HomeMy WebLinkAbout3815 E Calle De Carlos_Business Lic Inspection; BUSINESS LICENSE TRACKING SHEET
Business Address: 3815 Calle de Carlos
Planning Zoning
Fire Department
Code Enforcement
Building Department
Violations
C/Inspect. OK to issue:
Contact Inspector:
Department Comments:
❑Yes ❑ No
❑Yes ❑No
❑Yes ❑ No
QYes ❑ No
❑Yes Q No
❑✓.Yes❑No
Date
Date
Date
Date 3/26/14
Date 3/26/14
Date 3/26/14
Initials
Initials
Initials
Initials KF
Initials KF
Initials KF
at 760-323-8242 Ext:
UCERTIFICATE OF INSPECTION — CITY OF PALM SPRINGS
This is to certify that the building or tenant space, hereby described has been
inspected. The following occupancy group is authorized:
3815 Calle de Carlos
Address of Property:
Occupancy Group: R-2 Occupancy Load: Number of Units5
Business Name: Paul Kakuschky
Business Type:
Apartments
Business License Number & Date Issued:
Legal Description / A.P.N. of Property: 680-045-004
2001277/March 3, 2014
Tenant or Owner of Property: Paul Kakuschky
Mailing Address: 2424 East Powell Road, Palm Springs, CA 92262
Building Official: Building Inspector:
�icaro, MCP
Date:'
Keith Fox
f A,L4r j
E�
Y N
Business Address:
BUSINESS LICENSE BUILDING INSPECTION r
3815 Calle de Carlos
Date:
3/26/14
Paul Kakuscflky
Business Marne: _ _
Inspector: Keith Fox
TABLE 7 - 3 UNIFORM PLUMBING CODE
Drainage Fixture Unit Values (DFU) Page 62 - 2000 Edition
Inch
i1/-1 m4 32
t-112 40
2 50
Min. Sae
2-1/2 65
3 80
Trap and
Plumbing Appliance, Appurtenance or Fixture Trap Arm?
Private
Public
Assernbly$
Bathtub or Combination Bath/Shower........................................1-1/2"
2.0
2.0
-.)I
Bidet.......................................................................................1-1/4'
1.0
Bidet- ........................... ...................................
.............................I.......1-1/2"
2.0
Clothes Washer, domestic, standpipes ....................................... 2"
3.0
Dental Unit, cuspidor............................................................. .....1-t/4
1.0
1.0
Dishwasher, domestic, with independent drain..........................1-1/22
2.0
2.0
2.0
Drinking Fountain or Watermler (per head).............................1-114"
0.5
0.5
1.0
Food -waste -grinder, commercial ................................................ 2"
3.0
3.0
Floor Drain, emrgency............................................................. 2"
0.0
0.0
Floor Drain (for additional sizes see Section 702)...................... 2"
2.0
2.0
2.0
Shower single head trap............................................................. 2"
2.0
2.0
2.0
Multi -head, each additional.................................................... 2"
1.0
1.0
1.0
--►
Lavatory, single...........................................................................1-1/4"
1.0
1.0
1.0
"--r
Lavatory in sets of two or three...................................................1-1/2'
2.0
2.0
2.0
Washfouta............................................................................1-1/2"
3.0
2.0
Washfountalnin.. .2"
3:0
3.0
MobileHome, trap ......................... :............................................ 3"
12.0
Receptor, indirect waster-3.......... ....... ..................................... ..1-1/2"
See footnote 1,3
Receptor, indirect waster-4......................................................... 2"
See footnote IA
Receptor, indirect wastet............................................................ 3"
See footnote 1
SINrs
�►
Bar........................................................................................1-1/2-
1.0
Bar....................................... ................................................... 1-1/2'2
2.0
2.0
Clinical.............. ..................................:............................. 3'
6.0
6.0
Commercial with food waste ......... ........................................... 1-1/2"2
3.0
3.0
Special Purpose..... ........................................ ...........................1-1/2'
2.0
3-0
3.0
SpecialPurpose....................................................................... 2"
3.0
4.0
4.0
Special Purpose ..................... ....... 3'
6.0
6.0
-->•
Kitchen, domestic.............................................................1.1/2"2
2.0
.2.0
�t
(with or without food -waste -grinder and/or dishwasher)
Laundry ............. ............................................. ................... .....1-1/2'
'2.0
2.0
2.0
(with or without discharge from a clothes washer)
Service or Mop Basin .............................. A.............................. 2-
3.0
3.0
Service or Mop Basin.............................................................. 3'
3.0
3.0
Service, flushing rim ................... ... 3"
..........................................
6.0
6.0
Wash, each set of faucets.......................................................
2.0
2.0
Urinal, integral trap 1.0 GPF2..................................................... 2"
2.0
2.0
5.0
Urinal, Integral trap greater than 1.0 GPF................................... 2"
2-0
2.0
6.0
Urinal, exposed trap......................................................1-102
2.0
2.0
5.0
^-►
Water Close1,1.6 GPF Gravity Tanks .... ............................... 3'
3.0
4.0
6.0
Water Closet, 1.6 GPF Fiushometer Tanks........:... .................... 3-
3.0
4.0
6.0
-01
Water Closet, 1.6 GPF Flushometer Valves ............................... 3"
3.0
4.0
8.0
-0-
Water Closet, greater than 1.6 GPF. Gravity Tanks ................... 3"
4.0
6.0
8.0
Water Closet, greater than 1.6 GPF Flushometer Valves........... 3"
4.0
6.0
8.0
1'. Indirect wash receptprs $W be sized based on the IM drainage cepwily of the fixtures that drain therein to, in accordance *M Table 7.4.
-►
2. Provide a 2" (81 mm) minimum drain.
3. For refrigerators, coffee um% water stations. and sfmifar low dernands.
4. For corrrnercfsl ainlcs, doh+washers, and s6nilar moderato or heavy demands.
/.S-ll�Jul
c+.
S. Buildings having a cloeres washing area with clothes washers In a battery of three (3) or more clothes washers shalt be rated at six (6) Mdum units each for
purposes d sizing common horizontal and verticar drainage piping.
6. water etasets shelf be computed as six 18) f6dure units when determining septic tank sizes based on Appard6r K of this Code.
7. Trap sites shall rot be increased to the pent where the nxhrro discivuge may be inadegra;i8 to maintain their self -scouring properties.
8. Assembly (PubAc Use (See Tabs 4.1)).