Loading...
HomeMy WebLinkAbout2016-3312�`�` City of Palm Springs BUILDING PERMIT �cr�otBuilding Address: 3712 Camino San Simeon Date 09/07/2016 Case No.: Submitted Owner Address Phone Luke Waldo 3712 Camino San Simeon 323 791 7018 Palm Springs CA Contractor Address Phone HosopoCorporationDBA 7100 W Florida Ave 951 926 1176 Horizon Solar Power Hemet CA Architect Address Phone Engineer Address Phone Lot # Block # Tract Parcel Number 40 + VISTADELCIELO 680-061-010 Lot Size Zone Occupancy 10126 Building Sq. Ft. Garage/Carport Roofed Patio/Porch New Use of building Permit Type SFD PhotoVoltaic Fire Sprinkler Units Valuation Permit Fees Paid 21000.00 368.13 Describe work in detail: 25 PV Panel Array- 6.875kW Solar System Permit Taja Sims Technician Lic. Number 1004233 Special Conditions: SEPARATE PERMIT IS REQUIRED FOR MAIN SERVICE PANEL UPGRADE. Remodeled Area Const. Type Fixture Units DO NOT CONCEAL OR COVER ANY CONSTRUCTION UNTIL THE WORK IS INSPECTED IMPnRTONT The issuance of this permit shall not be held to be an approval of the violation of any provisions of any city or county ordinance or state law. Inspections of work are subject to an approved set of plans being on the job. Changes to plans are not to be made without permission of the Building and Safety Divisions. The owner and/or contractor is responsible for establishing all property lines. All utilities must be underground. This permit will expire if work is not started in 180 days or if more than 180 days elapses between inspections. I certify that I am familiar with all requirements of the City of Palm Springs as they apply to this permit and understand that these requirements must be completed prior to final inspection and that no certification of occupancy will be issued until such time as these requirements met. I certify that I have read this application and state that the information is true and correct. /ZI-14 OVWtR/CONTRACTOR/AUNT DATE ISSUED This is a building permit when properly filled out, signed and validated, and is not transferable. F i n a I e d PERMIT NUMBER 2016-3312 • • INSPECTION INFORMATION No work shall be concealed without a signature by the inspector. The approved plans and this card must always be available to the inspector. Preserve this record. A permit shall expire and become null and void if substanial work is not commenced within 180 days, or if the work is suspended or abandoned for a period of 180 days. If the work is progressing but approaching the end of the 180 day period from the last recorded day of a passed inspection, a progress inspection must be obtained to keep an active permit. CONSTRUCTION HOURS Weekdays 7am to 7pm Saturdays 8am to 5pm Sundays & Holidays Not Permitted JOB NOTES: SEPARATE PERMIT IS REQUIRED FOR MAIN SERVICE PANEL UPGRADES OR CHANGE OUTS. Project address:3712 Camino San Simeon Permit #: 2016-3312 Inspection hours 8AM - 4PM Monday - Thursday Inspection request line (760) 323-8243 Building Department (760) 323-8242 Building Department Fax (760) 322-8342 PHOTOVOLTAIC INSPECTIONS 0 OF PALM 9p CENED V-7 /16 • CIL FORN�P • ate C.sty of Pai G & gQ .F BUILDING PERMIT APPLICATION Project Address 3712 Camino San Simeon Owner's Name Luke Waldo Owner's Address 3712 Camino San Simeon Plan Check Deposit Fees: Building: Fire: _ Assessor's Parcel # (nb0nQWJ -0Io Phone # 323-791-7018 Contractor's Name Hosopo Corp DBA Horizon Solar Power Phone # 951-926-1176 Llc# 1004233 Contractor's Address 7100 W Florida Ave Architect's Name Phone # Lic.# Architect's Address Engineer's Name Phone # Lic.