2019-2230 - Job Card
• 0 Fire Department 300 North El Cielo Road Palm Springs, CA 92262 www.palmspringsca.gov JOB CARD Project address: 979 E San Lorenzo Rd Permit #: 2019-2230 Inspection hours 8AM - 5PM Monday - Thursday Fire Dept Inspection request line (760) 323-8186 Fire Plans Examiner (760) 323-8184 NFPA 13D Fire Sprinklers (Single -Family detached) Plan ReviewOnly INSPECTIONS Thrust Block Hydro :?4o iNSP CTIONS CALLED Flush PFRM11 EXVIRED --- Pre-Wire F11,F, CLOSED CITY OF PALM SPRINGS TRANSMITTAL FORM Date: 6/13/19 To: edith@desert-fire.com Subject: SFD — Fire Sprinklers 13D Address: 979 E. San Lorenzo Permit #: 2019-2230 Plan Checker: Stephen Otero, Fire Plans Examiner II Stephen.otero(cDpalmspringsca.gov / 760-323-8184 Status: Plans were received for the following type of project: _X_ Plan is approved Plan is approved with conditions Plan is approved with redlines Plan requires corrections, see attached list Other: X_ Fire Sprinklers Fixed Fire Protection System Fire Alarm System Underground Fire Service Architectural Other: City of Palm Springs -"Fire Prevention Aau 4+. City Hall Office: 3200 E. Tahquitz Canyon Way Palm Springs, CA 92262 Phone: (760) 323-8186 FIRE PERMIT APPLICATION ❑✓ New ❑ Revision # FD Permit # Building Permit# Assessor Parcel#(APN): Project Name: SAN LORENZO RESIDENCE Address: 979 E. SAN LORENZO ❑As-builts Submit 3 complete sets Minimum size of plans 18"X 24" Minimum scale'/4"= 1" Maximum size of plans 40" X 36" Please complete all sections. Const. Type: RESIDENTIAL Occupancy Classification: RESIDENTIAL City & Zip: PALM SPRINGS 92262 Square Feet: "`\. a`` a, .,a.: -.'. 9 � b ,J x : •- ! 'E,4°£4£.l�A ��JJ JlYf '�"a!! <�� !Jr!»hJ �. ,,�\��,"ji Company Name: DESERT FIRE EXTINGUISHER CO., INC Applicant Name: MARK TRELAK Address:558 E. INDUSTRIAL PLACE Phone:7603220995 city/ zip: PALM SPRINGS 92262 Email: EDITH@DESERT-FIRE.COM Company Name: Contact Name: Address: Phone: City/ Zip: Plan Review Type (Check appropriate items) Email: ❑Commercial ✓ Residential ❑Other Construction:❑Water/Access❑Exit Analysis Sprinkler: ❑NFPA 13 ❑ NFPA 13R ❑✓ NFPA 13D Fire Alarm: ❑Fire Alarm ❑Monitoring Mech. Systems: Hood/Duct Alt. Systems: FM200❑Wet Chem.❑Dry Chem. ❑Foam❑CO2❑Halon Other: Form I —Revised 2/28/2019 Visit us at www.palmsprinasco.gov i Q?ALM S� City of Palm Springs 3200 Eagt Tahquitz Canyon Way Palm Springs, CA 92262 Phone: Bldg: 760-323-8242 Eng: 760-323-8253 Fax: See Below ACCOUNT: Desert Fire Extinguisher Co P.O. Box 1607 Palm Springs CA 92263 Phone: 760 322 0995 Oid ' Receipt Summary Page 1 of ,1 DATE 6/11/2019 PERMIT NUMBER 1 2019-2230 979 E San Lorenzo Rd LOT 9 BLK H MB 022/069 TAHQUITZ RIVER ESTATE Palm Springs, CA 92264 Date Reference Number Invoice Number FeeCat Description Status 6/11/2019 2019-2230 19-2619 001-34210 Fire Plan Review Paid Amount (-) 170.00 Date InvoiceNum Status Payment Amount 6/11/2019 6/11/2019 19-2619 19-2619 Original Due Paid Check409 170.00 () 170.00 Total Paid 170.00 Building Fax #: 760-322-8342 Engineering Fax #: 760-322-8325 .n r� _ _ _ Fire Protection by Computer Design DESERT FIRE EXTINGUISHER CO.,I Job Name SAN LORENZO RESIDENCE Building RESIDENTIAL Location LIVING ROOM System 1 Contract 01019 Data File SANLORENZO RESIDENCE.(palm springs).WXF DESERT FIRE EXTINGUISHER CO.,I Page 1 SAN LORENZO RESIDENCE Date 6/10/19 HYDRAULIC DESIGN INFORMATION SHEET Name - SAN LORENZO RESIDENCE Location - LIVING ROOM Date - 6/10/19 Building - RESIDENTIAL System No. - 1 Contractor - DESERT FIRE EXTINGUISER Contract No. - 01019 Calculated By - ANGI VILLAMENA Drawing No. - 1 Construction: (X) Combustible ( ) Non -Combustible Ceiling Height 10'-0 OCCUPANCY - 13D RESIDENTIAL S Type of Calculation: (X)NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )l (X)2 ( )4 ( ) S ( ) Other T ( )Specific Ruling Made by Date E - M Listed Flow at Start Point - 13.4 Gpm System Type Listed Pres. at Start Point - 7.5 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16-0 x 16-0 ( ) Deluge ( ) PreAction E Domestic Flow Added - 5 Gpm Sprinkler or Nozzle S Additional Flow Added - 0 Gpm Make TYCO Model FR-11 I Elevation at Highest Outlet - 0 Feet Size 7/16 K-Factor 4.9 G Note: Temperature Rating 155 DEG.F N Calculation Gpm Required 32.037 Psi Required 44.748 At Test Summary C-Factor Used: Overhead 150 Underground 150 W A T E R S P P L Y Water Flow Test: Pump Data: Tank or Reservoir: Date of Test - Rated Cap. Cap. Time of Test - @ Psi Elev. Static (Psi) - 120 Elev. Residual (Psi) - 20 Other Well Flow (Gpm) - 1000 Proof Flow Gpm Elevation - Location: 979 E. SAN LORENZO Source of Information: PALM SPRINGS FIRE DEPT o..,.,.. a„ u„,lnr Rniit= I I I Winrihnm N.H. USA 03087 AI O N t�D N N a. o O U W w =U z � C� 0 Uz cn X cc >' w O QLIJ T-Z i. cc IO 0 Ca rl�OC) r,m MOB O� �cq mC,)� (li ?i cn ^ E O 2 p N CLLCL Cin C O E E co E 2) tdNCU(Da)co > N N0 row W (D Cn CD U) �rNN OM (SS cbO=bCn E N n • CD �a.LL 7 (n V) cn ., m a) �U)rrXr m RSTNN 2�,000 CU N V O O O O O O O O Ln O r O< OZ LL O O L O O d' 0 0 M 0 N U 0 0 c� r t0f7 CO cmOr O O O O O O Oi O O O T T T T r T a) CO � co � �1 M N T a. = w U w D m w d 0 cc � ƒq E g // � xƒ L D kW tm CR LL \k _Q 2 $000 & ]coo Q moon R %000$2 v000gm �000%m �ocog8 c0000a» It n00c-F�(D CkjF- Ln_Lf) U') mr- n-o« _ r-cr %U e Sd M / 2U) kCD ƒ moo mmff= § W (1) m cnS%32Q <000« a.»