HomeMy WebLinkAbout2016-3347$ City of Palm Springs
BUILDING PERMI
Building Address: 3712 Camino San Simeon
Date 09/08/2016
Case No.:
Submitted
Owner
Address
Phone
Luke Waldo
3712 Camino San Simeon 323 791 7018
Palm Springs CA
Contractor
Address
Phone
Hosopo Corporation DBA
7100 W Florida Ave
951 926 1176
Horizon Solar Power
Hemet CA
Architect
Address
Phone
Engineer
Address
Phone
Lot # Block #
Tract
Parcel Number
40 +
VISTADELCIELO
680-061-010
Lot Size
Zone
Occupancy
10126
Building Sq. Ft.
Garage/Carport
Roofed Patio/Porch
New
Use of building Permit Type
sfd Electric Service Upgrade
Fire Sprinkler Units Valuation Permit Fees Paid
1800.00 125.32
Describe work in detail:
Upgrade main service panel to 200 Amps
Special Conditions:
Permit Kim Floyd
Technician
Lic. Number
1004233
Remodeled Area
Const. Type Fixture Units
DO NOT CONCEAL OR COVER ANY CONSTRUCTION UNTIL THE WORK IS INSPECTED
IMPORTANT
The issuance of this permit shall not be held to be an approval of the violation of any provisions of any city or county ordinance or state law.
Inspections of work are subject to an approved set of plans being on the job. Changes to plans are not to be made without permission of the Building and
Safety Divisions.
The owner and/or contractor is responsible for establishing all property lines. All utilities must be underground.
This permit will expire if work is not started in 180 days or if more than 180 days elapses between
inspections.
I certify that I am familiar with all requirements of the City of Palm Springs as they apply to this permit and understand that these requirements must be
completed prior to final inspection and that no certification of occupancy will be issued until such time as these requirements are met. I certify that I have
read this application and state that the information is true and correct.
OWN ER/ZrONTRACTOR/AG ENJ/ ' IDA I t/
This is a building permit when prop r y filled out, signed and validated, and is not transferable.
ISSUED BY Finaled l
PERMIT NUMBER 2016-3347
•
INSPECTION INFORMATION
No work shall be concealed without a signature by the
inspector.
The approved plans and this card must always be
available to the inspector. Preserve this record.
A permit shall expire and become null and void if
substanial work is not commenced within 180 days, or
if the work is suspended or abandoned for a period of
180 days. If the work is progressing but approaching
the end of the 180 day period from the last recorded
day of a passed inspection, a progress inspection must
be obtained to keep an active permit.
CONSTRUCTION HOURS
Weekdays 7am to 7pm
Saturdays 8am to 5pm
Sundays & Holidays Not Permitted
JOB NOTES:
JOBCARD
Project address: 3712 Camino San Simeon
Permit #: 2016-3347
Inspection hours 8AM - 4PM Monday - Thursday
Inspection request line (760) 323-8243
Building Department (760) 323-8242
Building Department Fax (760) 322-8342
ELECTRIC SERVICE UPGRADE INSPECTIONS
Meter Release (Q
Final
OQ pA04 S
A�
ti Z
U �
a C'10FORN\P.
Date 9/7/16
*BUILDING PERMIT APPIATION
Project Address 3712 E Camino San Simeon
Owner's Name Luke Waldo
Owner's Address 3712 E Camino San Simeon
Plan Check Deposit Fees:
Building:
Fire:
Assessor's Parcel #
Phone # 323-791-7018
Contractor's Name ric' �)% Phone # 951-662-8769 Llc# 47-227-'4-
Contractor's Address425 W La Cadena # 21 iOOlam
Architect's Name
Architect's Address
Engineer's Name
Phone #
Phone #
Lic.#
Lic.#
Engineer's Address
CONTACT PERSON Holly Thompson Address 7100 W Florida Ave
PHONE 951-537-6859 FAX
EMAIL holly.thompson@horizonsolarpower.com
Business License. # , Expiration Date Lot Size (sf.)
Building Use Type of Const. Occupancy Groups) Sprinkled
Project Square Footage: Building Garage Carport Patio (type)
Project Description (N) 200A Main Panel
Total Value of Work $1800.00
WHERE INDICATED BY A CHECK, SUBMIT 4 SETS
(Minimum size of plans *18 x 24" Minimum scale W=1';Maximum size of plans 40" x 36")
❑ Complete Application.
❑ Plot Plan with lot square footage.
❑ Drainage Plan: show lot corner elevations.
❑ Structural Calculations, if applicable
(wet -stamped and signed)
❑ Floor Plan, dimensioned. Door & Window
Schedule
❑ Framing Plan with sections and elevations
❑ Truss Calculations and layout as applicable
(wet -stamped and signed.)
❑ Foundation Plan
❑ Electrical Plan/Load Calculations
❑ Health Department approval
Bldg. Plan Check #.
