Loading...
HomeMy WebLinkAbout2016-3176 (2)DocuSign Envelope ID: EE2855F4-8CD1-4BA4-85D2-9A76FOOE5743 Palm Springs ..,Y— L4LD1NG---P-E--R-M1T Building Address: 3793 Date Palm Trl Date 09/17/2020 Case No.: Permit Reynaldo Bermudez Submitted Technician Owner Address Phone Jerry Carlson 3793 Date Palm Trl 510 410 7800 Palm Springs CA Contractor Address Phone Lic. Number Tesla Energy (DBA) 3055 Clearview Way 714 274 7895 888104 San Mateo CA Architect Address Phone Engineer Address Phone Lot # Block # Tract Parcel Number 130 30058 669-690-028 Lot Size Zone Occupancy 8179 Building Sq. Ft. Garage/Carport Roofed Patio/Porch Remodeled Area New Use of building Permit Type Const, Type Fixture Units sfd PhotoVoltaic Fire Sprinkler Units Valuation Permit Fees Paid 11424.00 499.75 Describe work in detail: 16 PV Panel Array (5.44 kW) Special Conditions: Dig. Sub. DO NOT CONCEAL OR COVER ANY CONSTRUCTION UNTIL THE WORK IS INSPECTED IMPORTANT The issuance of this permit shall not be held to be an approval of the violation of any provisions of any city or county ordinance or state law. Inspections of work are subject to an approved set of plans being on the job. Changes to plans are not to be made without permission of the Building and Safety Divisions. The owner and/or contractor is responsible for establishing all property lines. All utilities must be underground. This permit will expire if work is not started in 180 days or if more than 180 days elapses between inspections. I certify that I am familiar with all requirements of the City of Palm Springs as they apply to this permit and understand that these requirements must be completed prior to final inspection and that no certification of occupancy will be issued until such time as these requirements are met. I certify that I have read Is 90"Mla* nd state that the information is true and correct. Lr;- SEAL f'� 10/16/2020 27E38DDK420... OWNER/CONTRACTOR/AGENT DATE ISSUED BY Finaled , - /! ! e 6219 This is a building permit when properly filled out, signed and validated, and is not transferable. PERMITNUMBER 2020-2893 INSPECTION INFORMATION No work shall be concealed without a signature by the inspector. The approved plans and this card must always be available to the inspector. Preserve this record. Every permit issued shall become invalid after 180 days unless a required inspection has been approved. Furthermore, permits expire when more than 180 days has elapsed from the date of the last approved reqiured inspection. CONSTRUCTION HOURS Weekdays 7am to 7pm Saturdays 8am to 5pm Sundays & Holidays Not Permitted JOB NOTES: SEPARATE PERMIT IS REQUIRED FOR MAIN SERVICE PANEL UPGRADES OR CHANGE OUTS. JOB CARD Project address:3793 Date Palm Trl Permit #: 2020-2893 Inspection hours 8AM - 4PM Monday - Thursday Inspection request line (760) 323-8243 Building Department (760) 323-8242 Building Department Fax (760) 322-8342 PHOTOVOLTAIC INSPECTIONS Final: /( /0 Zn" t'S 0 0 Date 9/9/20 City of Palm Springs Permit Application Solar Photovoltaic Systems Only Permit # Project Address: 3793 Date Palm Trail Owners Name: Jerry Carlson Phone: 510 410-7800 Owners Address: 3793 Date Palm Trail Contractor: Tesla - Crystal Braun Phone: 951-660-3516 Address: 1755 Iowa Ave. Ste.B Riverside CA. 92507 Lic. #: 888104 Engineer: Phone: Contact Email: cbraun tesla.com Contact Phone: 951-660-3516 Total KW: 5.44 # Panels: 16 String or Micro: String Valuation: 11 424 Description: Expedited Submittal Packages In Person Electronic Submittal • Three Complete sets of plans 11 x 17 • Single PDF Plan file • Cut sheets on inverters, combiner boxes • Cut sheets on inverters, combiner boxes and disconnects and disconnects. • Worksheet (only for String systems) • Worksheet (only for String systems) Complete submittal requirements listed on www. alms rin sca. ov under Building I certify that the information supplied on this application is true and correct. Contractor Signature 0 • City of Palm Springs PV Electrical Information Worksheet Property Address: 3793 Date Palm Trail, Palm Springs, CA 92262, US PV System Information (Note: Provide input data from manufacturer's cut sheets. PV module and inverter manufacturer's cut sheet must be attached.) Module: (Mrfand model#) Hanwha Q-CELLS 340 Total Modules: 16 No. of Modules in Series 16 No. of Strings 1 Max Module Watts (Pmax): 340 Watts Max. Voltage (vmp): 33.94 Volts Max Current (imp): 10.02 Amps Open Circuit Voltage (voc) 40.66 Short Circuit Current (Ise) 10.52 Max DC System Voltage (Vdc) 480 Max Series Fuse (OCPD) 40 Total Circuit Length (array to inverter) 50 Conductor Resistance Factor (Mft) 1.24 Temperature Correction Factor 0.87 Conduit Fill