HomeMy WebLinkAbout2019-2433 signedOIrA(Mr'0I= City of Palm Springs
BUILDING PERMIT
Building Address: 190 W San Marco Way
Date 06120/2019
Submitted
Owner
Chris Taylor
Commctor
Roof Asset Management
Architect
Engineer
Case No
Address
Phone
same
760 813 9999
Palm Springs CA
Address
Phone
72056 NorthshoreSt Ste B
760 813 9999
1000 Palms CA
Address
Phone
Address
Lola all is Tract
18 THECOLONY
Lot Sue Zone
Building Sq. Ft. Garage/Carport
Permit was R.
Technician
LIE. Number
677708
Phone
Parcel Number
504-124-006
Occupancy
Roofed Patio/Porch Remodeled Area
Use of building Permit Type Const. Type Fixture Units
aid Re -Roof
Fire Sprinkler Units Valuation Permit Fees Pad
10960.00 210.77
Describe work in detail'.
Clean off roof and install new foam and coating system CRRCa 0626-0010
SEPERATE PERMIT AND INSPECTION REQUIRED FOR REMOVAL AND
REINSTALLATION OF MECHANICAL EQUIPMENT AND PHOTOVOLTAIC SYSTEMS.
Special Cond lens:
Rooftop mechanical equipment must be on minimum six inch
high sheet metal covered platforms or other approved
support. Condensate lines must be in hard copper.
Any hot tar roofing operation must comply with the California
Fire Code and requires a permit from the Fire Department.
W NOT CONCEAL OR COVER ANY CONSTRUCTION UNTIL THE WORK IS INSPECTED
IMPORTANT
The issuance of this permit shall not be held to be an approval of the violation of any provisions of any city or county ordinance or state low.
Inspections of work are subject to an approved Set of Plana being on the job. Changes to plans are not to be made without permission of the Building and
Safety Divisions.
The owner anchor Contractor is responsible for establishing all property lines. All utilities must be underground
This permit will expire if work is not started! In 180 days Or if more than 180 days elapses between
inspections.
I certify that I am familiar with all requirements of the City of Palm Springs as they apply to this permit and understand that these requirements must be
Completed prior to final Inspection and that no certification of Occupancy will be issued until such time as these requirements are met. I certify that I have
read this application and slate that the information is true and correct.
61201 i9 An
OWNER/ NTRACTOWAGENT DATE IS UED By Finaled �Lo
This sa IIding permitwhen property filled out. signed and validated and is not transferable.
PERMITNUMSER 201 433
INSPECTION INFORMATION
No work shall be concealed without a signature by the
inspector.
The approved plans and this card must always be
available to the inspector. Preserve this record.
Every permit issued shall become invalid after 180
days unless a required inspection has been approved.
Furthermore, permits expire when more than 180 days
has elapsed from the date of the last approved
inspection.
CONSTRUCTION HOURS
Weekdays 7am to 7pm
Saturdays Sam to Spm
Sundays & Holidays Not Permitted
JOB NOTES:
JOB CARD
Project address: 190 W San Marco Way
Permit #: 2019-2433
Inspection hours SAM -4PM Monday -Thursday
Inspection request line (760) 323-8243
Building Department (760) 323-8242
Building Department Fax (760) 322-8342
RE -ROOFS INSPECTIONS
Cleanoff/Primer / Flash ing: ZS
DO NOT ROOF UNTIL THE ABOVE IS SIGNED
Roof Final:
SEPERATE PERMIT AND INSPECTION REQUIRED FOR REMOVAL
AND REINSTALLATION OF MECHANICAL EQUIPMENT AND
PHOTOVOLTAIC SYSTEMS.
