Loading...
HomeMy WebLinkAboutItem 1D ARC SR packet 211 Ridge Mtn KL ARCHITECTURAL REVIEW COMMITTEE MEMORANDUM DATE: OCTOBER 21, 2024 NEW BUSINESS SUBJECT: A MAJOR ARCHITECTURAL APPLICATION BY KOVAC DESIGN STUDIO FOR STEPHEN WHYTE, OWNER, FOR APPROVAL OF A SINGLE-FAMILY RESIDENCE ON A 2.34-ACRE HILLSIDE LOT LOCATED AT 211 RIDGE MOUNTAIN DRIVE; ZONE: OPEN SPACE-20; GENERAL PLAN: ESTATE RESIDENTIAL, APN: 513-570-001, PLANNING CASE AR-2024-0049 / AMM-2024-0007 (KL) FROM: Department of Planning Services PROJECT DESCRIPTION: This is a request for approval of a Major Architectural Application for a 7,900-square-foot single family residence on a hillside lot. The proposed dwelling is comprised of seven, single-story “pavilions” that step with the topography of the site. The total overall height is 27 feet at the north side of the proposed dwelling which requires approval of an Administrative Minor Modification (“AMM”) for total height greater than 18 feet (the findings for the AMM are included herein). RECOMMENDATION: That the Architectural Review Committee approves the application, subject to conditions. BELOW AN CONCEPTUAL RENDERING SHOWING THE HOME AS VIEWED FROM THE SOUTHEAST Architectural Review Committee Memo Case #AR-2024-0049 / AMM-2024-0007; 211 Ridge Mountain Drive October 21, 2024 – Page 2 of 7 BUSINESS PRINCIPAL DISCLOSURE: The property is titled in the name of the property owner’s trust. A Public Integrity Disclosure form is attached. ISSUES: The hillside lot on which this project is proposed has significant grades requiring stepped building pads and retaining walls. The street elevation at the proposed driveway is at elevation 635 and the uppermost finished floor is at elevation 694 (a 59 -foot grade change). The lowest elevation on the lot is approximately 615’ and the highest elevation is 710’. BACKGROUND INFORMATION: Related Relevant City Actions May 9, 2024 Pre-submittal Case Precon-2024-0003 for the proposed project was processed by the Planning Dept. Neighborhood Meeting/Neighborhood Notice June 27, 2024 Written notice of receipt of the application was sent to owners of property adjacent to the subject site pursuant to Zoning Code Section 93.13.00 (B,1,b). October 8, 2024 Notice mailed by staff to adjacent property owners notifying that the subject project would be reviewed by the Architectural Review Committee on October 21, 2024. October 16, 2024 The surrounding neighborhood organizations within a mile of the site were sent notice that the proposed project would be reviewed by the Architectural Review Committee. STAFF ANALYSIS: Site Area Net Acres 2.34 Acres (101,930 square feet) (Minimum lot size for the O-20 zone is 20 acres; the parcel is a legal, non-conforming lot of record. General Plan and Zoning Designations General Plan Designation Permitted Density Compliance Estate Residential 2 du/ac Y Zoning Designation Open Space 20 (1du:20 ac) Pursuant to PSZC 92.21.01 (A,7) Single-family residential uses are permitted. Architectural Review Committee Memo Case #AR-2024-0049 / AMM-2024-0007; 211 Ridge Mountain Drive October 21, 2024 – Page 3 of 7 Development Standards: Pursuant to PSZC Section 92.01.03, the following development standards apply: Standard Required/ Allowed Provided Compliance Min. Setbacks • Front 25 Feet 119 Feet Y • Side (north) 10 Feet 79 Feet Y • Side (south) 10 Feet 93 Feet Y • Rear 15 Feet 22 Feet Y Max. Lot Coverage 10% 8% Y Max. Building Height 18 Feet 27 Feet Y w/apvl of AMM Building Separation 15 Feet 20 Feet Y Perimeter Wall Height None proposed Parking 2 spaces (covered) 2 spaces Y Hillside Review Criteria: PSZC Section 93.13.00(B)(4) requires that architectural review of hillside development shall consider the following criteria: Guidelines [PSZC 93.13.00(B)(4)(a)] Compliance 1. Rock and soil exposure; Y The proposed dwelling is designed with multiple floor levels and steps with the topography of the site. 2. Size of building pad; Y The proposed dwelling is large but is proportionate with the size of the lot. 3. Design considerations, such as supporting stilts, colors and building arrangement; Y The dwelling generally follows the topography of the site in terms of floor levels, however due to the steep topography of the site, retaining walls are proposed that are broken down into multiple walls, each which does not exceed 6 feet in height. 4. Screening of parking areas; Y The parking is in a garage and is screened from public view. 5. Landscaping plans; Y The site is generally left in a natural state with various desert- appropriate trees, shrubs, and groundcovers proposed. Grading will be necessary to establish the multi-level building pad and driveway. 6. Continuity with surrounding development; Y Architectural Review Committee Memo Case #AR-2024-0049 / AMM-2024-0007; 211 Ridge Mountain Drive October 21, 2024 – Page 4 of 7 Guidelines [PSZC 93.13.00(B)(4)(a)] Compliance The proposed dwelling is contemporary in its architecture, consistent with many other homes in the vicinity. 7. Sensitivity to existing view corridors. Y The home is located toward the rear (west side) of the site such that it does not impede views from the public street or adjacent parcels. Architectural Review Criteria and Findings: PSZC Section 94.04.00(E) requires the approval authority to evaluate the application and make findings for conformance to the following criteria: Criteria and Findings [PSZC 94.04.00(E)] Compliance 1. The architectural treatment is consistent on all four sides of the proposed building(s), unless otherwise approved by the ARC; Y The architectural treatment is consistent on all four sides. 2. The design of accessory structures, such as carports, cabanas, and similar accessory structures, shall be consistent with the form, materials and colors of the principal building(s), unless otherwise approved by the ARC; Y The project includes a pair of guest rooms in an attached integrated pavilion. 3. The façade elements and fenestration are composed in a harmonious manner; Y The facades are consistent in detailing and harmonious with one another. 4. The proposed materials are consistent with the context of the site, adjacent buildings, and the desert environment; Y The exterior materials include stucco, painted steel, exposed aggregate concrete, clear anodized aluminum, and a custom concrete block integrated with metal trim in the joints and white marble mosaic. 5. The proposed color scheme is appropriate to the desert environment and consistent with the site context; Y The dwelling is primarily white with light grey accents in the metal column covers. The home is very modern in its architectural aesthetic and as such, the white, while not a color that “blends” with the hillside is appropriate for the style of the home. Architectural Review Committee Memo Case #AR-2024-0049 / AMM-2024-0007; 211 Ridge Mountain Drive October 21, 2024 – Page 5 of 7 Criteria and Findings [PSZC 94.04.00(E)] Compliance 6. Shading devices and sun control elements, excluding landscape materials, are provided to address environmental conditions and solar orientation; Y The proposed dwelling has large expanses of floor to ceiling glazing which is provided with significant cantilevered roof eaves and custom cast concrete architectural screen panels. Early morning sun angles may pose glare problems, but by mid / late morning the extended roof eaves should be effective in protecting the glazing from direct heat gain from the sun. 7. The proposed landscape plan is consistent with the requirements of PSMC Chapter 8.60; Y The project will be conditioned to meet the water -efficiency standards of PSMC 8.60. 8. The proposed landscape plan is consistent with all applicable zoning requirements, including any streetscape requirements, landscape buffer requirements, and screening requirements; Y The landscape plan integrates appropriate drought -tolerant plant and tree species and generally provides for a naturalized landscape setting. 9. The shading for pedestrian facilities on the subject site or abutting public right(s)-of-way is adequate; NA The site takes access from a private street with no sidewalks. There are no street trees in this area and none are proposed. 10. The proposed lighting plan is consistent with the requirements of PSZC Section 93.21.00, and the proposed lighting will not materially impact adjacent properties; Y The project incorporates only low-level landscape lighting highlighting trees and planter beds and in-ground driveway edge lighting. The project will also be conditioned to conform to PSZC 93.21.00. 