>aiL LLELCL(LLLU- z000zz w}0CCne iE � § kU) o k $ G2 Oc k /0 0 @e @ a555 c))22=c EI>27 k�/tk �2 3£o NCO 0mm��� § � 2 2 7 LL 0 .2cZ E2:3 12 k »t��kU ///\3 =(D bum k; = E § %a/�/ $/J�\t Lm E a) �. � \ /-\ 2e c2e C k kk m2 $&/kk� \ §� k k k & 0-0 _a)_�- =�0co \£�@»« ooczco= i§�E< \ o c2o=�Q @o§=&o >o3kƒ §\mEgQ 2=-==� Zw200a Pressure / Flaw Summary - STANDARD DESERT FIRE EXTINGUISHER CO.J Page 4 Date 6/10/19 SAN LORENZO RESIDENCE Node Elevation K-Fact Pt Pn Flow Density Area Press Reg. No. Actual Actual _ _ _____ 1 10.0 4.9 7.5 na 13.42 0.05 13 7.5 2 10.0 4.9 7.72 na 13.62 0.05 13 7.5 3 11.0 7.26 na 4 11.0 7.56 na 5 11.0 8.06 na 6 11.0 10.67 na 7 13.0 18.69 na 8 13.0 21.6 na TR 13.0 23.53 na BR 2.0 31.45 na 5.0 X 2.0 34.09 na EL 0.0 35.49 na WM 0.0 37.87 na CM 0.0 44.75 na The maximum velocity is 13.22 and it occurs in the pipe between nodes WM and CM 0-+n 111 Winriham N-H_ 11SA 03087 Final Calculations - Hazen -Williams Page 5 DESERT FIRE EXTINGUISHER CO -,I Date 6/10/19 SAN LORENZO RESIDENCE Hyd. Qa Dia. RC" Fitting Pipe Ftng's Pt Pt Pe Pv ******* Notes ****** Ref. Point Qt Pf/Ft or Eqv. Ln. Total Pf Pn 13.42 1.101 O 5.0 1.000 7.500 K Factor = 4.90 1 to 150.0 0.0 5.000 6.000 -0.433 0.195 Vel = 4.52 3 13.42 0.0325 0.0 0.0 7.262 K Factor = 4.98 _ _ 13.42 N 7.0 1.000 7.723 K Factor = 4.90 2 to 13.62 1.101 150.0 0.0 7.000 -0.433 Vel = 4.59 4 13.62 0.0335 0.0 - 8.000 0.268 _ 0.0 7.558 K Factor_= 4.95 - 13.62 3 13.42 1.101 N 7.0 12.500 7.262 to 150.0 0 5.0 0.0 12.000 24.500 0•0 0.797 Vel = 4.52 5 13.42 0.0325 0.0 8.059 K Factor = 4.73 13.42 _ 4 _ 13.62 1.101 N 7.0 3.000 7.558 to 150.0 0 5.0 0.0 12.000 15.000 0.0 0.501 Vel = 4.59 5 13.62 0.0334 5 _ 13.42 1.101 R 1.0 14.000 8.059 to 150.0 N 7.0 0.0 8.000 22.000 0•0 2.614 Vel = 9.11 _ 6 27.04 0.1188 6 0.0 1.101 811 8.0 54.750 10.673 to 150.0 0 5.0 20.000 -0.866 8.884 Vel = 9.11 7 27.04 0.1188 N 7.0 74.750 7 0.0 1.101 R 1.0 18.500 18.691 to 150.0 0 5.0 0.0 6.000 24.500 0.0 2.911 Vel = 9.11 8 27.04 0.1188 a 0.0 1.101 N 7.0 9.250 21.602 to 150.0 0.0 0.0 7.000 16.250 0.0 1.932 Vel = 9.11 TR 27.04 0.1189 TR 0.0 1.101 S 9.563 10.000 23.534 to 150.0 N 7.0 0.0 16.562 26.562 4.764 3.156 Vel = 9.11 - BR 27.04 0.1188 E 2.7 2.000 31.454 = Qa S BR to 5.00 1.025 150.0 T 6.75 9.450 0.0 Vel = 12.46 X 32.04 0.2305 0.0 11.450 2.639 _ -X 0.0 1.265 E 2.967 3.500 34.093 to 150.0 0.0 2.967 6.467 0.866 0.535 Vel = 8.18 EL 32.04 0.0827 0.0 - EL 0.0 1.394 2N 16.0 30.000 35.494 to 150.0 0.0 0.0 16.000 46.000 0.0 2.372 Vel = 6.74 W M 32.04 0.0516 W M 0.0 0.995 T 5.841 20.000 37.866 to 150.0 0.0 0.0 5.841 25.841 0•0 6.882 Vel = 13.22 CM 32.04 0.2663 - 0.0 44.748 K Factor = 4.79 32.04 - Dn It- 1 11 W inrihnm N.H. USA 03087 PALM SPRINGS FIRE DEPT 1 Hydrant Flow Test By Hydrant Hydrant Number = 11117 979 SAN LpRExzo RD 117 Pitot 2 GPM 20 PSI 10 PSI 0 PSI Static Residual Pitot 0 0 0 Date p 0.00 0.00 0 11/28/2018 110 _ _ 10372 Ferguson, Rande - - -0 __-__---o----- --__ - 0 0 -- - - - - 0.00 0.00 05/21/2019 ___ 16173 Otero,Stephen ------- --- Min: ____.,____-__---- O ""____0 0 Subtotal Flow Tests: Max: 0 0 0 0 Avg: Total Flow Tests: 2 Page 1 1 08:53 9) 05/21/2019 * Scheduled Flow Test tqca Worldwide www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate. Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are dec- orative, fusible solder sprinklers, avail- able in both ordinary 160°F (71°C) and 212-F (100°C) temperature rated con- figurations. They are designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Con- cealed Pendent Sprinklers provides 1/2 in. (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprin- kler drops. The Series LFII Residential Concealed Pendent Sprinklers are intended for use in the following scenarios: • Wet and dry pipe residential sprin- kler systems for one and two fam- ily dwellings and mobile homes per NFPAI3D • Wet and dry pipe residential sprin- kler systems for residential occupan- cies up to and including four stories in height per NFPA 13R IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. • Wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Concealed Pendent Sprinklers have been designed with heat sensitivity and water distri- bution characteristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into the plaster board, ceiling tiles, and so on, by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly is installed. Dry Pipe System Application The 160°F (71°C) temperature rated Series LFII Residential Concealed Pendent Sprinklers offer a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non -water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13, 13D, or 13R. The Series LFII Residential Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the NATIONAL FiRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 Paqe 1 of 6 DECEMBER 2018 TFP442 TFP442 Page 2 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to all requirements of NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are Listed only when installed with LFII Con- cealed Cover Plates having factory -applied finishes. Sprinklers and Cover Plates are separately ordered. Refer to the Ordering Procedure section for more information. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi" (70,6 LPM/bar") Temperature Rating Ordinary 160°F (71°C) Sprinkler/ 1390F (59°C) Cover Plate NOTE: Maximum Ambient Ceiling Temperature for the ordinary temperature configuration is 100°F (38°C) Intermediate" 212°F (100°C) Sprinkler/ 165°F (74°C) Cover Plate `For wet pipe systems only NOTE: Maximum Ambient Ceiling Temperature for the intermediate temperature configuration is 150°F (65°C) Vertical Adjustment 1/2 in. (12,7 mm) Finishes Refer to Ordering Procedure section Physical Characteristics Body..............................Brass Cap..............................Bronze Saddle ........................ ....Brass Sealing Assembly.. Beryllium Nickel w/TEFLON Soldered Link Halves ................ Nickel Lever.............................Bronze Compression Screw..................Brass Deflector .................. Copper or Brass Guide Pin Housing ..................Bronze Guide Pins ......... Stainless Steel or Bronze Support Cup ....................... Steel Cover Plate .................Copper/Brass"' Retainer ......................... Copper Cover Plate Ejection Spring .... Stainless Steel " Brass Cover Plate is offered for Intermediate Tem- perature 165°F (74-C) only. Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link -halves separate BODY SEALING (1/2,. NPT) ASSEMBLY CAP j SPRINKLER WRENCHING AREA SADDLE SUPPORT COMPRESSION CUP WITH I SCREW ROLLFORMED IN THREADS �— LEVER GUIDE I PIN SOLDER LINK I I ELEMENT I I I I GUIDE PIN I I l HOUSING I I DEFLECTOR _�_---_�-mac-- (OPERATED DEFLECTOR - --- POSITION) SPRINKLER ASSEMBLY THREAD INTO I j RETAINER SUPPORT WITH THREAD CUP UNTIL DIMPLES MOUNTING SURFACE IS o 0 FLUSH WITH EJECTION CEILING SPRING SOLDER COVER PLATE COVER TAB ASSEMBLY PLATE FIGURE i RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL and C-UL Listing, the 160°F (71°C) and 212°F (100°C) LFII Residential Concealed Pendent Sprin- klers may be utilized in wet pipe systems. Only the 160°F (71°C) LFII Res- idential Concealed Pendent Sprinklers may be utilized in dry pipe systems, per the UL and C-UL Listing. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, beamed, or sloped in accordance with NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. TFP442 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2,3 Maximum Coverage Maximum Spacing Temp. Rating 160°F (71°C), 212°F (100°C) Installation Minimum Spacing Area' ft Deflector to ft x ft x m) (m) Flow Pressure Ceiling Type (m) (m GPM psi (LPM) (bar) 12 x 12 (3,7 x 3,7) 12 (3,7) 13 (4912) 7.0 (0148) Smooth Ceilings 14 x 14 14 13 7.0 7/8 to 1-1/8 in. (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed 16 x 16 16 13 70 Ceilings per NFPA 13D or Concealed 8 (2,4) (4,9 x 4,9) (4,9) (49,2) (0,48) 13R, or 13. Installed in 18 x 18 5,5) 18 (5,5) 17 (64,3) 12.0 (0,83) beam 7/8 to 1-1/8 in. (5,5 x below bottom 20 16.7 of beam (6,11 x 6,1) {601) (75,7) (1,15) Notes: 1. For coverage area dimensions less than or between those indicated use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 GPM/ft' over the design area or the flow In accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4 K-FACTOR AND AT 3 PLATE LOIC DES GN CRITER ANCEALED T SPRINKLER (TY3596) NFPA DRY PIPE SYSTEM Minimum Flow and Residual Pressure',3 Maximum Maximum Ordinary Temp. Rating Minimum Coverage Area' Spacing ft 160°F (71°C) Deflector to Installation Spacing ft x ft (m) Flow Pressure Ceiling Type ft (m) (m x m) GPM psi (LPM) (bar) 12 x 12 (3,7 x 3,7) 12 (3,7) 13 (49,2) 7.0 (0,48) Smooth Ceilings 14 x 14 14 14 8.2 7/8 to 1-1/8 in. (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed 16 x 16 16 15 9.4 Ceilings per NFPA 13D or Concealed 8 (2,4) (4,9 x 4,9) (4,9) (56,8) 0,65 ( ) 13R, or 13. Installed in 18 x 18 5,5) 18 (5,5) 18 (68,1) 13.5 (0,93) beam 7/8 to 1-1/8 in. (5,5 x below bottom 21 (79,5) 18.4 (1,27) of beam (6,11 x 6,1) (6,01) Notes: 1. For coverage area dimensions less than or between those indicated, use the minimum requir ow area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated us- ing the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications, the greater of 0.1 GPM/ft2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFI1 3D,I D3R, AND 13 K-FACT LC DESPLA CRITERIA PENDENT (TY3596) TFP442 Page 4 of 6 SPRINKLER- 2-1/2" DIA. SUPPORT CUP (63,5 mm) 1/2" (12,7 mm) FACE OF ASSEMBLY 1/2„ � THREADED SPRINKLER NPT ADJUSTMENT FITTING OPERATED SPRINKLER COVER 1-7/8"t1 /4" PLATE (47,6 mm RETAINER 1/8" GAP t6,4 mm) i I (3,2 mm) � 1 J` 5/8" (15,9 mm) COVER- SPRINKLER- ( MOUNTING \ 1-1/8" (28,6 mm) RETAINER SUPPORT CUP 3/16" J SURFACE ASSEMBLY ASSEMBLY (4,8 mm) f DISPOSABLE DEFLECTOR IN 3-3/16" DIA. OPERATED POSITION (81,0 mm) TIP PROTECTIVE CAP FIGURE 2 RAPID RESPONSE DIMENSIONS, I PROTECTIVE DENTIAL NCAP, AND ACTIVATED DEFLECTOR CEALED PENDENT SPRINKLER 3596) The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: • The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover- age area • A minimum discharge of 0.1 GPM/ft2 over the design area comprised of the four most hydrauli- cally demanding sprinklers for actual coverage areas protected by the four sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operat- ing sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 ft for a 12 ft x 12 ft coverage area, or 20 feet for a 20 ft x 20 ft coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only. Therefore, do not apply pres- sure to the fusible Link Assembly. A 1/2 in. NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate Assembly by under -or over - tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. WRENCH RECESS t I PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 18 SPRINKLER WRENCH Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 3, install and tighten the Sprinkler/ Support Cup Assembly into the fitting. The W Type 16 Wrench will accept a 1/2 in. ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been com- pleted with the 2-1/2 in. (63 mm) diam- eter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to push on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 in. (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper oper- ation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non -factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 5 of 6 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Res- idential Concealed Pendent Sprinkler, P/N (specify): 160T(71°C) ...................51-112-1-160 212'F(100'C).................. 51-112-1-212 Note: Sprinkler and Cover Plates are separately sold. See below for Cover Plate ordering information. Cover Plate Assemblies Specify: LFII Concealed Sprinkler Cover Plate Assembly, temperature rating (specify), (specify) finish, P/N (specify): 139F(59C) Ivory (RAL1015) ...... ......... 56-204-0-135 Bright Chrome ................ 56-204-1-135 Beige (RAL1001) ..............56-204-2-135 Pure White (RAL9010)" .........56-204-3-135 Signal White (RAL9003)" .......56-204-4-135 Grey White (RAL9002).......... 56-204-5-135 Brown(RAL8028)..............56-204-6-135 Black (RAL9005) .............. 56-204-7-135 Brushed Brass ................56-204-8-135 Brushed Chrome ..............56-204-9-135 Custom Paint ............... ..56-204-X-135 165F (74C) Ivory (RAL1015) ...............56-204-0-165 Bright Chrome ................ 56-204-1 165 Beige (RAL1001) ..............56-204-2-165 Pure White (RAL9010)` .........56-204-3-165 Signal White (RAL9003) ......... 56-204-4-165 Grey White (RAL9002)......... .56-204-5-165 Brown (RALB028)...... I ....... 56-204-6-165 Black (RAL9005) .............. 56-204-7-165 Brushed Brass ................56-204-8-165 Brushed Chrome ............ ..56-204-9-165 Custom Paint ........ ......... 