# Engineer's Address CONTACT PERSON Holly Thompson Address 7100 W Florida Ave PHONE 951-537-6859 FAX EMAIL holly.thompson@horizonsolarpower.com Business License. # , Expiration Date Lot Size (sf.) Building Use Type of Const. Occupancy Group(s) Sprinkled Project Square Footage: Building Garage Carport Patio (type) Project Description 6.875 kW roof mount PV install, 25 modules, 25 powtiTofal Value of Work $ 21,000 WHERE INDICATED BY A CHECK, SUBMIT 4 SETS (Minimum size of plans *18 x 24" Minimum scale W=1';Maximum size of plans 40" x 36") ❑ Complete Application. ❑ Plot Plan with lot square footage. ❑ Drainage Plan: show lot corner elevations. ❑ Structural Calculations, if applicable (wet -stamped and signed) ❑ Floor Plan, dimensioned. Door & Window Schedule ❑ Framing Plan with sections and elevations ❑ Truss Calculations and layout as applicable (wet -stamped and signed.) ❑ Foundation Plan ❑ Electrical Plan/Load Calculations ❑ Health Department approval Bldg. Plan Check # in I�?5j12 Planning Case #. ❑ Waste, Drain & Vent Isometric ❑ Gas/Water Piping Isometric (dimensioned layout) ❑ Details showing compliance with accessibility. requirements ❑ Site Plan showing parking for persons with disabilities and path of travel to building entrance ❑ Title 24 (Energy) — 2 sets/ Lighting Compliance Forms ❑ Manufacture's brochure for HVAC equipment ❑ Mech. Plan / Duct Schematic, equipment location ❑ Fireplace Specifications, if applicable ❑ Planning / Fire / Engineering approval ❑ Fire Sprinkler plans (required at time of submittal) Signature OWNER / BUILDER DECLARATION hereby affirm under penalty of perury that I am exempt from the Contractor's License Law for the following reason (Section 70 31,5. Business and Professions Code: Any city or county which requires.wpermit to construct, aster. Improve, demolish, or repair any Structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9 commencing with Sec. 7000 of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a perm;t subjects the applicant to a civil penalty of not more than five hundred dollars (5500).) Please check one of the following: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044 of the Business and Profession Code. The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.) ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044 of the Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractor's License Law.) ❑ I am exempt under Sec. of the Business and Professions Code for this reason: Owner Signature: Date: LICENSED CONTRACTORS DECLARATION! I hereby affirm under penalty of perjury that t am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. The following applies to S contractors only:.. I understand the limitations of Section 7057 related to my ability to take prime contracts or subcontracts Involving specialty trades. License Class: �_1cq�- . State Lic. No.: tciG 33 City Bus. Lic. No. Print Name on License:, Cam DSIA • Phon Address: ��C; L'o I f:,l Or i a Yvll�- e1/11 SO 1 Every county or city which requires the issuance of a permit as a condition precedent to the construction,. alteration, improvement, demolition or repair of any building or structure shall require that each applicant for the permit sign a declaration under penalty of perjury verifying workers' compensation coverage or exemption from coverage as required by Section 19825 of the Health and Safety Code. I, hereby affirm under penalty of perjury one of the following declarations: I HAVE AND WILL MAINTAIN A CERTIFICATE TO SELF INSURE for worker's compensation as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I HAVE AND WiLL MAINTAIN WORKERS' COMPENSATION INSURANCE, a's required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carder: 1 �� �(�YJQ \ 1_ n s �� �' � � Policy No. 6L ,l LE � Q9 j (A6 13 I CERTIFY that in the performance of work for which this permit is issued, I SHALL NOT EMPLOY