11. Appropriateness of signage locations and dimensions relative to the building façade(s), or appropriateness of the site location for any freestanding signage, as may be warranted for the development type; NA NA 12. Screening is provided for mechanical equipment and service yards, so as to screen such facilities from view from public rights- of-way and abutting properties; Y Architectural Review Committee Memo Case #AR-2024-0049 / AMM-2024-0007; 211 Ridge Mountain Drive October 21, 2024 – Page 6 of 7 Criteria and Findings [PSZC 94.04.00(E)] Compliance All mechanical screening (roof-mounted photovoltaics or ground mounted) will be conditioned to be screened in compliance with the Zoning Code. Properly ventilated and accessible mechanical equipment rooms strategically located beneath the home tied to underfloor ductwork will be concealed from view. 13. The proposed application is consistent with any adopted design standards of an applicable specific plan, planned development district, or other applicable adopted design standards and regulations. NA The site is not within a specific plan nor are there other adopted design standards that apply in this case. Administrative Minor Modification (“AMM”) criteria: PSZC Section 94.06.01(B,3) requires the approval authority to make all of the following findings based on the evidence presented before approving the AMM. Guidelines [PSZC 93.13.00(B)(4)(a)] Compliance 1. The requested minor modification is consistent with the general plan, applicable specific plan(s) and overall objectives of the zoning ordinance; Y The overall object of the zoning code is the orderly development of the City. The proposed AMM is consistent with the General Plan and Zoning ordinance in that it provides for modest adjustments in development standards based on a consistently applied set of findings and criteria. 2. The neighboring properties will not be adversely affected as a result of the approval or conditional approval of the minor modification; Y The neighboring properties will not be affected because the proposed height of the dwelling will not block views or impact adjacent properties in any way. The over-height condition primarily occurs at the westerly end of the north (side) elevation where the subterranean garage has exposure on one elevation. This area should not be visible from adjacent properties nor the front of the lot facing Ridge Mountain Drive (a private roadway). 3. The approval or conditional approval of the minor modification will not be detrimental to the health, safety, or general welfare of persons residing or working on the site or in the vicinity; Y Architectural Review Committee Memo Case #AR-2024-0049 / AMM-2024-0007; 211 Ridge Mountain Drive October 21, 2024 – Page 7 of 7 Guidelines [PSZC 93.13.00(B)(4)(a)] Compliance The.health, safety and general welfare of persons in the vicinity of the project site will not be adversely impacted because the proposed dwelling must conform to the California Building Code which is intended to protect public health safety and welfare. 4. The approval of the minor modification is justified by environmental features, site conditions, location of existing improvements, or historic development patterns of the property or neighborhood. Y The AMM is justified by the steep topography of the site which necessitates stepping of the building pad . The home conforms in terms of height as measured from adjacent grades. The design proposes tucking the garage under the home, making it less obtrusive to adjoining properties, however in doing so, causes the overall height of the dwelling to be greater than otherwise allowed by the development standards for R-1 development in that location. ENVIRONMENTAL ANALYSIS: The proposed development is considered a “project” pursuant to the California Environmental Quality Act (“CEQA”). Staff has evaluated the application and determined it eligible to be deemed categorically exempt pursuant to Section 15303(a) of the CEQA Guidelines (Class 3 exemption: New Single-Family Residence). CONCLUSION: The proposed dwelling affirmatively meets the findings and criteria necessary for approval of the Major Architectural application and the Administrative Minor Modification application. It is consistent with the guidelines in the City’s hillside ordinance. A draft resolution and conditions are attached for the ARC’s consideration. PREPARED BY: Ken Lyon, RA, Principal City Planner REVIEWED BY: Christopher Hadwin, Director of Planning Services ATTACHMENTS: A. Vicinity Map B. Resolution and Conditions of Approval C. Application materials and Public Integrity Disclosure Form ATTACHMENT #A Department of Planning Services Vicinity Map CITY OF PALM SPRINGS Case AR-2024-0049 / AMM 2024-0007 SFR at 211 Ridge Mountain Road ATTACHMENT #B RESOLUTION NO. ____ A RESOLUTION OF THE ARCHITECTURAL REVIEW COMMITTEE OF THE CITY OF PALM SPRINGS, CALIFORNIA, APPROVING A MAJOR ARCHITECTURAL APPLICATION AND AN ADMINISTRATIVE MINOR MODIFICATION APPLICATION FOR THE DEVELOPMENT OF A 7,900-SQUARE-FOOT SINGLE-FAMILY RESIDENCE ON A 2.34-ACRE HILLSIDE LOT LOCATED AT 211 RIDGE MOUNTAIN DRIVE ZONE: OPEN SPACE-20, GENERAL PLAN: ESTATE RESIDENTIAL, (APN: 513-570-001), CASE AR-2024-0049 & AMM-2024-0007). WHEREAS, Kovac Design Studio, on behalf of Stephen Whyte, (Owner, “Applicant”), filed a Major Architectural Review application and an Administrative Minor Modification application with the City, pursuant to Palm Springs Zoning Code (PSZC) Sections 94.04.00 (“architectural review”), 93.13.00 (“hillside development”), and 94.06.01 (“minor modification”) of the Palm Springs Zoning Code, for construction of a single-family residence at 211 Ridge Mountain Drive; (“the Project”); and WHEREAS, On April 8, 2021, the City Council adopted Ordinance No. 2042, amending Section 94.04.00 of the PSZC to reassign review of Major Architectural Review applications from the City’s Planning Commission to the City’s Architectural Review Committee (“ARC”); and WHEREAS, On June 27, 2024, City staff notified owners of properties immediately adjacent to the project site of receipt of the application pursuant to Zoning Code Section 93.13.00(B,1,b); and WHEREAS, On October 8, 2024, City Staff notified owners of properties immediately adjacent to the project site that the project would be considered by the ARC at a noticed public meeting on October 21, 2024, pursuant to PSZC 93.13.00(B)(1)(c); and WHEREAS, On October 21, 2024, the ARC held a public meeting in accordance with applicable public law. At said meeting, the ARC carefully reviewed and considered all the evidence presented in connection with the Project, including, but not limited to, the staff report, and all written and oral testimony presented. THE ARCHITECTURAL REVIEW COMMITTEE DOES HEREBY RESOLVE AS FOLLOWS: SECTION 1: The proposed single-family residence is considered a project pursuant to the California Environmental Quality Act (CEQA). The Architectural Review Committee has evaluated the Project pursuant to CEQA and determined it to be Categorically Exempt from further analysis under CEQA Guidelines Section 15303(a) (Class 3, One new single-family residence). SECTION 2: As demonstrated in the staff report, the project conforms to the review criteria and Architectural Review Committee Resolution ____ October 21, 2024 Case AR-2024-0049 / AMM-2024-0007 Page 2 of 2 SFR at 211 Ridge Mountain Drive findings of PSZC Sections 93.13.00 (“hillside development”), 94.04.00 (“architectural review”), and 94.06.01 (“minor modifications”), subject to conditions of approval. Based upon the foregoing, the ARC hereby approves Cases AR-2024-0049 and AMM-2024- 0007, for the construction of a 7,900-square foot single-family residence on a hillside lot located at 211 Ridge Mountain Drive (APN: 513-570-001), subject to the conditions of approval attached herein as Exhibit A. ADOPTED this 21st day of October, 2024. AYES: NOES: EXCUSED: ABSENT: ATTEST: CITY OF PALM SPRINGS, CALIFORNIA ______________________________________ Christopher Hadwin Director of Planning Services RESOLUTION NO._______ EXHIBIT A – CONDITIONS OF APPROVAL Case AR-2024-0049 / AMM-2024-0007 Single Family Residence at 211 Ridge Mountain Drive (APN 513-570-001) October 21, 2024 Before final acceptance of the project, all conditions listed below shall be completed to the satisfaction of the City Engineer, the Director of Planning Services, the Director of Building and Safety, the Chief of Police, the Fire Chief or their designee, depending on which department recommended the condition. Any agreements, easements or covenants required to be entered into shall be in a form approved by the City Attorney. ADMINISTRATIVE CONDITIONS ADM 1. Project Description. This approval is for the project described per Case AR- 2024-0049 / AMM-2024-0007; except as modified with the conditions below; ADM 2. Reference Documents. The site shall be developed and maintained in accordance with the approved plans including site plans, architectural elevations, exterior materials and colors, landscaping, and grading on file in the Planning Division except as modified by the conditions below. ADM 3. Conform to all Codes and Regulations. The project shall conform to the conditions contained herein, all applicable