56-204-X-165 `Eastern Hemisphere sales only "Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Johnson Controls Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W Type 18 Sprinkler Wrench, P/N 56-000-1-265 TFP442 Page 6 of 6 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 02019 Johnson Controls. All rlOhts reserved. AN apeeiflcedona and other lnformWon shown wMetnt des ofdo anent revielon date and are sublocttochana. Mhout notice. Johnson r�.a�..1. Fire' Prd?te ction Products Series TY-FRB -- Upright, Pendent, Quick Response, General Description The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in this data sheet are quick response, standard coverage, deco- rative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a • A two-piece Style 20 (1/2 inch NPT) or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion -resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained IMPORTANT Always refer to Technical Data Sheet TFP700 for the `INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide www.tyco-fire.com Contacts 2.8, 4.2, 5.6, and 8.0 K-Factor and Recessed Pendent Sprinklers Standard Coverage when exposed to corrosive atmo- spheres. Although corrosion -resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level of the Series TY-FRB Pendent Sprinklers is detailed in Technical Data Sheet TFP356, and Sprinkler Guards are detailed in Tech- nical Data Sheet TFP780. The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY1131 - Upright 2.8K, 1/2" NPT TY1231 - Pendent 2.8K, 1/2" NPT TY2131 - Upright 4.2K, 1/2- NPT TY2231 - Pendent 4.2K, 1/2" NPT TY3131 - Upright 5.6K, 1/2-NPT TY3231 - Pendent 5.6K, 1/2" NPT TY4131 - Upright 8.OK, 3/4" NPT TY4231 - Pendent 8.OK, 3/4- NPT TY4831 - Upright 8.OK, 1/2- NPT TY4931 - Pendent 8.OK, 1/2- NPT Paae 1 of 10 NOVEMBER 2015 TFP171 TFP171 Page 2 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 7/16" (11,1 r NOMINAL 2-1/4" MAKE -IN (57,2 mm) 2-3/16" (55,6 mm) i 1-9/16" (39,7 mm) 1 1/2" NPT** I WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 - Compression Assembly Screw 4 - Bulb 6 - Deflector* 7 - Bushing I _ 2-7/8" (73,0 mm) DIA. _- RECESSED PENDENT CROSS SECTION FIGURE i QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. 7/16" (11,1 mm) NOMINAL MAKE -IN 2-3/16" (55,6 mm) i �1 1/2" NPT** WRENCH FLATS UPRIGHT PENDENT ESCUTCHEON PLATE SEATING SURFACE I — I 2-3/16" (55,6 mm) 1-112" (38,1 mm) 0 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector STYLE 10 or 20 1---- 2-7/8" (73,0 mm) DIA. — =) RECESSED ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector. special request. PLATE SEATING SURFACE 1/2" NPT** I WRENCH FLATS UPRIGHT PENDENT STYLE 10 or 20 RECESSED ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* �--- 2-7/8" (73,0 mm) DIA. — RECESSED PENDENT f�{ CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT TFP171 Page 3 of 10 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2" (12,7 mm) — NOMINAL 2-5/16" MAKE -IN / (58,7 mm) 2-1/4" I I 1-9/16" (57,2 mm) (3g,7 mm) 3/4" NPT** ( WRENCH STYLE 30 or 40 ESSED REC UPRIGHT FLATS PENDENT ESCUTCHEON �-. — 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT 7/16" (11,1 mm) NOMINAL Ll � MAKE -IN 2-3/16" (55,6 mm) 1/2" NPT ** WRENCH UPRIGHT FLATSPENDENT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6- Deflector Assembly i 3 4 - Bulb 2-1/4" (57,2 mm) 2 14 * Temperature rating is 1-9/16" 4 indicated on Deflector. (39,7 mm) ii� 5 ** Pipe thread connections - per ISO 7-1 can be m 6 * provided on special request. CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 6 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 7 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP1T1 Page 4 of 10 Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved Refer to Table A and B for complete approval information including corrosion - resistant status. Maximum Working Pressure Refer to Table C. Discharge Coefficient K=2.8 gpm/psi/" (40,3 Ipm/bars) K=4.2 gpm/psi3" (60,5 Ipm/bar'h) K=5.6 gpm/psi'h (80,6 Ipm/bar1h) K=8.0 gpm/psi'h (115,2 Ipm/bars) Temperature Rating Refer to Table A and B. Finishes Sprinkler: Refer to Table D. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ...................... Brass/Copper Sealing Assembly.. Beryllium Nickel w/TEFLQN Bulb...............................Glass Compression Screw.................Bronze Deflector ................... Copper/Bronze Bushing (K=2.8) .....................Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the require- ments of FM's Loss Prevention Data Sheets). Only the Style 10, 20, 30, or 40 Recessed Escutcheon, as applica- ble, is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 2860F (141°C) tem- perature ratings. A leak -tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.- Ibs. (13,4 to 26,8 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Pendent and Upright Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe -thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 6). With ref- erence to Figures 1 through 5, apply the W-Type 6 Sprinkler Wrench to the sprinkler wrench flats. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 7). With reference to Figures 1 to 4, apply the W Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step C. After ceiling installation and finishing, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED POLYESTER*** 2.8 1/2" NPT PENDENT (TY1231) and UPRIGHT (TY1131) 135°F(57°C) Orange 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY1231)* Figure 8 135°F (57°C) Orange 1,2,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY1231)** Figure 9 135°F (57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F(57°C) Orange 1,2 155°F (68°C) Red 175°F (79°C) Yellow 200°F 93°C) ( Green 286°F (141°C) Blue RECESSED PENDENT (TY2231)* Figure 10 135°F(57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green RECESSED PENDENT (TY2231)** Figure 11 135°F(57°C) Orange 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. 'Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" N PT)1/2" Total Adjustment Recessed Escutcheon, as applicable. "'" Frame and Deflector only. N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH (See Note 8) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED POLYESTER*** LEAD COATED PENDENT (TY3231) and UPRIGHT (TY3131) 135-F(57°C) Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 5.6 1/2" NPT RECESSED PENDENT (TY3231)* Figure 12 135-F(57°C) Orange 1, 2, 4, 5 N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 2WF (141°C) Blue RECESSED PENDENT (TY3231) Figure 13 135-F(57°C) Orange 1, 2, 3, 4, 5 N/A 155°F (68°C) Red 175'F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 8.0 3/4" NPT PENDENT (TY4231) and UPRIGHT (TY4131) 135-F(57°C) Orange 1, 2, 3, 4, 5, 6, 7 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY4231)* Figure 14 135°F(57°C) Orange 1, 2, 5 N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue RECESSED PENDENT (TY4231) Figure 15 135°F (57°C) Orange 1, 2, 3, 5 N/A 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 8 0 1/2" NPT PENDENT (TY4931) and UPRIGHT (TY4831) 135-F(57°C) Orange 1, 2, 4, 5, 6 1, 2, 5 155°F (68°C) Red 175°F (79°C) Yellow 200-F (93°C) Green 286°F (141"C) I Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers, However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead -Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. Where Lead -Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion -Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. "" Frame and Deflector only. N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K FACTOR TYPE NATURAL BRASS I CHROME PLATED POLYESTER LEAD COATED PENDENT (TY1231) and 2.8 UPRIGHT (TY1131) 175 PSI (12,1 BAR) NIA 1/2" NPT RECESSED PENDENT (TY1231) PENDENT (TY2231) and 4.2 UPRIGHT (TY2131) 175 PSI (12,1 BAR) N/A 1/2" NPT RECESSED PENDENT (TY2231) PENDENT (TY3231) and UPRIGHT (TY3131) 250 PSI (17,2 BAR) 5.6 OR 175 PSI (12,1 BAR) RECESSED 1/2" NPT (SEE NOTE 1) PENDENT (TY3231) PENDENT (TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT (TY4131) 175 PSI (12,1 BAR) 3/4" NPT RECESSED N/A PENDENT (TY4231) 8.0 PENDENT (TY4931) 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 1/21' NPT UPRIGHand T (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Under- writers Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. Care and Maintenance The TYCO Series TY-FRB must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but TABLE C MAXIMUM WORKING PRESSURE have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers -before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). Initial and frequent visual inspections of random samples are recommended for corrosion -resistant sprinklers to verify the integrity of the corrosion -resistant material of construction. Thereafter, annual inspections per NFPA 25 should suffice. Inspections of corrosion -resistant sprinklers are recommended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprin- kler condition and the long-term integ- rity of the corrosion -resistant material, which can be affected by the corrosive conditions present. TFP171 Page 8 of 10 5/8±1 /4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE _ 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) _ 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING PLATE 1/8" (3,2 mm) SERIES 1-5/16" (33,3 mm) TY-FRB 13116" (20,6 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2-7/8" DIA. 5/8±1 /4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) �NG SURFACE 111 CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3141NCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT 2-7/8" DIA. 112±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) {12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) --._I