ANY PERSON, in any manner so as to become subject to the worker's compensation laws of California, and agree that if I should become subject to the worker's compensation provisions of Section 3700 of thft Labor Code, I shall for with comply with those provisions. Contractor or Agents Signature: v • City of Palm Springs PV Electrical Information Worksheet Property Address: 3712 E. CAMONO SAN SIMEON,PALM PV System Information (Note: Provide Input data from manufacturer's cut sheets. PV module and inverter manufacturer's cut sheet must be attached.) Module: (Mrf and model#) Canadian Solar,C56K-275M Total Modules: 25 No. of Modules in Series: 13 No. of Strings 2 Max Module Watts (Pmax): 275 Watts Max. Voltage (Vmp): 31.3 Volts Max Current (Imp): 8.8 Amps Open Circuit Voltage (Voc) 38.3 Short Circuit Current (Isc) 9.31 Max DC System Voltage (Vdc) 500 Max Series Fuse (OCPD) 15 A Total Circuit Length (array to inverter) 80 Conductor Resistance Factor (fl/kft) 0,778 Temperature Correction Factor 55 Conduit Fill Factoi 0.8 Inverter: (Mfr and model#) Solar Edge, SE6000A-US Max Dc Input Volts 500 Continuous Power (W) 7500 Max AC Output 2° Point of Connection: Main Service OCPD: 35 Amps Location of Main OCPD: (Center or at top or bottom of Service panel) Top Fed (Note: Center Fed Panels may not take advantage of the 120% rule) I PV Array Calculations and Verification of Conductor Size! Rated DE Power of System = (Module wattage) x (# of models in array) = 275 X 25 = 6875 Rated MPP Voltage = (Vmp) x (# modules in series) = solar X edge = 350 Rated MPP Current = (Imp) x (# panel circuits) = solar X edge = 15 Max DC System Voltage = (Voc) x (# modules in series) x (Temp correction) = solar X edge X regulated = 500 Size from Modules to Inverters (DC): PV Circuit Current: Source Currents (Isc) x (125%) Output Circuit: (Source circuit current) x (# parallel circuits) ductor Ampacity & Overcurrent Rating: Source Circuits: (Max Circuit Current) x (125%) Output Circuit: (Max circuit Current) x (125%) Ampacity (Conditions of Use Factors) Circuits = (Continuous current / (temp correction) x (Conduit fill) 15 X 1.25 - 18.75 18.75 X 18.75 X 1.25 = 23.44 18.75 X 1.25 = 23.44 X Voltage DropM _ (Imp) x (fi/kft) x (Total circuit length /1000) / Array Vmp ( 15 X 0.778 X Minimum Conductor Size (using CEC Table 310.16) 1 8 j AWG (Copper) Device Rating: (Max Circuit current) x (125%) X 1 1.25 = Conductor Size from Inverter to Service Panel (AC): Total AC Output of PV System (Cannot exceed 10KW for expedited review) _ (Inverter AC output) X (Nominal Voltage) 1 25 7amps X 240 volts = 6000 Watts. Maximum Circuit Current = Max inverter Output / Nominal AC Voltage 7500 = 31.25 Amps 240 for Ampacity & Overcurrent Device Rating: Output = (max circuit current) X (125%) 25 X 1.25 = 35 Amps rounded up Minimum Conductor Size (using CED Table 310.16) AWG (Copper) Overcurrent Device Rating: (bus bar rating) X (125%) 1 25 X 1.25 = 31.25 AC Point of Connection to Main Service Panel Maximum Allowable OCPD (bus bar rating) X (100% or 120%) Maximum PV OCPD: (Max allowable OCPD) - (Main OCPD) Maximum Size Inverter: (Max PV OCPD) x (0.8) Grounding Electrode Conductor: (CEC Sec 690.47( c) ( 2) and 250.166) 225 X 1.2 - 270 Amps 270 200 - 70 40 X DC =AWG AC=AWG This worksheet must accompany the permit application and construction plans for submittal and review. Acknowledgement: Contractor acknowledges that they are responsible for the accuracy of the information and calculations, and that the PV system design, equipment selection, and sizing of conductors, conduits, and overcurrent protection devices are in compliance with all current applicable State and local codes. Contractor: HOSOPO, CORP. Date: 9/5/2016