HomeMy WebLinkAboutesgil 2018-1661 Check 29320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576 DATE:07/13/18 APPLICANT JURIS. JURISDICTION:Palm Springs PLAN CHECK #.:2018-1661 SET:II PROJECT ADDRESS:979 San Lorenzo PROJECT NAME:Luxury Investments SFR The plans transmitted herewith have been corrected wh ere necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Donovan Dodd EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted:Donovan Dodd Telephone #: (760)610-9620 Date contacted:(by:) Email: donovan@controlledconstructioninc.com Mail Telephone Fax In Person REMARKS: By:Javier Snider (DA)Enclosures: EsGil 07/05/18 Palm Springs 2018-1661 07/13/18 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not n ecessarily be in sequence.The notes in bold font are current. PLANS 1.Please make all corrections and submit THREE new complete sets of prints,to the Palm Springs building department . Please note: Before correcting the plans, you should wait until you’ve received comments from other city departments (Fire, Planning, etc.). 2.Prior to resubmittal please contact and coordinate with the city. The current permit is for a remodel and addition. The permit should include legalization of unpermitted constructio n. Please do not resubmit any plans until this issue has been addressed and documentation can be provided for verification. After this process has taken place please review plans and make the necessary adjustments to coordinate intent. 3.The next set of plans shall include sheets with existing conditions as they are currently. These sheets shall not have any proposed work, or structures or items that are not in place. They shall show foundation, walls with type, roofing, and any structural, electrical, mech anical, plumbing pertinent to this project (as is). Dimensions and design features shall also be provided.NOTE: Additional corrections may result. FIRE PROTECTION 5.An automatic residential fire sprinkler system shall be installed in one-and two-family dwellings (not required for additions if the existing dwelling doesn’t already have a sprinkler system). Please clearly note this on the plans. Section R313.2.Palm springs does not allow deferred elements. 6.In dwelling units within which fuel-burning appliances are installed (and in dwelling units having attached garages), show the locations of permanently wired carbon monoxide alarms with battery backup, per Section R315:Change CO2 to CO and please change sheet E -3 to E-1 ROOFS/DECKS/BALCONIES 7.Specify on the plans the following information for the roof materials, per Section R106.1.1:Please address all a.Manufacturer’s name and product name/number. b.ICC approval number, or equal. 9.Roof plan shows hips and ridges, but the framing plan shows flat roof joists. Please detail how slope and ridges will be accomplished. Palm Springs 2018-1661 07/13/18 FOUNDATION REQUIREMENTS 12.Please review foundation and framing plan. There are several shearwalls shown on both that do not have footings as required.Section R403.Please check again. STRUCTURAL 15.Specify nail size and spacing for the floor and roof diaphragms on the plans. Table R602.3(1). Specify plywood and/or particle board thickness, grade and panel span rating. Table R503.2.1(1) MECHANICAL 19.Specify on the plans the following information for the fireplace(s):Please provide specific model to be used as not all are allowed. a.Manufacturer’s name/model number and ICC approval number, or equal. ELECTRICAL 20.Please check the outlet distances in the bedroom s. No point on the floor should be 6’ from an outlet. MISCELLANEOUS 33.Please be advised that due to the disparity between the scope of work and the plans additional corrections may be found to apply after revision. 34.To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. 35.Have changes been made to the plans not resulting from this correction list? Please indicate: Yes No  36.The jurisdiction has contracted with EsGil,located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560 -1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Javier Snider (DA)at EsGil. Thank you.