°�,..,,, City of Palm Springs • 10aid Receipt Summary
3200 East Tahqultz Canyon Way
Palm Springs, CA 92262 Page 1 of 1
'"�v Phone: Bldg: 780-323-8242 Eng: 70D-323-8253 DATE 6/20/2019
Fax: See Below
ACCOUNT:
Roof Asset Management
Ste B
72056 Nonhshom St
1000 Palms CA 92270
Phone: 760 813 9999
PERMIT NUMBER 1 2019-2433
190 W San Marco Way
POR LOT 16 MB 019/006 THE COLONY TRACT
Palm Springs, CA 92262
Dele
Reference Number
Imoiee Number
FeeCat
Description
Star"
Amount
6202019
20192433
19-2838
001-32201
PERMf7PROCESSINGFEE
Pad
(-)36-94
6202019
2019-2433
19-2838
001-32201
RERCOFFEES
Pad
(-)14960
6202019
2019-2433
192838
001-32219
S.B. 1473
Pad
(-) 1.00
6202019
2019-2433
10.2838
001-34308
Mlaoll"
Pad
(-) 4.05
620I2019
2019.2433
19-2838
001-37111
SMIPI
Pad
(-) 1.42
620.2019
2019.2433
19-2838
261-32214
Technology Fee
Pad
(-)17.76
Date
ImroiceNum
Status
Payment
Amount
8202019
194838
Original Due
210.R
6Q0/2019
19.2838
Pad
Check4982
(-)210.77
Total Paid 210.77
Building Fax #: 760-322-8342
Engineering Fax If: 760-322-8325
d, BUILDING PERMIT APPLICATION
FOR BLOCK WALLS, POOLS, REROOFS, & REPIPES
DATE: 6 1�,o / 17
Project /
Owner's
Owner's
Phone
Contractor's Name Aon
-(
ASS"F�Y /1']9ni c�-��
Phone # XC�93-9999
Contractor's Address 7�56
/f/orry�sli0rl
S4. 4k �
LIc.#-.G/77708'
Engineer's
Phone
Engineer's Address Lic#
CONTACT PERSON Tall.( bt r, Of Address Phone #
Walls — Height of Wall Length of Wall Front Set Back
Re -roofs —S.F. of Roof ILT00 Wt. of Material ES (ICBO) Report! UL Listing
Project Description Total Value of Work $ 10/ 960 As
.. i ., , .,
C"C.' 0<16 -polo
WHERE INDICATED BY A HC ECK SUBMIT 3 SETS
(Minimum size of pool plans 11" X 17" Minimum scale Y==1')
❑ Plot Plan with lot square footage. ❑ Waste, Drain & Vent Isometric.
❑ Planning/Eng. Department Approval. ❑ Water Piping Isometric, dimensioned.
❑ Structural Calculations, if applicable. ❑ Gas Piping Isometric: Show BTU ratings of
❑ Roof or Truss Eng., if applicable. each appliance on all branches, distance
❑ Plan for Pool with Wet Stamp from Engineer. and placement of longest run & total BTU for
entire system.
SITE PLAN FOR POOLS MUST BE COMPLETE: MUST SHOW ENTIRE SITE, PROPERTY LINES,
BUILDING FOOTPRINT, NORTH ARROW, LEGAL DESCRIPTION AND PROPER ADDRESS.
XIs70RIC SRE PREBERVATON BOARD
��f,���7`ERTIFICATE OF APPROVAL '�77''��
De1NPf"�tlgmns� Caret RmriQ
CIUSS Lj No a0A�A" f
��i
City of Path Springs
Department of Building S Safety
1� �� 3200 East Toni Canyon Way, Palm Sprigs, CA 92262
PO Box 2743, Palm Splinge, CA 92283
prrrosr.- Ted 700.323-82421Faz: 760.322B38O I TDO: 7W.BB4.9527
CERTIFICATION OF
SMOKE 8 CARBON MONOXIDE (CO) ALARMS AND WATER -CONSERVING PLUMBING FIXTURES
Ij In an effort to enhance life safety within existing dwellings, Ceafomla Residential Code (CRC) Sections R314
and R315. and California Builoktg Code (CBC) Section 420.6. require that smoke alarms and CO alarms be
:hatelad wsten alterations, repairs or additional are performed and the valuation of the work exceeds $1,000
6 3enerally, the alarms are required to be hand -wined, have battery backups. and be inter =rre kid: however
'hey .may be solely battery operated under certain conditions (please check with an inspector for exceptions)
The alarms are required to be installed in the following locations -
Smoke alarms In all sleeping rooms,
C O alarms in all sleeping rooms whhin which fuel -burning appliances are Instahed
inokc alarm and CO alarm In area preceding sleeping rooms (such as a haaway anti
Smoke alarm and CO alarm on each story awl of the oweking Including tormenters and Macleod
attic rooms.
_onelly, as plumbing fixtures within the dwelkig unit are required to comply wth me applicable reVOOI
r ovswns Of California Clvll Code Section tl01. Chapter 4 of the California Plumbing Ccde and Chapter 4 of
ire Califomb Green Building Standards Cork. The plumbing axtures shall have maxknun flow rates as lilted
below:
Tott@U- not more than 1.20 gallons of water per nush
Urinals -not more than 0.5 gallons of water partition
Showerma i ds -not more than 2.0 gallons of water per m null (gpm)
• Faucets -not more than 1.2 gion for bathroom lavatories and 18 gri for kitchens
-.re alarms and plumbing (uiures are required to comply with the above when requesting the that hat inns
rare sure that an adult a present to allow an inspector within the home to verify-omWtanoe win.
s;ooernards. If forsane reason an adult will not be present, you may opt to Mortis s the Installm
.;at.on below. Please Lave the signed Certification with the job cord.