MOUNTING SPRINKLER PLATE FITTING 1!8" (3,2 mm) Ti 1 MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 1" (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT 5/8±1 /4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE CLOSURE _ 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) _ 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING PLATE 1/8" (3,2 mm) SERIES 1-114" (31,8 mm) TY-FRB 3/4" (19,1 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 518±1/4" (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING SPRINKLLEER FACE PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 14 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT TFP171 Page 9 of 10 2-7/8" DIA. 1/2±1/8° (73,0 mm) 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 1 " (25,4 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 2-7/8" DIA. 1/2±1/8(73,0 mm) 1/2" (12,7 mm) " (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) ~I MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) �NG SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 15 SERIES`TY--FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX I SIN SPRINKLER FINISH 330 2.8K UPRIGHT (1/2"NPT) TY1131 331 2.8K PENDENT (1/2"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (1/2"NPT) TY2231 370 5.6K UPRIGHT (1/2"NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.OK UPRIGHT (3/4"NPT) TY4131 391 8.OK PENDENT (3/4"NPT) TY4231 360 8.OK UPRIGHT (1/2"NPT) TY4831* 361 8.OK PENDENT (1/2"NPT) TY4931* 1 NATURAL BRASS 3 PURE WHITE POLYESTER (RAL9010)1 4 SIGNAL WHITE POLYESTER (RAL9003) 5 JET BLACK POLYESTER (RAL9005)2 7 LEAD COATED 9 I CHROME PLATED TEMPERATURE RATINGS 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 1 200 1 200°F (93°C) 1 286 1 286°F (141 °C) NOTES. 1. Eastern Hemisphere sales only. 2. Available in only 2.8K, 4.2K, and 8,OK, 155°F (68°C) and 200°F (93°C); requires lead time to manufacture. TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 * Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. vic® Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Type C UL US LISTEO Size Range — 3/4" thru 2" CPVC pipe ' Material — Pre -Galvanized Steel i' c Function — Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to sup- port CPVC pipe from under a flat horizontal surface, such as a ceiling. For this type of installation, use the TOLCO® Fig. 23, Double Fastener Strap for CPVC Piping. Fig. 22, when inverted, with the hanger tab downward, can A function as a restrainer to prevent the upward movement of the sprinkler head during activation. a Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada - (cUL) to support fire sprinkler piping. May be installed in wood using ! t fasteners supplied with product, or into minimum 20 gauge steel using (1) J. 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design pro- tects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw* furnished with the product. It is recommended that rechargeable electric drills fit- ted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish — Pre -Galvanized Order By — Figure number and CPVC pipe size. Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 27/16 15/16 13/16 51/2 5/16 9 1 271/1 6 17/16 13/16 6 5/16 9 11/4 31/16 15/e 13/16 61/2 5/16 11 '1 1/2 35/16 13/4 13/16 7 5/16 12 2 33/4 21/6 13/16 8 5/16 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737,0330 Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount C °i USLISTfl, Size Range — 3/4" thru 2" CPVC pipe C Material — Pre -Galvanized Steel - Function — Intended to perform as a hanger/restrainer to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using ? I i fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features — Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two I UL Listed hex head self threading screws" furnished with the product. It B is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a ham- mer) are allowed. Damage has been known to result from installations using B' a impact type tools. No pre -drilling of a pilot hole in wood is required. Finish — Pre -Galvanized Order By — Figure number and pipe size t Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. _ Dimensions -Weights CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3,4 25h6 15/32 13/16 51/2 5/16 9 1 25/6 15/16 13/16 6 5/16 g 11/4 3 1 Y2 13/16 61/2 5/16 11 11/2 31/4 15/a 13/16 7 5/16 12 2 3t1/16 127/32 13/16 8 5/16 15 OFFICE/MANUFACTURING FACILITY 9 1375 R0APgnni MIP . em'%IA rA 01070 . ou ac, 71� "c . [nv — ,o-i noon Viking Plastics CPVC Pipe Product Specifications BlazeMaster" CPVC