Factor 0.80 Inverter: (Mfr and model#) SE760OH-US Max Dc Input Volts 11800 Continuous Power (w) 7600 Max AC Output 7600 Point of Connection: Main Service OCPD: 200 Amps Bus Bar Rating: 200 Location of Main OCPD: (Center or at top or bottom of Service panel) Bottom (Note: Center Fed Panels may not take advantage of the 120% rule) PV Array Calculations and Verification of Conductor Sizes Rated DE Power of System = (Module wattage) x (# of models in array) _ Rated MPP Voltage = (Vmp) x (# modules in series) _ Rated MPP Current = (Imp) x (# panel circuits) _ Max DC System Voltage = (Voc) x (# modules in series) x (Temp correction) = 340 X 16 = 5440 33.94 X 16 = 543.04 10.02 X 10.02 40.66 X 16 X 87 = 557.64 Wire Size from Modules to Inverters (DC): Maximum PV Circuit Current: Source Currents (Isc) x (125%) 15 X 1.25 = 18.75 Output Circuit: (Source circuit current) x (# parallel circuits) 1a.75 X Conductor Ampacity & Overcurrent Rating: Source Circuits: (Max Circuit Current) x (125%) 16.75 X 1.25 = 23.44 Output Circuit: (Max circuit Current) x (125%) 18.75 X 1.25 = 23.44 Derated Ampacity (Conditions of Use Factors) Source Circuits = (Continuous current / (temp correction) x (Conduit fill) Voltage Drop(%) = 10.02 ]/( 0.87 X (Imp) x (Mft) x (Total circuit length /I000) / Array Vmp ( 10.02 X 1.24 X 50/1000 ) / 407.28 = 0.0015 Minimum Conductor Size (using CEC Table 310.16) #10 AWG Co er) 18.75 1.25 _ 23.44 Overcurrent Device Rating: (Max Circuit current) x (125%) X 0 • Conductor Size from Inverter to Service Panel (AC): Total AC Output of PV System (Cannot exceed IOKW for expedited review) = (Inverter AC output) X (Nominal Voltage) 32 amps X 2ao volts = 7sso Watts. Maximum Circuit Current = 7600 = 31.66 Max inverter Output /Nominal AC Voltage � Amps 240 Conductor Ampacity & Overcurrent Device Rating: Iverter Output = (max circuit current) X (125%) 31.ss X 1.25 = 4o Amps Rounded up Minimum Conductor Size (using CED Table 310.16) Overcurrent Device Rating: #s AWG (Copper) (maximum circuit current) X (125%) 32 X 1.25 = ao Amps AC Point of Connection to main Service Panel Maximum Allowable OCPD (bus bar rating) X (100% or 120%) Maximum PV OCPD: (Max allowable OCPD) — (Main OCPD) Maximum Size Inverter: (Max PV OCPD) X (0.8) Grounding Electrode Conductor: zoo X 1.20 = 2ao Amps 240 "" 200 = 40 40 X (CEC Sec 690.47(c) (2) and 250.166) DC #s AWG AC #6 AWG This worksheet must accompany the permit application and construction plans for submittal and review. Acknowledgement: Contractor acknowledges that they are responsible for the accuracy of the information and calculations, and that the PV system design, equipment selection, and sizing of conductors, conduits, and overcurrent protection devices are in compliance with all current applicable State and local codes. Contractor: Date: r� u YSTEM DISCLOSURE printe°d on the front pa nstallation of a solar ei oT for the solar energy syste plicable) is: $8,473.07 cludi ential ing and energy / To make a complaint against a contractor who installs' 'this system and/or the home improvement salesperson who sold this system, contact the Contractors State License Board (CSLB) through their website at www.csib.ca.gov (search: "complaint form"), by telephone at 800-321-CSLB (2752), or by writing to P.O. Box 26000, Sacramento, CA 95826. If the attached cons you have a Three-D Professions Code ( canceling the conti your contract. 111 iegotieted at the contractor's place incel the contract, pursuant to Bus 7159, as noted below. For further d otice of Cancellation, whichmust k e-Day Right to You, the buyer, have the right to cancel this contract within three business days. You may cancel by e-mailing, mailing, faxing, or delivering a written notice to the contractor at the contractor's place of business by midnight of the third business day;after you received a signed and dated copy of the contract that includes this notice. Include your name, your address, and the date you received the signed copy of the contract and this notice. This document was developed California Public Utilities Comi Solar Purchase 4181693 the California Contractors State License I ness and Professions Code section 7169. 