regulations of the Palm Springs Zoning Ordinance, Municipal Code, and any other City County, State and Federal Codes, ordinances, resolutions and laws that may apply. ADM 4. Minor Deviations. The Director of Planning or designee may approve minor deviations to the project description and approved plans in accordance with the provisions of the Palm Springs Zoning Code. ADM 5. Indemnification. The owner/applicant shall defend, indemnify, and hold harmless the City of Palm Springs, its elected officials, agents, officers, and employees (“Indemnitees”) from any claim, action, or proceeding against the City of Palm Springs or any Indemnitee(s), arising, in any way, out of the activities authorized by this Land Use Permit. The City will promptly notify the applicant of any such claim, action, or proceeding and the applicant will either undertake defense of the matter and pay the City's associated legal costs or will advance funds to pay for defense of the matter by the City Attorney. If the City fails to promptly notify the applicant of any such claim, action or proceeding or fails to cooperate fully in the defense, the applicant shall not, Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 2 of 13 thereafter, be responsible to defend, indemnify, or hold harmless the Indemnitees. Notwithstanding the foregoing, the City retains the right to settle or abandon the matter without the applicant's consent but should it do so, the City shall waive the indemnification herein, except, the City's decision to settle or abandon a matter following an adverse judgment or failure to appeal, shall not cause a waiver of the indemnification rights herein. ADM 6. Maintenance and Repair. The property owner(s) and successors and assignees in interest shall maintain and repair the improvements including and without limitation all structures, sidewalks, bikeways, parking areas, landscape, irrigation, lighting, walls, and fences that extend onto private property, in a first class condition, free from waste and debris, and in accordance with all applicable law, rules, ordinances and regulations of all federal, state, and local bodies and agencies having jurisdiction at the property owner’s sole expense. This condition shall be included in the recorded covenant agreement for the property if required by the City. ADM 7. Time Limit on Approval. Approval of the Major Architectural Application (MAJ) shall be valid for a period of two (2) years from the effective date of the approval. Extensions of time may be granted by the Planning Commission upon demonstration of good cause. ADM 8. Right to Appeal. Decisions of an administrative officer or agency of the City of Palm Springs may be appealed in accordance with Municipal Code Chapter 2.05.00. Permits will not be issued until the appeal period has concluded. ADM 9. Park Development Fees. The developer shall dedicate land or pay a fee in lieu of a dedication, at the option of the City. The in-lieu fee shall be computed pursuant to Ordinance No. 1632, Section IV, by multiplying the area of park to be dedicated by the fair market value of the land being developed plus the cost to acquire and improve the property plus the fair share contribution, less any credit given by the City, as may be reasonably determined by the City based upon the formula contained in Ordinance No. 1632. In accordance with the Ordinance, the following areas or features shall not be eligible for private park credit: golf courses, yards, court areas, setbacks, development edges, slopes in hillside areas (unless the area includes a public trail) landscaped development entries, meandering streams, land held as open space for wildlife habitat, flood retention facilities and circulation improvements such as bicycle, hiking and equestrian trails (unless such systems are directly linked to the City’s community -wide system and shown on the City’s master plan). Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 3 of 13 ENVIRONMENTAL ASSESSMENT CONDITIONS ENV 1. Notice of Exemption Filing Fee. The project is exempt from further evaluation pursuant to the California Environmental Quality Act (CEQA). The applicant is responsible for payment to the City of the $50 fee for electronic filing of the exemption determination with the County Clerk within two business days of the Commission’s final action on the project. Coordinate this payment with the project planner. ENV 2. California Fish & Game Filing Fee. The project is required to pay a fish and game impact fee as defined in Section 711.4 of the California Fish and Game Code. The applicant is responsible for payment to the City of the CFG impact fee. Coordinate this payment with the project planner. The project may be eligible for exemption or refund of this fee by the California Department of Fish & Game. Applicants may apply for a refund by the CFG at www.dfg.ca.gov for more information. ENV 3. Cultural Resource Survey Required. Prior to any ground disturbing activity, including clearing and grubbing, installation of utilities, and/or any construction related excavation, an Archaeologist qualified according to the Secretary of the Interior’s Standards and Guidelines, shall be employed to survey the area for the presence of cultural resources identifiable on the ground surface. ENV 4. Cultural Resource Site Monitoring. There is a possibility of buried cultural or Native American tribal resources on the site. A Native American Monitor shall be present during all ground-disturbing activities. (check for duplication in engineering conditions) a). A Native American Monitor(s) shall be present during all ground disturbing activities including clearing and grubbing, excavation, burial of utilities, planting of rooted plants, etc. Contact the Agua Caliente Band of Cahuilla Indian Cultural Office for additional information on the use and availability of Cultural Resource Monitors. Should buried cultural deposits be encountered, the Monitor shall contact the Director of Planning. After consultation the Director shall have the authority to halt destructive construction and shall notify a Qualified Archaeologist to further investigate the site. If necessary, the Qualified Archaeologist shall prepare a treatment plan for submission to the State Historic Preservation Officer and Agua Caliente Cultural Resource Coordinator for approval. b). Two copies of any cultural resource documentation generated in connection with this project, including reports of investigations, record search results and site records/updates shall be forwarded to the Tribal Planning, Building, and Engineering Department and one copy to the City Planning Department prior to final inspection. Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 4 of 13 PLANNING DEPARTMENT CONDITIONS PLN 1. Outdoor Lighting Conformance. Exterior lighting plans, including a photometric site plan showing the project’s conformance with Section 93.21.00 Outdoor Lighting Standards of the Palm Springs Zoning ordinance, shall be submitted for approval by the Department of Planning prior to issuance of a building permit. Manufacturer's cut sheets of all exterior lighting on the building and in the landscaping shall be included. If lights are proposed to be mounted on buildings, down-lights shall be utilized. No lighting of hillsides is permitted. PLN 2. Water Efficient Landscaping Conformance . The project is subject to the Water Efficient Landscape Ordinance (Chapter 8.60.00) of the Palm Springs Municipal Code and all other water efficient landscape ordinances. The applicant shall submit a landscape and irrigation plan to the Director of Planning for review and approval prior to the issuance of a building permit. Landscape plans shall be approved by the Riverside County Agricultural Commissioner's Office prior to submittal. Prior to submittal to the City, landscape plans shall also be certified by the local water agency that they are in conformance with the water agency’s and the City’s Water Efficient Landscape Ordinance PSMC 8.60. PLN 3. Flat Roof Requirements. Roof materials on flat roofs (less than 2:12) must conform to California Title 24 thermal standards for “Cool Roofs”. Such roofs must have a minimum initial thermal emittance of 0.75 or a minimum SRI of 64 and a three-year aged solar reflectance of 0.55 or greater. Only matte (non-specular) roofing is allowed in colors such as beige or tan. PLN 4. Maintenance of Awnings & Projections. All awnings shall be maintained and periodically cleaned. PLN 5. Screen Roof-mounted Equipment. All roof mounted mechanical equipment shall be screened per the requirements of Section 93.03.00 of the Zoning Ordinance. PLN 6. Surface Mounted Downspouts Prohibited. No exterior downspouts shall be permitted on any facade on the proposed building(s) that are visible from adjacent streets or residential and commercial areas. PLN 7. Pool Enclosure Approval Required. Details of fencing or walls around pools (material and color) and pool equipment areas shall be submitted for approval by the Planning Department prior to issuance of Building Permits. Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 5 of 13 PLN 8. Exterior Alarms & Audio Systems. No sirens, outside paging or any type of signalization will be permitted, except approved alarm systems. PLN 9. Outside Storage Prohibited. No outside storage of any kind shall be permitted except as approved as a part of the proposed plan. PLN 10. No off-site Parking. Vehicles associated with the operation of the proposed development including company vehicles or employees vehicles shall not be permitted to park off the project site unless a parking management plan has been approved by the Planning Department. PLN 11. Pad Elevations. Final building pad elevations shall not vary more than 12 inches above or below the pad elevation established by the approved preliminary grading plan and / or tentative map. Any deviations from this provision shall require approval by the Architectural Review Committee and/or the Planning Commission. PLN 12. (add any additional conditions imposed by the Architectural Review Committee, here) POLICE DEPARTMENT CONDITIONS POL 1. Developer shall comply with Section II of Chapter 8.04 “Building Security Codes” of the Palm Springs Municipal Code. BUILDING DEPARTMENT CONDITIONS BLD 1. Prior to any construction on-site, all appropriate permits must be secured. ENGINEERING DEPARTMENT CONDITIONS APPLICATION FOR APPROVAL OF A SINGLE- FAMILY RESIDENCE LOCATED AT 211 RIDGE MOUNTAIN DRIVE, (APN 513-570-001), SECTION 34, TOWNSHIP 4 S, RANGE 4 E, S.B.M., CASE NO. AR-2024-0049, ENG. FILE NO. 4863. The Engineering Services Department recommends that if this application is approved, such approval is subject to the following conditions being completed in compliance with City standards and ordinances. Before final acceptance of the project, all conditions listed below shall be completed to the satisfaction of the City Engineer. Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 6 of 13 All Grading Plans, Improvement Plans, Required Studies and Documents listed below, must be submitted to Engineering Services Department for review and approval. STREETS ENG 1. Any improvements within the public right-of-way require a City of Palm Springs Encroachment Permit. All improvements are subject to inspection and a 48-hour inspection notification is required ENG 2. Provide proposed finish floor elevations of all proposed structures, existing structures on site, and all adjacent off-site structures. Provide proposed on-site drainage flow designs. This information is required prior to site plan approval. RIDGE MOUNTAIN DRIVE (PRIVATE) ENG 3. Construct a driveway approach in accordance with City of Palm Springs Standard Drawing No.201 ENG 4. Remove and replace existing asphalt concrete pavement where required, in accordance with applicable City standards. ENG 5. All broken or off grade street improvements along the project frontage shall be repaired or replaced. SANITARY SEWER ENG 6. All sanitary facilities shall be connected to the public sewer system. New laterals shall not be connected at manholes. ENG 7. The project is subject to a sewer assessment fee of $146.19 per lot for construction of the 15" sewer main in Avenida Granada, Calle Palo Fierro and Laverne Way. The fee shall be paid prior to issuance of the building permit. GRADING ENG 8. Submit a Precise Grading Plan prepared by a California licensed civil engineer to the Engineering Services Department for review and approval. The Precise Grading plan shall be approved by the City Engineer prior to grading permit issuance. a. A Fugitive Dust Control Plan shall be prepared by the applicant and/or its grading contractor and submitted to the Engineering Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 7 of 13 Services Department for review and approval. The applicant and/or its grading contractor shall be required to comply with Chapter 8.50 of the City of Palm Springs Municipal Code and shall be required to utilize one or more “Coachella Valley Best Available Control Measures” as identified in the Coachella Valley Fugitive Dust Control Handbook for each fugitive dust source such that the applicable performance standards are met. The applicant’s or its contractor’s Fugitive Dust Control Plan shall be prepared by staff that has completed the South Coast Air Quality Management District (AQMD) Coachella Valley Fugitive Dust Control Class. The applicant and/or its grading contractor shall provide the Engineering Services Department with current and valid Certificate(s) of Completion from AQMD for staff that have completed the required training. For information on attending a Fugitive Dust Control Class and information on the Coachella Valley Fugitive Dust Control Handbook and related “PM10” Dust Control issues, please contact AQMD at (866) 861-3878, or at http://www.AQMD.gov. A Fugitive Dust Control Plan, in conformance with the Coachella Valley Fugitive Dust Control Handbook, shall be submitted to and approved by the Engineering Services Department prior to approval of the Grading plan. b. The first submittal of the Grading Plan shall include the following information: a copy of final approved conformed copy of Conditions of Approval; a copy of a final approved conformed copy of the Site Plan; a copy of current Title Report; a copy of Soils Rep ort; and a copy of the associated Hydrology Study/Report. ENG 9. Prior to approval of a Grading Plan (or issuance of a Grading Permit), the applicant shall obtain written approval to proceed with construction from the Agua Caliente Band of Cahuilla Indians, Tribal Historic Preservation Officer or Tribal Archaeologist (a copy of the written approval must be provided to the City) . The applicant shall contact the Tribal Historic Preservation Officer or the Tribal Archaeologist at ACBCI-THPO@aguacaliente.net to determine their requirements, if any, associated with grading or other construction. The applicant is advised to contact the Tribal Historic Preservation Officer or Tribal Archaeologist as early as possible. If required, it is the responsibility of the applicant to coordinate scheduling of Tribal monitors during grading or other construction, and to arrange payment of any required fees associated with Tribal monitoring. ENG 10. This project is located within a desert tortoise habitat area. In accordance with the United States Fish & Wildlife Service (USFWS) Permit and the Coachella Valley Multiple Species Habitat Conservation Plan (CVMSHCP) Permit Condition No. 45, the City shall notify the Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 8 of 13 USFWS 45 days prior to issuance of Grading Permit to allow for the potential salvage of adult tortoises (by USFWS) within the 45-day notification period. For more information, contact the Coachella Valley Association of Governments at (760) 346 -1127 or go the following website: http://www.cvmshcp.org/Final%20USFWS%20Permit.htm. A copy of the results of the desert tortoise clearance survey shall be provided to the City prior to issuance of grading permit. ENG 11. In accordance with an approved PM-10 Dust Control Plan, temporary dust control perimeter fencing shall be installed. Fencing shall have screening that is tan in color; green screening will not be allowed. Temporary dust control perimeter fencing shall be installed after issuance of Grading Permit, and immediately prior to commencement of grading operations. ENG 12. Temporary dust control perimeter fence screening shall be appropriately maintained, as required by the City Engineer. Cuts (vents) made into the perimeter fence screening shall not be allowed. Perimeter fencing shall be adequately anchored into the ground to resist wind loading. ENG 13. Within 10 days of ceasing all construction activity and when construction activities are not scheduled to occur for at least 30 days, the disturbed areas on-site shall be permanently stabilized, in accordance with Palm Springs Municipal Code Section 8.50.022. Following stabilization of all disturbed areas, perimeter fencing shall be removed, as required by the City Engineer. ENG 14. Prior to issuance of grading permit, the applicant shall provide verification to the City that the Tribal Habitat Conservation Plan (THCP) fee has been paid to the Agua Caliente Band of Cahuilla Indians in accordance with the THCP. ENG 15. Drainage swales shall be provided adjacent to all curbs and sidewalks to keep nuisance water from entering the public streets, roadways, or gutters. ENG 16. A Notice of Intent (NOI) to comply with the California General Construction Stormwater Permit (Water Quality Order 2022 -0057- DWQ as adopted September 8, 2022) is required for the proposed development via the California Regional Water Quality Control Board online SMARTS system. A copy of the executed letter issuing a Waste Discharge Identification (WDID) number shall be provided to the City Engineer prior to issuance of a grading or building permit. Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 9 of 13 ENG 17. This project requires preparation and implementation of a stormwater pollution prevention plan (SWPPP). As of September 4, 2012, all SWPPPs shall include a post-construction management plan (including Best Management Practices) in accordance with the current Construction General Permit. Where applicable, the approved final project-specific Water Quality Management Plan shall be incorporated by reference or attached to the SWPPP as the Post -Construction Management Plan. A copy of the up -to-date SWPPP shall be kept at the project site and be available for review upon request. ENG 18. In accordance with City of Palm Springs Municipal Code, Section 8.50.022 (h), the applicant shall post with the City a cash bond of eight hundred dollars ($800) (if there is disturbance of 5,000 square feet or more) at the time of issuance of grading permit for mitigation measures for erosion/blowsand relating to this property and development. ENG 19. A Geotechnical/Soils Report prepared by a California registered Geotechnical Engineer shall be required for and incorporated as an integral part of the grading plan for the proposed development. A copy of the Geotechnical/Soils Report shall be submitted to the Engineering Services Department with the first submittal of a grading plan. (if required) ENG 20. The applicant shall provide all necessary geotechnical/soils inspections and testing in accordance with the Geotechnical/Soils Report prepared for the project. All backfill, compaction, and other earthwork shown on the approved grading plan shall be certified by a California registered geotechnical or civil engineer, certifying that all grading was performed in accordance with the Geotechnical/Soils Report prepared for the project. Documentation of all compaction and other soils testing are to be provided even though there may not be a grading plan for the project. Prior to issuance of Building Permits. ENG 21. The applicant shall provide Grading Certification for all building (or structure) pads in conformance with the approved grading plan to the Engineering Services Department for review and approval prior to issuance of Building Permits. ENG 22. In cooperation with the California Agricultural Commissioner and the California Department of Food and Agriculture Red Imported Fire Ant Project, applicants for grading permits involving a grading plan and involving the export of soil will be required to present a clearance document from a Department of Food and Agriculture representative in the form of an approved “Notification of Intent To Move Soil From or Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 10 of 13 Within Quarantined Areas of Orange, Riverside, and Los Angeles Counties” (Revised - RIFA Form CA-1) prior to approval of the Grading Plan (if required). The California Department of Food and Agriculture office is located at 6819 East Gage Avenue, Commerce, Ca 90040 (Phone (760) 782-3271, (562) 505-6415), Sonia.Oran@cdfa.ca.gov DRAINAGE ENG 23. All stormwater runoff across the property shall be accepted and conveyed in a manner acceptable to the City Engineer and released to an approved drainage system. Stormwater runoff may not be released directly to the adjacent streets without first intercepting and treating with approved Best Management Practices (BMPs). ENG 24. All stormwater runoff passing through the site shall be accepted and conveyed across the property in a manner acceptable to the City Engineer. For all stormwater runoff falling on the site, on -site retention or other facilities approved by the City Engineer shall be required to contain the increased stormwater runoff generated by the development of the property. Provide a hydrology study to determine the volume of increased stormwater runoff due to development of the site, and to determine required stormwater runoff mitigation measures for the proposed development. Final retention basin sizing and other stormwater runoff mitigation measures shall be determined upon review and approval of the hydrology study by the City Engineer and may require redesign or changes to site configuration or layout consistent with the findings of the final hydrology study. No more than 40-50% of the street frontage parkway/setback areas should be designed as retention basins. On-site open space, in conjunction with dry wells and other subsurface solutions should be considered as alternatives to using landscaped parkways for on-site retention. ENG 25. The project is subject to flood control and drainage implementation fees. The acreage drainage fee at the present time is $8,651.15 per acre in accordance with Resolution No. 15189. Fees shall be paid prior to issuance of a building permit. GENERAL ENG 26. Any utility trenches or other excavations within existing asphalt concrete pavement of off-site streets required by the proposed development shall be backfilled and repaired in accordance with City of Palm Springs Standard Drawing No. 115. Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 11 of 13 ENG 27. All proposed utility lines shall be installed underground. ENG 28. All existing utilities shall be shown on the improvement plans if required for the project. The existing and proposed service laterals shall be shown from the main line to the property line. ENG 29. Upon approval of any improvement plan (if required) by the City Engineer, the improvement plan shall be provided to the City in digital format, consisting of a DWG (AutoCAD drawing filetype) and PDF (Adobe Acrobat document filetype) formats. Variation of the type and format of the digital data to be submitted to the City may be authorized, upon prior approval by the City Engineer. ENG 30. The original improvement plans prepared for the proposed development and approved by the City Engineer (if required) shall be documented with record drawing “as-built” information and returned to the Engineering Services Department prior to issuance of a final certificate of occupancy. Any modifications or changes to approved improvement plans shall be submitted to the City Engineer for approval prior to construction. ENG 31. Nothing shall be constructed or planted in the corner cut -off area of any intersection or driveway which does or will exceed the height required to maintain an appropriate sight distance per City of Palm Springs Zoning Code Section 93.02.00, D. ENG 32. All proposed trees within the public right-of-way and within 10 feet of the public sidewalk and/or curb shall have City approved deep root barriers installed in accordance with City of Palm Springs Standard Drawing No. 904. TRAFFIC ENG 33. All damaged, destroyed, or modified pavement legends, traffic control devices, signing, striping, and streetlights, associated with the proposed development shall be replaced as required by the City Engineer prior to issuance of a Certificate of Occupancy. ENG 34. Construction signing, lighting and barricading shall be provided during all phases of construction as required by City Standards or as directed by the City Engineer. As a minimum, all construction signing, lighting and barricading shall be in accordance with Part 6 “Temporary Traffic Control” of the California Manual on Uniform Traffic Control Devices (CAMUTCD), dated November 7, 2014, or subsequent editions in force at the time of construction. Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 12 of 13 ENG 35. This property is subject to the Transportation Uniform Mitigation Fee which shall be paid prior to issuance of building permit. FIRE DEPARTMENT CONDITIONS FID 1. These Fire Department conditions may not provide all requirements. Owner/developer is responsible for all applicable state and locally adopted fire codes. Detailed plans are still required for review. Conditions are subject to final plan check and review. FID 2. Fire Department Conditions were based on the 2022 California Fire Code as adopted by City of Palm Springs, Palm Springs Municipal Code, PSFD Appendix “T” Development Requirements. This building will require fire sprinklers. FID 3. Conditions of Approval – “Conditions of Approval” received from the Palm Springs Planning Department must be submitted with each plan set. Failure to submit will result in a delay of plan approval. FID 4. Plans and Permits: Permits and Electronic scaled drawings are required for this project. Plan reviews can take up to 20 working days. A deposit for Plan Check and Inspection Fees is required at the time of Plan Submittal. These fees are established by Resolution of the Palm Springs City Council. Complete listings and manufacturer’s technical data sheets for all system materials shall be included with plan submittals. All system materials