INSTALLATION CERTIFICATION
",a arapeny located al 190 '�. 141%1 hill W4`1 Pq L.I Slikitl nd under perms
-t r 1 hereby certify that the required smoke alarms, ra•bon moncxitle alarms, and/or
ti^n IneWad As listed above.
_ t— cN2ti T9Y�e2 9 7f /9
snter ant
. :nship to Project (pease check one):
X C Agent for Owner ❑ Licensed Contractor ❑ Agent for Licensed Contractor
Conifackre or -Agem far Licensed Contractor' is cnecked, protests complete the (Wowing:
eelMy Phi ,eae4111s nee Ni
-- page I of t
R0613ASSET
M A N A G E M. E N T
mv.
June 13, 2019
Chris Taylor
1901N San Marco Way
Palm Springs, CA 92262
Subject: 194W San Marco Way, Palm Springs, CA 92262
Installation of a polyurethane foam and coating system.
Dear Mr. Taylor,
Thank you for the opportunity to submit a proposal for the installation of a new roof system at the
above referenced property. The scope of work and associated costs are as follows:
GENERAL
This proposal and contract is made between Roof Asset Management Inc. (Contractor) and the person
(s) or entity named above (Owner) or authorized agent. The contractor shall be responsible for
performing the following unless expressly stated to the contrary:
DESCRIPTION
A. The Contractor shall furnish all labor, materials and equipment required to perform the scope ow
work as specified. Contractor's license, permits and insurance certificates required to complete
the project will be maintained.
B. If any unforeseen or unexpected conditions are encountered during the work, the contractor
shall notify the owner immediately and the owner will negotiate a written change -order to
address the unexpected condition whether it be an increase or decrease to the original contract
amount.
C. The Contractor Is to be given reasonable access and staging areas to complete the project.
D. Contractors scope of work shall not include the identification, detection, abatement,
encapsulation or removal of asbestos or similar hazardous substances including mold, mildew
and infestation of rodents. If any such hazardous products, materials, substances or conditions
are encountered by Contractor or any others rforming work at the jobsite, and Contractor
ROOD I I
760181319999
72056 NORTHSHORE ST. SUITE B THOUSAND PALMS. CA 92276
email: office@RAMroofmgmt.com
Chris Taylor
June 13, 2019
Page 2
determines that they present a hazard to its employees, Contractor shall have the right to
discontinue the work and remove its employees from the jobsite until such products, materials,
substances or conditions and any hazards connected with are located and abated, encapsulated
or removed. The contractor shall receive an extension of time to complete Its work and
compensation for delays encountered as a result of such conditions and remedy. Due to the
possibility of mold, mildew and rodents being present before, during or after our work, Owner
agrees to hold Contractor harmless, and shall indemnify Contractor harmless for any mold or
rodent related claims in the future.
If a dispute arises between Contractor and Owner with respect to any matters related to the
contract or breach thereof, the dispute shall be decided by arbitration administered by and in
accordance with the Construction Industry Arbitration Rules of the American Arbitration
Association or through such arbitration procedures as the parties agree. This contract shall be
specifically enforceable under prevailing arbitration law. The decision and award by the
arbitrators shall be final and judgement may be entered upon it in any court having jurisdiction
thereof.
F. Should suit be brought to enforce or interpret any part of the Agreement, the "prevailing Party'
shall be entitled to recover, as an element of cost of such suit and not as damages, reasonable
attorney's fees to be fixed by the court. The "Prevailing party'shall be entitled to recover its cost
of the suit, regardless of whether such suit proceeds to final judgment.
SCOPE OF WORK
1. Existing roof system to be broomed clean.
2. Prime entire roof deck.
3. Install new perimeter edge metal.
4. Spray apply polyurethane foam at a thickness of 1.5" (+or—Xu). Only 31b. density foam will be used.
Additional polyurethane foam will be added to the low areas to help minimize ponding. Some
ponding will remain.
5. Apply the first application of coating at a rate of 1.50 gallons per 100 square feet.
6. Apply top layer of mating at a rate of 1.50 gallons per 100 square feet yielding a TDM thickness of.
22-24 Top mat color to be White.
7. Embed granules in the wet top coat material at a rate of 50 pounds per 100 square feet.
CONTRACT AMOUNT: $20,960.00 (Ten Thousand Eight Hundred Sixty Dollars)
ROOFF A S I I