6 in This disclosure is designed to helpyou understand the key terms of your purchase of a solar electric system ("System"). iubstitule4or your purchase contract ("Contract"), loan or any pth&rd uments,,�associated with this it is nof transaction. n e is �bbject to the terms of your Con rac Read all documents cai Ify so you fully understand the transaction. For more information on becoming a smart solar consumer please vislit www.seia.o[g/edasumers. Provider: Tesia, Inc. Installer: Tesia Energy OpeMitions Jerry Carlson S stem Installation Address: RZ A�' 'Deer Creek Road Inc. k, y Palo,� dA`64'304 Address: 901 Page Avenue 3793 Date Palm Trail, Tel.: 888-518-3752 Fremont, CA 94538 Palm Springs, CA 92262 License # (if applicable): CA CSLB Tel.: 888-765-2489 Customer Mailing Address: 949283 State/Co,(Jinty Contractor License #: 3793 Date Palm Trail, Email: CA CSkP`b88104 Palm Springs, CA 92262 energycustomersupport@tesla.com Email: Email: carlson.jerry@comcast, net AM Purchase Price Your purchase price: $8'373. List of any credits, incentives or rebates inc1luded'in the above purchase price: $100.00 orrebates orcan fully use them. legal professional for further information. at the commencement of installation: $( following building inspection: $8,373.07 Your system; Financing ofSystem imUNKNOWN hoProvider NOTiofinanced, carefully read any agreements and/or diso�s'sureforms provided hyyour lender. This statement does not contain the terms of your financing agreement. If you have any questions about your financing arrangement, contact your finance provider and read all financing disclosures ba/oneai, Installation Timing Approximate Start Date: 7-QOdays from the Approximate Completion Date: 7-90 days fr, .nterconnection Approval The estimated size of your System is.4.0E. Estimated gross annual electricity pi6dlucti Estimated System Lifetime: '30,ypars solar Purchase Disclosur( the Agiteement is signed. n application. kilowatt-hours (kVVh)from your System Estimated annual electricity p System location on your prop Connectivity: The SystehiWIll At the time of installation, you to suchcredlit are set by your of the system may resuftlnjo ,reassessing the con jract rate ueho natural aging ofthe System: 0.5% e connected to the electric grid. al utility WILL credit you for excess energy your Syst diction. Your utility offers a net energy metering polic nmission. Changes in net energy rqetennqpo utility bill savings than estimated orne at all; Tesla �& Repairs IS included for 20 years from the Installer. You are der state statute or res during the life be responsible for rform the following system maintenance: • Shade Management: Shading on you/ solar display dramatically reduces electricity production. Keep trees or other tall plants trimmed hoprevent shade on,your system • Panel Cleaning: Cleaning your panels of debris mprove Your system performance. Flushing the panels f/ the ground with awater hose can let more sunlight penetrate through the glass cover. , "System repairs" refers tnactions needed If System repairs ARE included, the,,66'yei Solar Panels: at least 12 years Inverter: at least 10 years Please check the Manufacturer's if itismalfunctioning. System repairs ARE hardware component ofyour System (i coverage period ofother hardware for the labor/workmanship for intract for additional information about any wm farrahtie� for hardware are not required ioind rights, or obligations under this Agreement to E ill be notified if this will change the address or, Your io6f IS warranted against leaks from the system installation for the fi� Performance orProduction Guarantee Provider is not providing you with a performance or,production guarantee. Taxes � You are responsible for property taxes on may result from entering the Cont Utility and Electricity Usage/Saythigs You HAVE been provided with a inc If provided, the savings estimate War> c ig codes, location, system size, 'govIern mE on the System,,,�Jrlstallatilpn and equipment. or/workmanship. I Your Provider may assign or ate, successor, partner or purchaser. If such a number t6�,use for system maintenance or Consult atax professional tounderstand any tax based oh,Y,6ur purchase. � aoedon: Estimates ofannual utility rate increases, .which can beaffected byshading, The savings estimate bxyou Your system will last: 301yp� It is important to are estimates only, Your actual cu savings.in eein tight to Cancel oyou have under state orlocal law, you HA aodays nf 9/5/202012:28:57PK8+00:00 this agreement without penalty notifying Provider inwriting stthe SEW\Solar Business Code Provider DOES abide by and agrees to be bound by SEIA's Solar Business Code and its complaint resolution process For more information about the SBA8o!ar Business, Code and complaint resolution process, please visit Customer's Initials here JC This "Agreement" below Price Shee electronic accept; the Testa Enerav 51041 Is Purchase & Home Improvement Agreement entity ("Tesla", "we" "us" or "our") identified belw conditions, and is effective on the date you agr shall supersede all prior existing agreements be Tesla, Inc. of 3500 Deer Creek Road, Palo Alto, 