shall be UL listed or FM approved for fire protection service and approved by the Fire Prevention Bureau prior to installation. Plans shall include all necessary engineering features, including all hydraulic reference nodes, pipe lengths and pipe diameters as required by the appropriate codes and standards. Plans and supporting data, (calculations and manufacturers technical data sheets) including fire flow data, shall be submitted with each plan submittal. Complete and accurate legends for all symbols and abbreviations shall be provided on the plans. FID 5. Access During/After Construction: Access for firefighting equipment shall be provided to the immediate job site at the start of construction and maintained until all construction is complete. Fire apparatus access roads Conditions of Approval - Case #AR-2024-0049 / AMM-2024-0007 211 Ridge Mountain Drive October 21, 2024 Page 13 of 13 shall have an unobstructed width of not less than 24 feet and an unobstructed vertical clearance of not less than 13'-6". Fire Department access roads shall have an all-weather driving surface and support a minimum weight of 73,000 lbs. FID 6. Chapter 7A: Since the proposed residence is in our city’s very high fire area, architect must design structure 7A. FID 7. Private Fire Hydrants: Additional private hydrants may be required. FID 8. NFPA 13D Fire Sprinklers Required: An automatic fire sprinkler system is required. Only a C-16 licensed fire sprinkler contractor shall perform system design and installation. System to be designed and installed in accordance with NFPA standard 13D, 2022 Editions, as modified by local ordinance. FID 9. Residential Smoke Alarms Required: Shall be interconnected so that operation of any smoke alarm or fire sprinkler flow switch causes all smoke alarms within the dwelling & guest house to sound and activate the exterior horn/strobe END OF CONDITIONS ATTACHMENT #C 7 June 2024 Project Private Residence located at: 211 Ridge Mountain Drive Palm Springs, CA 92264 APN: 513-570-001 To: City of Palm Springs Architectural Review Committee Please find enclosed documents and drawings as required for a Major Architectural Review for a new single-family residence on an undeveloped site at 211 Ridge Mountain Drive. Project Overview Located on Lot 1 of the original Ridge Mountain subdivision map, the property represents a challenging development site. The original planning of the subdivision included recommended areas for building envelopes. These areas correspond to the natural grade of the hillside lots to establish the most desirable and logical development sites. Although steep and punctuated by rock outcroppings, Lot 1 does have a natural building shelf where the site flattens relative to the surrounding grades which continue to both rise and fall at once. Lot 1 is 101,930SF (or 2.34 acres) and to reach the designated building shelf an access drive must be designed and engineered. As illustrated on the architectural site plan and civil grading plan included within this submittal, the access drive has been designed to gently traverse the site to achieve elevation without introducing an excessively steep climb. It is intended that the drive will always be incorporated into the landscape utilizing naturally occurring rock outcroppings and native plantings for screening at any point where retaining is required. By utilizing series of stepped walls in the steeper, more challenging locations, none of the driveway retaining walls exceeds 6’-0” in height at any point. Furthermore, the residence responds to the existing and natural terrain of the site stepping with the change in grades resulting in a series of pavilions rather than one large mass. The overarching intent of the residence is to achieve a lightness of form and structure that appears to rest gently on the site. Design As described above, the residence has been conceived of as a series of single-story pavilions that follow the natural grade changes represented by the site. There are seven pavilions ranging in size from just under 800 SF to just under 2,500 SF with a total area of 8,650 gross SF. The lot coverage is less than 7% Page 2 of 2 of the total site area. The roof planes of the pavilions also step with the site overlapping at times to create a rhythm that is suggestive of the topography of the site. All the pavilions are contained within a buildable area that is well within the required setbacks for hillside development, as follows: approximately 119’ from the curb line or east-facing front yard setback, 78’ from the north, side-yard setback, 22’ from the west, rear-yard setback, and 93’ from the south, side-yard setback. The heights of the pavilions range from approximately 14’ to 26’ as they follow the topography of the site and only one of the pavilions has two levels. At 26’ the two-level pavilion is not a traditional two-story structure. Rather it takes advantage of a natural opportunity presented by the topography of the site which is lower at this point to create a tuck-under garage. Furthermore, this pavilion is located beyond another one-story volume which creates a sculptural effect with one volume in front of the other. Because the structure exceeds the 18’ by-right height limit, there is a parallel Administrative Minor Modification application for a taller structure for which we request approval. The maximum height limit allowed by planning code is 30’ and the building does not exceed this at any point. Team This is an extremely challenging site and we recognize the City of Palm Springs as a key member of the team. It is the only way we can achieve success with this development. Further, we come together as design, engineering, and construction professionals; experts in the field who are international, capable, qualified, and experienced. We are excited to be at this point with this project, and respectfully seek your approval and guidance through the process. Respectfully submitted, David Garnett Project Architect | KOVAC A0.0 Cover RIDGE MOUNTAIN 211 RIDGE MOUNTAIN DR, PALM SPRINGS CA 92264 Plot Date: 10/9/2024 Login Name: Dg File Name: PS A0.0 Cover211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 Architectural A0.0 Cover A0.1a View from Ridge Mountain Dr A0.1b View from Northeast A0.1c View from Southeast A0.1d View from Southwest A0.1e View East over Pool A0.1f View of Entry Stairs A0.1g Birdseye View from North A0.1h View from Palms Canyon Dr SURVEY A1.0 Site Photos A1.1 Site Plan A2.1 Garage Level Floor Plan A2.2 Main Level Floor Plan A2.3 Roof Plan A3.1 Exterior Elevations A3.2 Exterior Elevations A4.1 Building Sections Block Screen Detail Material Board Civil C1 Grading Plan C2 Grading Sections Landscape LC-1 Hardscape Plan LP-1 Planting Plan LP-2 Planting Schedule LI-1 Irrigation Plan LI-2 Irrigation Details LL-1 Landscape Lighting Project Description New 2-story single family residence with attached garage, guest rooms and caretaker's unit. Project also includes pool, spa, hardscape and landscape, including driveway and retaining walls. Project Address 211 Ridge Mountain Drive Palm Springs, CA 92264 Assessor Parcel Number 513-570-001 Lot/Parcel Area 101,930 SF (2.340 acres) Tract TR 16495 Map Reference MB 208/050 Block None Lot 1 Arb (Lot Cut Reference)None Zoning O-20 Hillside Development, subject to R-1-A standards (Estate Residential) Hillside Area Yes Very High Fire Hazard Severity Zone (VHFHSZ) Yes Construction Type V-B Fire Sprinklers Yes Occupancy R3 / U Front Yard Setback 25'-0" (120'-6" proposed) Rear Yard Setback 15'-0" (18'-7" proposed) Side Yard Setback 10'-0" (96'-5" and 77'-3" proposed) Max Allowable Height 18'-0" max. allowed by right (max. 12'-0" at setback) 30'-0" max. per 94.06.01(A)(10) pending Administrative Minor Modification approval Proposed Height 27'-1" Stories 2 Parking Required: 2 covered spaces (10x20) Proposed: 2 covered spaces (10x20) Gross Building Area (SF)Main House / Guest Rooms: 7378 Caretaker's Unit: 344 Garage / Storage: 928 Total: 8650 Lot Coverage Building Footprint: 6942 SF Lot Coverage 6942 / 101,930 = 6.81% Sheet List Project Information A0.1a Rendering View from Ridge Mountain DrivePlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1b Rendering View from NortheastPlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1c Rendering View from SoutheastPlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1d Rendering View from SouthwestPlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1e Rendering View East over Pool TerracePlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1f Rendering View at Entry StairsPlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1g Rendering Birdseye View from NorthPlot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 A0.1h Rendering Plot Date: 10/9/2024 Login Name: Dg File Name: PS A0.1x Renderings211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 View from Palms Canyon Drive (House