❑ Waste, Drain & Vent Isometric
❑ Gas/Water Piping Isometric (dimensioned layout)
❑ Details showing compliance with accessibility.
requirements
❑ Site Plan showing parking for persons with
disabilities and path of travel to building entrance
❑ Title 24 (Energy) — 2 sets/ Lighting Compliance
Forms
❑ Manufacture's brochure for HVAC equipment
❑ Mech. Plan / Duct Schematic, equipment location
❑ Fireplace Specifications, if applicable
❑ Planning / Fire / Engineering approval
❑ Fire Sprinkler plans (required at time of submittal)
Planning Case #
Signature
Lighting Loads
horilb ffi+rrtd )
_ SEP 0 8 2016
R P '0 W
CITY OF PAf_M SPRING
DEFT OF BUILDING 8 SAI
710%. Florida Ave I Hemet, CA 92545
951.926.1176 1 HorizonSolarpower.com
Luke Waldo - RESIDENCE LOAD CALCULATIONS
000 PUT ADDRESS, HERE, CA 9100
220-12
Living area sq. ft. 1800 x 3 volt-amperes per sq. ft.
5400
VA
220.52A
Two small appliance circuits (required) x 1500 VA
3000
VA
220.52B
Laundry circuit (s) 1 x 1500 VA
1500
VA
220.52A
Additional small appliance circuit(s) 2
x 1500 VA
3000
VA
Lighting Load Subtotal =
12900
VA
220.42
First 3000 volt-amperes of lighting loads @ 100%
3000
VA
From 3001 to 120,000 VA @ 9900
35%
3465
VA
Remainder over 120,000 VA @ 0
25%
0
VA
Lighting Load Total Volt -Amperes =
6465
VA (A)
Appliance
Loads
220.55
Household Cooking Applicances
(Use table 220.55) # of Cooking Appliances
1
1000'
VA
Cooking Units Total Volt -Amperes =
1000'.
VA (B )
220.53
Appliance Loads (nameplates)
Microwave 1 x 1500 VA
1500
VA
Compactor 1 x 1200 VA
1200
VA
Dishwasher 1 x 1200 VA
1200
VA
Disposal 1 x 600 VA
600
VA
Central Vacuum 0x 1800 VA
0
VA
Breakers
Misc ` 30 A
5760
VA
Misc 20 A
3840
VA
Appliance Subtotal =
14100
VA
Appliance Subtotal ( 14100 x 75% correction*) =
10575
VA (C )
*Correction applied when there are >_ 4 units. If < 4, record subtotal at 100%
Major Appliance Loads
220.54 Dryer
0 VA (D )
422.10A Water Heater
A
0 VA (E )
220.14 SUM of Pool/Spa motor loads per nameplate Misc. Major Loads
Breaker
A
0 VA (F)
A
0 VA (F)
A
0 VA (F)
A
0 VA (F)
Total Volt -Amperes of((A)(B)(C)(D)(E)(F))+240
75.17 Amps(G)
220.14C A/C or heating loads
AC 1
50 A
A
A
A
Total =
9600 VA ( 240 Volts x 125%) 32.00 Amps (H )
Total Service ( H) + ( G) =
107.17 AMPS
L&#vy �oLvoora'P.
Leroy Polvoorde
a
BrighterTomorrow.
1004233, C46
cv
IL 0
Service Section Upgrade -Change out
Conduit & Conductor Size
Service
Section Size Sub
a� Panes
Size
Conductor Size
Conduit Size
Grounding Electrode Conductor Size —/ (250,66)
— Size Water Bond or Augment to Electrode Size_ (250.66)
Size Bonding Conductor for Gas Piping System f— (250.12Z)
A minimum of two 8' driven ground rods spaced at least 6' apart shall be installed in the
absence of concrete encased electrode (uffer).
Table 250.66 GroandingElectrode Conductor for
Alternating -Current Systems
She of Largest Ungrounded
Service -Entrance Size of Grounding
Conductor or Equivalent Electrode Conductor
Area for Parallel (AWG/kemil)
Condactorm ANVG/kcmil)
Aluminum Aluminum
or Copper- or
,Glad Copper -
Copper Aluminum Copper Clad
Aluminum
b
2 or smaller 1/0 or smaller 3 6
1 or 11010 or 3+0 6 4
10 or 3/0 4/0 or 250 4 2
OVea3/0 Overiau _ i?v
through 310 through 500
Over 35o Over 500 Uo 3 0
through 600 through 900
Over 600 Over 900 10 4,0
cfirongh L100 through 1750
Over 1100 Over 1750 3/0 250
Notes:
t
L. Where multiple sets of service -entrance conductors are used
as permitted in 230.40, Exception No. 2, the equivalent sue of
the largest service-entraace conductor shall be determined by
the largest sum of the areas of the corresponding conductors of
each set.
2. Where there are no service -entrance conductors, the
grounding electrode conductor size shall be determined by the
equivalent size of the largest service -entrance conductor
irequired for the load to be served.
-This table also applies to the derived conductors of separately
Table 250.122 Minimum Size Equipment Grounding
Conductors for Grounding Raceway and Equipment
Size CA'SYG or kcmil)
Rating or Setting of
Automatic Overcurrent
Device in Circuit Ahead
Aluminum
of Equipment, Conduit,
or Copper -
etc., Not Exceeding
Clad
(Amperes)
Copper
Aluminum*
15
14
12
20
12
10
30
10
8
40
10
8
60
10
8
100
8
6
200
6
4
300
4
400
3
1
500
2
1'0
600
1
2,0
800
1/0
3,!0
1000
2/0
4'0
1200
3/0
250
1600
4/0
350
2000
250
400
2500
350
600
3000
400
600
4000
500
5000
700
1200
6000
800
1200
Note; Where necessary to comply with 250.4(A)(5) or (B)(4),
the equipment grounding conductor shall be sized larger than
mivon �n 14ti¢ fnhle