888-765-2489 CA CSLB 949283 Tesla Energy Operations, Inc. of CA CSLB 888104 Tesla Solar System 4.08 kW and Other Fees System Pric Taxes Contract Pri Cre Cre Energy Products V8.0, 7/17/2020 Tessa, inc.. 4181693 CA 94538 J (1) the ant (by sla for $1804.00 $1,148.00 $410.00 $4,838.00 3.07 1 Customer's In The schedule of progress payments must specifically describe each phase of work, including the type and amount of work or services scheduled to be supplied in each phase, along with the amount of each proposed progress payment. IT IS AGAINST THE LAW FOR A CONTRACTOR TO COLLECT PAYMENT FOR WORK NOT YET COMPLETED, OR FOR MATERIALS NOT YET DELIVERED. HOWEVER, A CONTRACTOR MAY REQUIRE A DOWNPAYMENT. The pricing in this Agreement is valid for 30 days after 9/5/2020. If you don't sign this Agreement and return it to us on or prior to 30 days after 9/5/2020, Tesla reserves theright to reject this Agreement unless you agree to our then current pricing. You, the buyer, may cancel this transaction at any time prior to midnight of the third business day after the date' of this transaction. See the attached notice of cancellation form for an explanation of this right. If you are financing your System;throtagh one of our financing partners, the timing and amount of your',payments (and any applicable interest accrued) will be subject $o the terms and conditions of your agreement with your financier. If your financier fails to make payment on your behalf; -6r your financing is terminated by you or your financier, you will remain obligated to make payment under the terms of this Agreement. days from the date of this Agreement 7-90 days from the date of this Agreement Your signature Tesla, Inc. Jerry Carlson Name: Jerry Carlson Date: 9/5/2020 12:28:57 PM +00:00 Energy Products V8.0, 7/17/2020 Tesla, Inc. 4181693 122 Name: Carl Peterson Title: Senior Director, Residential Energy E ;o• .,.�M rr�� City of Palm Springs u M Department of Building ik Safety 3200 East Tahquitz Canyon Way, Palm Springs, CA 92262 PO Box 2743, Palm Springs, CA 92263 " Tel: 760.323-8242 ( Fax: 760.322.8360 1 TDD: 760.864.9527 • ��"O"��' wwwmalmsorinasca.aov CERTIFICATION OF SMOKE & CARBON MONOXIDE (CO) ALARMS AND WATER -CONSERVING PLUMBING FIXTURES In an effort to enhance life safety within existing dwellings, California Residential Code (CRC) Sections R314 and R315, and California Building Code (CBC) Section 420.6, require that smoke alarms and CO alarms be installed when alterations, repairs or additions are performed and the valuation of the work exceeds $1,000, Generally, the alarms are required to be hard -wired, have battery backups, and be Interconnected; however, they may be solely battery operated under certain conditions (please check with an Inspector for exceptions). The alarms are required to be installed in the following locations: > Smoke alarms in all sleeping rooms, ? CO alarms in all sleeping rooms within which fuel-buming appliances are installed, .- Smoke alarm and CO alarm in area preceding sleeping rooms (such as a hallway), and 9 Smoke alarm and CO alarm on each story level of the dwelling including basements and habitable attic rooms. Additionally, all plumbing fixtures within the dwelling unit are required to comply with the applicable retrofit provisions of California Civil Code Section 1101. Chapter 4 of the California Plumbing Code and Chapter 4 of the California Green Building Standards Code. The plumbing fixtures shall have maximum flow rates as listed below: Toilets— not more than 1.28 gallons of water per flush Urinals —not more than 0.5 gallons of water per flush Showerheads — not more than 2.0 gallons of water per minute (gpm) Faucets — not more than 1.2 gpm for bathroom lavatories and 1.8 gpm for kitchens The alarms and plumbing fixtures are required to comply with the above when requesting the final inspection. Please make sure that an adult is present to allow an Inspector within the home to verify compliance with the above requirements. If for some reason an adult will not be present, you may opt to complete the Installation Certification below. Please leave the signed Certification with the job card. INSTALLATION CERTIFICATION For the property located at `� �� � and under permit number , I hereby certify that the required smoke alarms, carbon monoxide alarms, and/or tubing ff)�dure7 been installed as fisted above. r Signature riot Dale to Project (please check one): owner 0 Agent for Owner ❑ Licensed Contractor ❑ Agent for Licensed Contractor If "Licensed Contractor" or "Agent for Lice Contractor" is checked, please complete the foll ng: Company Name Contra uW3 State Lice umber Oa102r-0! h Page 1 of I