in background) 663 6626616606 5 9 6 58 6586 5 7 657656656 655655 6 5 4 654 6 5 3 653 6 5 2 652651 651650 650649 6496 4 9 6486486 4 8 647647647646646646645645645644644644 643642STRUCTUREBRASS DISC IN T.C. LOCATEDAT THE ESE CURB RETURN ATBOGERT TR. & S PALM CANYON DR.PREPARED SEPTEMBER 16, 2021IN THE CITY OF PALM SPRINGS, COUNTY OF RIVERSIDE, STATE OF CALIFORNIASTEVEN J. VANSTEVEN J. VAN, PLS 6500REG.EXP. 6/30/21REGISTRATIONEXPIRES6-30-21CAIOFLAI NR LRUSDVROYEANRP TSOEFTAANOI S LOF S E JOB NUMBER: BOUNDSSTRUCTUREBOUNDSSTRUCTUREBOUNDS A1.0 Site Photos Plot Date: 10/9/2024 Login Name: Dg File Name: PS A1.0 Photos211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain Lot 1 approx. boundary ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 6 6 3 6626616606596 5 8 6586 5 7 657656656 655655 654654 6 5 3 653652 652651 651650 6 5 0649 6496496486486486476476476466466466456456456446446 4 4 643642SCAR AREAREVISED HEREON+684 +685 +685 +691 +694 +692.5 +688 +691 +689 +689 +685 +694 +692.5 +688 +688 +686.5 +689.5 +685 +692.5 +693 +694.0 +696.0 +700.0 +698.0 +694 +694 +685 +689 +689.5 +684 +696.5 +678.8 +694.5 17'-2" 15'-6" 26'-0"32'-10"35'-4"21'-0"19'-0" 30'-7" 28'-8"27'-4"21'-3"13'-4"48'-0"8'-0"14'-4" 12'-4" 12'-4"16'-4"20'-10" 15'-6" 14'-4" 14'-4" 19'-0" 13'-0" 9'-0"11'-9"4'-0" 4'-0"4'-0"4'-0"10'-8"15'-1"8'-0"4'-0"5'-0"6'-10" 17'-0"18'-0"8'-0"7'-4"9'-4"24'-11"13'-4"3'-0"15'-4"11'-8"Main Entrance Guest Entrance Garbage R o o m Dining R o o m Shower Foyer Kitchen Garden FitnessStudio Main Bed r o o m Bathroom Media Office / L i b r a r y Jacuzzi Terrace Patio Lounge / Living R o o m Water Closet 492 SQ. F T . 209.6 SQ . F T . 91.4 SQ. F T . 233.5 SQ . F T . 462.3 SQ . F T . 349.2 SQ . F T . 300.8 SQ . F T . 401.1 SQ . F T . 510.6 SQ . F T . 771.4 SQ . F T . 205.7 SQ . F T . 135.5 SQ . F T . 45.71 m2 19.47 m2 8.49 m2 21.69 m2 42.95 m2 32.44 m2 27.94 m2 37.27 m2 47.44 m2 19.11 m2 12.58 m2 64.9 SQ . F T . 6.03 m2 Dressing Powder Room Sculpture 343.1 SQ . F T . 31.87 m2 Guest Room 71.67 m2 Pool Terrace Swimmin g Pool Pond Electricit y Room 32.2 SQ . F T . 3.00 m2 247.3 SQ . F T . 22.97 m2 222.1 SQ . F T . 20.63 m2 731.5 SQ . F T . 67.96 m2 386.2 SQ . F T . 35.88 m2 Laundry Terrace Terrace Living Ar e a C o r r i d o r West Win g C o r r i d o r Toilet 1125.1 S Q . F T . 104.52 m2 796.5 SQ . F T . 74.00 m2 433.9 SQ . F T . 40.31 m2 Terrace G u e s t 95.3 SQ . F T . 8.86 m2 259.1 SQ . F T . 24.08 m2 1919.0 S Q . F T . 178.28 m2 Terrace 324.1 SQ . F T . 30.11 m2 Terrace Brasero 306.0 SQ . F T . 28.43 m2 brasero brasero 343.1 SQ . F T . 31.87 m2 Guest Room +680+682+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+ 6 7 1 +683+680 +675 +674 +6 7 3 + 6 7 2 +670+669+668+667+666+665+6 6 0 +655 +650+640+639+638+637+636 +682+657 +676 +677 +678 +679+681+64515'-0'' Rear Yard Setback 10'-0'' Side Yard Setback 10'-0 ' ' Side Yard Setb a c k 25'-0'' FrontYard SetbackWater Fe a t u r e22'-4"93'-5" original buildable area new curb cut and driveway new driveway gate Ridg e M o u nt ai n Dr. prop ert y li n eproperty lineproperty lineproposed fire dept standpipe roof outline above 1 1 9 ' - 4 " 78'- 6 "12'-0"retaining walls per civil retaining walls per civil transformer pad w/ retaining walls per civil retaining walls per civil driveway per civil Enclosed retaining walls per civil Plot Date: 10/9/2024 Login Name: Rs File Name: PS A1.1 Site Plan211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain 0 A1.1 Site Plan 20'01Site Plan 1" = 20' ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 +680+682+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+671+683+680 +675 +6 7 4 + 6 7 3 +672+667+666+665+682+676 +677 +678 +679+681+684 +685 +685 +688 +686.5 Main Entrance Guest Entrance Swimming Pool Pond 423.8 SQ. FT. 39.37 m2 Terrace Guest +684 +685+685 Guest Room 341.3 SQ. FT.341.3 SQ. FT. 31.71 m2 31.71 m2 Guest Room Bike Storage Mechanical GarageCaretaker 324.1 SQ. FT. 310.8 SQ. FT.434.4 SQ. FT. 30.11 m2 28.88 m2 40.36 m2 213.9 SQ. FT. 19.87 m2 Mechanical / pool equipment 459.2 SQ. FT. 42.66 m2 Garbage Room 51.3 SQ. FT. 4.77 m2 Crawlspace HVAC Ducting Underground HVAC ducting to Guest HVAC Ducting +685 +684 +678.8 +680+682+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+671+683+680 +675 +6 7 4 + 6 7 3 +672+667+666+665+682+676 +677 +678 +679+681+684 +685 +685 +688 +686.5 Main Entrance Guest Entrance Swimming Pool Pond 423.8 SQ. FT. 39.37 m2 Terrace Guest +684 +685+685 Guest Room 341.3 SQ. FT.341.3 SQ. FT. 31.71 m2 31.71 m2 Guest Room Bike Storage Mechanical GarageCaretaker 324.1 SQ. FT. 310.8 SQ. FT.434.4 SQ. FT. 30.11 m2 28.88 m2 40.36 m2 213.9 SQ. FT. 19.87 m2 Mechanical / pool equipment 459.2 SQ. FT. 42.66 m2 Garbage Room 51.3 SQ. FT. 4.77 m2 Crawlspace HVAC Ducting Underground HVAC ducting to Guest HVAC Ducting +685 +684 +678.8 +680+682+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+671+683+680 +675 +6 7 4 + 6 7 3 +672+667+666+665+682+676 +677 +678 +679+681+684 +685 +685 +688 +686.5 Main Entrance Guest Entrance Swimming Pool Pond 423.8 SQ. FT. 39.37 m2 Terrace Guest +684 +685+685 Guest Room 341.3 SQ. FT.341.3 SQ. FT. 31.71 m2 31.71 m2 Guest Room Bike Storage Mechanical GarageCaretaker 324.1 SQ. FT. 310.8 SQ. FT.434.4 SQ. FT. 30.11 m2 28.88 m2 40.36 m2 213.9 SQ. FT. 19.87 m2 Mechanical / pool equipment 459.2 SQ. FT. 42.66 m2 Garbage Room 51.3 SQ. FT. 4.77 m2 Crawlspace HVAC Ducting Underground HVAC ducting to Guest HVAC Ducting +685 +684 +678.8 02 A4.1 02 A4.1 02 A3.1 01 A3.1 36'-4"35'-0"01 A3.2 water feature driveway14'-4" in [4.37 m] 7'-8" in [2.34 m] 3'-0" in [0.91 m] 3'-0" in [0.91 m] 3'-0" in [0.91 m]5'-2" in [1.58 m]16'-0" in [4.88 m]0 A2.1 Garage Level Plan 8'Plot Date: 10/9/2024 Login Name: Rs File Name: PS A2.1 Floor Plan211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain 01Garage Level Plan 1/8" = 1'-0" ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 +684 +685 +685+691 +694 +692.5 +688 +691 +689 +689 +685 +694+692.5 +688 +688 +686.5+689.5 +685 +692.5 +693 +694.0 +696.0 +700.0 +698.0 +694 +694 +685 +689 +689.5 +684 +696.5 +678.8 +694.5 Main Entrance Guest Entrance Garbage Room Dining Room Shower Foyer Kitchen Garden Fitness Studio Main Bedroom Bathroom Media Office / Library Jacuzzi Terrace Patio Lounge / Living Room Water Closet 492 SQ. FT. 209.6 SQ. FT. 91.4 SQ. FT.233.5 SQ. FT. 462.3 SQ. FT. 349.2 SQ. FT. 300.8 SQ. FT. 401.1 SQ. FT. 510.6 SQ. FT. 771.4 SQ. FT. 205.7 SQ. FT.135.5 SQ. FT. 45.71 m2 19.47 m2 8.49 m2 21.69 m2 42.95 m2 32.44 m2 27.94 m2 37.27 m2 47.44 m2 19.11 m2 12.58 m2 64.9 SQ. FT. 6.03 m2 Dressing Powder Room Sculpture 343.1 SQ. FT. 31.87 m2 Guest Room 71.67 m2 Pool Terrace Swimming Pool Pond Electricity Room 32.2 SQ. FT. 3.00 m2 247.3 SQ. FT. 22.97 m2 222.1 SQ. FT. 20.63 m2 731.5 SQ. FT. 67.96 m2 386.2 SQ. FT. 35.88 m2 Laundry Terrace Terrace Living Area Corridor West Wing Corridor Toilet 1125.1 SQ. FT. 104.52 m2 796.5 SQ. FT. 74.00 m2 433.9 SQ. FT. 40.31 m2 Terrace Guest 95.3 SQ. FT. 8.86 m2 259.1 SQ. FT. 24.08 m2 1919.0 SQ. FT. 178.28 m2 Terrace 324.1 SQ. FT. 30.11 m2 Terrace Brasero 306.0 SQ. FT. 28.43 m2 brasero brasero 343.1 SQ. FT. 31.87 m2 Guest Room +680+682+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+671+683+680 +675 +6 7 4 +673+672+670+667+666+665+ 6 6 0 +682+676 +677 +678 +679+681+684 +685 +685+691 +694 +692.5 +688 +691 +689 +689 +685 +694+692.5 +688 +688 +686.5+689.5 +685 +692.5 +693 +694.0 +696.0 +700.0 +698.0 +694 +694 +685 +689 +689.5 +684 +696.5 +678.8 +694.5 Main Entrance Guest Entrance Garbage Room Dining Room Shower Foyer Kitchen Garden Fitness Studio Main Bedroom Bathroom Media Office / Library Jacuzzi Terrace Patio Lounge / Living Room Water Closet 492 SQ. FT. 209.6 SQ. FT. 91.4 SQ. FT.233.5 SQ. FT. 462.3 SQ. FT. 349.2 SQ. FT. 300.8 SQ. FT. 401.1 SQ. FT. 510.6 SQ. FT. 771.4 SQ. FT. 205.7 SQ. FT.135.5 SQ. FT. 45.71 m2 19.47 m2 8.49 m2 21.69 m2 42.95 m2 32.44 m2 27.94 m2 37.27 m2 47.44 m2 19.11 m2 12.58 m2 64.9 SQ. FT. 6.03 m2 Dressing Powder Room Sculpture 343.1 SQ. FT. 31.87 m2 Guest Room 71.67 m2 Pool Terrace Swimming Pool Pond Electricity Room 32.2 SQ. FT. 3.00 m2 247.3 SQ. FT. 22.97 m2 222.1 SQ. FT. 20.63 m2 731.5 SQ. FT. 67.96 m2 386.2 SQ. FT. 35.88 m2 Laundry Terrace Terrace Living Area Corridor West Wing Corridor Toilet 1125.1 SQ. FT. 104.52 m2 796.5 SQ. FT. 74.00 m2 433.9 SQ. FT. 40.31 m2 Terrace Guest 95.3 SQ. FT. 8.86 m2 259.1 SQ. FT. 24.08 m2 1919.0 SQ. FT. 178.28 m2 Terrace 324.1 SQ. FT. 30.11 m2 Terrace Brasero 306.0 SQ. FT. 28.43 m2 brasero brasero 343.1 SQ. FT. 31.87 m2 Guest Room +680+682+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+671+683+680 +675 +6 7 4 +673+672+670+667+666+665+ 6 6 0 +682+676 +677 +678 +679+681132'-6"90'-9"38'-0"21'-0"01 A4.1 02 A4.1 02 A4.1 01 A4.1 02 A3.1 01 A3.1 02 A3.2 01 A3.2 157'-6" roof overhang above roof overhang above garage below (see A2.1) roof overhang above water feature Enclosed roof overhang above not for cooking not for cooking driveway 193 