service and other utilities (including sewer and storm -drain reimbursement charges, revolving fund charges, hookup charges, and the like), as applicable. Contractor will be responsible j for filing rebate and incentive forms with agencies on Customer's behalf, where applicable. _ .._....__ ........ _ ._.._ _.._ _...... _ .. _, . __....._ ......_. ...._.. . l _ t i I Corporate Headquarters i 75-181 Mediterranean Ave. ( Palm Desert CA 92211 ���� � «��@ ����`�����w��^� �e'r�~��-9 kx���w ���� ��� 12611 � 6 and Business and Professions Code §7159(e)(6)8)). Customer has the right to cancel this Agreement within 3business days. You may cancel bye`maiUng, mailing, faxing or delivering a written notice to Contractor at Contractor's place of business by midnight of the third business day after you received asigned and dated copy ofthis Agreement. Include 'Your name, your address, and the date you received the signed copy ofthis Agreement. Ifyou cancel, Contractor must return toyou anything you paid within 1Odays ofreceiving the notice ofcancellation. For your part, you must make available to Contractor at the Project site, in substantially as good condition as you received it, any goods delivered under this Agreement; or, you may, if you wish, comply with Contractor's instructions on how to return the goods mtContractor's expense and risk. If you de make the goods available to Contractor and Contractor does not pick them up within 20 days of the date of your notice of cancellation, you may keep them without any further obligation, |fyou fall tomake the goods available toContractor, or ifyou agree toreturn the goods tQ Contractor and fail to do so, then you remain liable for performance of all obligations under the contract. [NWITNESS WHEREOF, the parties hereto have executed this Agreement asefthe Effective Date above, DATED: February 23, 2018 Print Name ofCustomer DATED: February I3,2O18 By: , n.-44U)a Name: ete Lewis Title: Vice PresW^ President of Sales Marketing Installation Agreement SCE Residential 8 CVSTOM[R|N