in [4.90 m]294 in [7.47 m]28 in [0.71 m] 46 in [1.17 m] 491 2 in [1.25 m] 1101 2 in [2.80 m] 48 in [1.22 m]48 in [1.22 m]48 in [1.22 m]48 in [1.22 m]3161 2 in [8.04 m]168 in [4.27 m]31 in [0.78 m]491 2 in [1.25 m]203 in [5.16 m]3161 2 in [8.04 m]120 in [3.05 m]148 in [3.76 m]24 in [0.61 m]104 in [2.64 m]116 in [2.95 m] 1781 2 in [4.54 m]53 in [1.35 m]43 in [1.10 m]631 2 in [1.61 m] 73 in [1.86 m]6612 in [1.70 m]190 in [4.83 m]168 in [4.27 m]168 in [4.27 m]246 in [6.25 m]84 in [2.13 m]172 in [4.37 m]174 in [4.42 m]25912 in [6.59 m]53 in [1.35 m]84 in [2.13 m]84 in [2.13 m]48 in [1.22 m]48 in [1.22 m] 1211 2 in [3.09 m] 336 in [8.53 m] 116 in [2.95 m] 831 2 in [2.12 m]76 in [1.93 m] 75 in [1.91 m]75 in [1.90 m] 71 in [1.80 m]72 in [1.83 m]48 in [1.22 m]39 in[0.99 m]74 in [1.88 m] 42 in [1.07 m] 1021 2 in [2.61 m]44 in [1.12 m]168 in [4.27 m]40 in [1.02 m] 118 in [3.00 m]74 in [1.88 m]62 in [1.57 m]36 in [0.91 m]4112 in [1.05 m]39 in [0.99 m]36 in [0.91 m]144 in [3.66 m]116 in [2.95 m] 601 2 in [1.53 m]39 in [0.99 m]53 in [1.35 m]36 in [0.91 m]561 2 in [1.43 m] 54 in [1.37 m]47 in [1.20 m]129 in [3.28 m]234 in [5.95 m]105 in [2.67 m]210 in [5.33 m] 391 2 in [1.00 m] 50 in [1.27 m] 391 2 in [1.00 m]39 in[0.99 m]66 in [1.68 m]16812 in [4.28 m]216 in [5.49 m]396 in [10.06 m]288 in [7.31 m] 48 in [1.22 m]30 in [0.76 m] 79 in [2.01 m] 16'-6" in [5.03 m]15'-6" in [4.72 m] 26'-0" in [7.92 m]32'-6" in [9.91 m]35'-0" in [10.67 m]21'-0" in [6.40 m]19'-0" in [5.79 m] 30'-7" in [9.32 m] 28'-8" in [8.74 m]27'-9" in [8.46 m]21'-3" in [6.48 m]13'-8" in [4.17 m]47'-0" in [14.33 m]8'-0" in [2.44 m]14'-4" in [4.37 m] 12'-4" in [3.76 m]15'-4" in [4.67 m]12'-4" in [3.76 m]15'-10" in [4.83 m]21'-6" in [6.55 m]15'-6" in [4.72 m]14'-4" in [4.37 m] 15'-4" in [4.67 m] 19'-0" in [5.79 m] 13'-0" in [3.96 m] 9'-0" in [2.74 m]11'-9" in [3.58 m]4'-0" in [1.22 m]4'-0" in [1.22 m]4'-0" in [1.22 m]4'-0" in [1.22 m]10'-9" in [3.27 m]15'-1" in [4.59 m]8'-0" in [2.44 m]4'-0" in [1.22 m]5'-0" in [1.52 m]6'-10" in [2.08 m] 17'-0" in [5.18 m]18'-0" in [5.49 m]8'-0" in [2.44 m]7'-3" in [2.21 m]9'-4" in [2.84 m]25'-0" in [7.62 m]13'-4" in [4.07 m]planter retaining walls 0 A2.2 Floor Plan 8'Plot Date: 10/9/2024 Login Name: Rs File Name: PS A2.1 Floor Plan211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 01Floor Plan 1/8" = 1'-0" spa maintenance access pool maintenance access +684 +685 +685+691 +694 +692.5 +688 +691 +689 +689 +685 +694+692.5 +688 +688 +686.5+689.5 +685 +692.5 +693 +694.0 +696.0 +700.0 +698.0 +694 +694 +685 +689 +689.5 +684 +696.5 +678.8 +694.5 Main Entrance Guest Entrance Garbage Room Dining Room Shower Foyer Kitchen PatioFitness Studio Main Bedroom Bathroom Media Office / Library Jacuzzi Terrace Terrace Lounge / Living Room Water Closet 491.1 SQ. FT. 203 SQ. FT. 89.4 SQ. FT.231.2 SQ. FT. 444.6 SQ. FT. 347.1 SQ. FT. 296.3 SQ. FT. 399.0 SQ. FT. 509.1 SQ. FT. 768.5 SQ. FT. 205.7 SQ. FT.135.4 SQ. FT. 45.63 m2 18.86 m2 8.31 m2 21.48 m2 41.30 m2 32.25 m2 27.53 m2 37.07 m2 47.30 m2 19.11 m2 12.58 m2 60.6 SQ. FT. 5.63 m2 Dressing Powder Room Sculpture Guest Room 341.9 SQ. FT.341.9 SQ. FT. 31.77 m2 31.77 m2 Guest Room 71.39 m2 Pool Terrace Swimming Pool Pond Electricity Room 32.2 SQ. FT. 3.00 m2 248.4 SQ. FT. 23.07 m2 211.8 SQ. FT. 19.68 m2 735.4 SQ. FT. 68.32 m2 386.2 SQ. FT. 35.88 m2 Laundry Terrace Terrace Living Area Corridor West Wing Corridor Toilet 1123.8 SQ. FT. 104.41 m2 792.4 SQ. FT. 73.62 m2 421.6 SQ. FT. 39.17 m2 Terrace Guest 94.6 SQ. FT. 8.79 m2 255.6 SQ. FT. 23.74 m2 1939.0 SQ. FT. 180.14 m2 Terrace 321.7 SQ. FT. 29.89 m2 Terrace Brasero 306.0 SQ. FT. 28.43 m2 brasero brasero +683+680 +675 +6 7 4 +673+672+671+670+667+666+665+ 6 6 0 +682+676 +677 +678 +679+681+684.75 +684.75 +683.25+683.25 +681.75+680.25+708.9 +703.9+703.9 +698.9 +708.9 +706.4 +708.9 36'-5" in [11.10 m]46'-0" in [14.02 m] 40'-8" in [12.39 m]50'-4" in [15.34 m]41'-6" in [12.65 m]39'-6" in [12.04 m]56'-4" in [17.17 m]9'-0" in [2.74 m] 32'-0" in [9.75 m] 48'-0" in [14.63 m]75'-7" in [23.04 m]23'-0" in [7.01 m] 35'-0" in [10.67 m] 10'-4" in [3.15 m] '_matchprop solar panels: installed low and parallel to roof single ply roofing membrane, typ. 0 A2.3 Roof Plan 8'Plot Date: 10/9/2024 Login Name: Rs File Name: PS A2.1 Floor Plan211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 01Roof Plan 1/8" = 1'-0" +685 +698.9 +703.9 +706.4 +703.9 12'-0"13'-0"+688 +689.513'-0"14'-0"+689 +686.5 +708.9+708.9 13'-0"14'-6"15'-6"fixed sunscreen custom composite concrete block plaster roof fascia painted steel C-channel low-iron glazing painted steel C-channel travertine terrace 8'-0"23'-0"+692.5 +684 +706.4 +708.9 +698.9 +694 +708.9 13'-0"14'-6"12'-0"9'-0"+685 plaster roof fascia painted steel C-channel low-iron glazing painted steel C-channel travertine terrace 0 A3.1 Exterior Elevations 8'Plot Date: 10/9/2024 Login Name: Rs File Name: PS A3.1 Exterior Elevations211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain 02West Elevation 1/8" = 1'-0" 01East Elevation 1/8" = 1'-0" ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 +691 +68913'-6"+692.5 12'-6"14'-6"+708.9 +703.9 +706.4 17'-10"21'-3"plaster roof fascia painted steel C-channel fixed sunscreen painted steel C-channel travertine terrace Terrace Brasero +694 +698.9 12'-0"+686.5 +688 9'-0"13'-0"+708.9 +68414'-0"13'-6"+706.4 +703.9 +68813'-0"+685 25'-7"plaster roof fascia painted steel C-channel low-iron glazing painted steel C-channel travertine terrace low-iron glass guardrail travertine terrace fixed sunscreen 0 A3.2 Exterior Elevations 8'Plot Date: 10/9/2024 Login Name: Rs File Name: PS A3.1 Exterior Elevations211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain 02South Elevation 1/8" = 1'-0" 01North Elevation 1/8" = 1'-0" ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 30'-0" max ht.natural grade 27'-1" in [8.26 m]max. heightsolar panels, installed low and parallel to roof fixed sunscreen Foyer Main Bedroom Office / Library Bikes Terrace Mechanical +708.9 +684 +706.4 14'-6"23'-0"24'-11"13'-0"+708.9 +692.5 +694.0 +692.5 12'-0"GardenDressingDressing 9'-0"Driveway natural grade 30'-0" max ht.Dining Room FoyerKitchen Main Bedroom Laundry15'-6"13'-0"+691.0 +689 +706.4 14'-6"10'-6"+703.9 +694 Patio +708.9 13'-6"Plot Date: 10/9/2024 Login Name: Rs File Name: PS A4.1 Sections211 Ridge Mountain Dr Palm Springs CA 92264 DESIGN ARCHITECT Wilmotte & Associés Architectes 68 Rue de Faubourg Saint-Antoine Paris, France 75012 +33 (0)1 53 02 22 Contact : Gustavo Boscan ARCHITECT OF RECORD KOVAC 11828 West Pico Boulevard Los Angeles CA 90064 +1 310 575 3621 Contact : Thomas Schneider Ridge Mountain 0 A4.1 Sections 8'02North-South Section 1/8" = 1'-0" 01East-West Section 1/8" = 1'-0" ISSUANCE DATE Pre-Submittal 1 Mar 2024 ARC Submittal 7 Jun 2024 ARC Submittal 12 Sep 2024 ARC Submittal 9 Oct 2024 2,8 in 20,1 inCONCRETE BLOCKS PALM SPRINGS - U.S.A RALSTON/WHYTE PRIVATE HOUSE ARCHITECTURE Color: Clear anodized aluminum Finish: matte Glazing ExtraClear glass Low-e glazing | Low iron Lowe’s snow white marble mosaic Plaster Color: white Finish: matte Fiber cement composite Color: Blanc Titane 101 Finish: matte Custom Metal Column Color: titanium Finish: satin MATERIAL BOARD WINDOW / FRAMEGLAZING POOL / JACUZZI ROOF/WALL SLAB-EDGE COLUMN PALM SPRINGS - U.S.A RALSTON/WHYTE PRIVATE HOUSE Travertine Color: grey FLOORING / TERRACE Custom Concrete Block with Metal Joint Color: white Finish: matte CLAUSTRA +685+685+685+691+694+692.5+688+691+688+688+685+694+692.5+688+688+686.5+686.5+689.5+685+686.5+689.5+692.5+687.5+691.5+693.0+694.0+696.0+700.0+698.0+692.5+694+685+688+688AC-2663662661660659658658657657656656655655654654653653652652651651650650649649648648647647646646645644643642SCAR AREAREVISED HEREONBC-2 CC-2D C-2E C-2 FC-2GC-21C-2 2C-23C-2TWO WORKING DAYS BEFORE YOU DIGUnderground Service AlertAPPROVEDDATEREVISIONNO.LOCATIONBENCHMARKELEV.PREPARED UNDER THE DIRECT SUPERVISION OF:DESIGN BY:DRAWN BY:REVIEWED BY:CITYCHECKDATERIGHT-OF-WAYTRAFFICENG'GFIELDENG'G::::::INITIALDATE::::::APPROVED BY:JOEL MONTALVODATER.C.E. NO.CITY OF PALM SPRINGS, CALIFORNIAFILE NO.DWG. NO.OF X SHTS.SHEETDATECADD FILE NAMER.C.E. NO.REVIEWED BY:211 RIDGE MOUNTAIN DR.FLCBFLJOHN M. BRUDIN41836CPS 35-10532.95862624Labib Funk & AssociatesFrank LaRocca, P.E.319 Main StreetEl Segundo, CA 90245T: 213/ 239 9700 F: 213/ 239 96998111PRECISE GRADING PLAN TWO WORKING DAYS BEFORE YOU DIGUnderground Service AlertAPPROVEDDATEREVISIONNO.LOCATIONBENCHMARKELEV.PREPARED UNDER THE DIRECT SUPERVISION OF:DESIGN BY:DRAWN BY:REVIEWED BY:CITYCHECKDATERIGHT-OF-WAYTRAFFICENG'GFIELDENG'G::::::INITIALDATE::::::APPROVED BY:JOEL MONTALVODATER.C.E. NO.CITY OF PALM SPRINGS, CALIFORNIAFILE NO.DWG. NO.OF X SHTS.SHEETDATECADD FILE NAMER.C.E. NO.REVIEWED BY:211 RIDGE MOUNTAIN DR.FLCBFLJOHN M. BRUDIN41836CPS 35-10532.95862624Labib Funk & AssociatesFrank LaRocca, P.E.319 Main StreetEl Segundo, CA 90245T: 213/ 239 9700 F: 213/ 239 96998112GRADING SECTIONS