Pipe Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the following enhanced listings and approvals: • According to UL Listing • Can be flush at return air plenums • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) • 20' spacing on pendent in lieu of 15' • '18' spacing on sidewall in lieu of 14' • Use with combustible concealed sprinklers • UL Listed attic sprinkler head (to protect the floor below) • UL Listed attic sprinkler head with wet system piping (feed main and ridge installation) New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI -NSF Standard 14 and complies with ANSI -NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150•F (12 bar @ 65.5•C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer's DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. • Exposed sidewall sprinkler listing for exposed pipe & fittings • 24' extended coverage sidewall sprinkler, 12" drop, 155T sprinkler head • 18' extended coverage sidewall sprinkler, 12" drop, 165°F sprinkler head • 16' extended coverage sidewall sprinkler, 12" drop, 175T sprinkler head • 14' standard coverage sidewall sprinkler, 12" drop, 200T sprinkler head Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop -in ceilings • Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150•F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer's DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer's installation instructions provided with the pipe. The manufacturer's installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. Trl tStPri ahnvp all" N11KINM a Review — Do's & Don'ts Do's • Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. • Read and follow the installation instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or firestop materials are compatible with CPVC. • Keep pipe and fittings in original packaging until needed. • Cover pipe and fittings with an opaque tarp if stored outdoors. • Follow proper handling procedures. • Use tools specifically designed for use with plastic pipe and fittings. • Use the proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end with a chamfering tool. • Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Make certain no solvent cement is on sprinkler head and adapter threads. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and only at a proper pressure. • Bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. • Keep threaded rod within 1/16" of the pipe or use a surge arrestor. • Install NIBCO® BlazeMaster® CPVC Fire Sprinkler Products in wet systems only. • Use only insulation and/or glycerin and water solutions for freeze protection. • Allow for movement due to expansion and contraction. • Ensure installers have been properly trained per the NIBCO BlazeMaster® CPVC Fire Sprinkler System Installation and Design Manual and renew your training every three years at a minimum. BlazeMaster® is a registered trademark of The Lubrizol Corporation. Don'ts • Do not use edible oils as a gasket lubricant. • Do not use petroleum or solvent -based sealants, lubricants, or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not contaminate the CPVC system with cutting oils or compressor oils. • Do not mix glycerin and water solutions in contaminated containers. • Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. • Do not allow solvent cement to plug the sprinkler head orifice. • Do not connect rigid metal couplers to CPVC grooved adapters. • Do not thread or groove CPVC pipe. • Do not use solvent cement near sources of heat, open flame, or when smoking. • Do not pressure test with air. • Do not pressure test until recommended cure times are met. • Do not exceed proper pressure for testing. • Do not use ratchet cutters below 50°F. • Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. • Do not allow threaded rod to come in contact with the pipe. • Do not install NIBCO BlazeMaster• CPVC Fire Sprinkler Products in cold weather without allowing for expansion. • Do not install NIBCO BlazeMaster• CPVC Fire Sprinkler Products in dry systems. • Do not allow puddling of cement in fittings and pipe. • Do not use dull or broken cutting tool blades when cutting pipe. Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART. IN 46516-4740 • USA • PH: 1.800.234.0227 CPVC Cross Reference Sheet STANDARD FITTINGS STANDARD FITTINGS WIBCO ' ", FIG. NO. SIZE FIG. 5001-G 1-1/4" 4233-012 BD160 H 5035 2" 4220-020 80013 w 5001-G 1-1/2" 4233-015 80161 to 5035 2-1/2" 4220 025 80014 G 5001-13 2" 4233.020 80162 5035 3" 4220-030 B0008 5001-G 2-1/2" 4233-025 80163 5035-R 1"x3/4'xt"x3/4' 4220-131 80015 Q 5001-13 3" 4233-030 80164 5006 3/4" 4217-007 80050 5018 1"x3/4" 4237-131 80200 5006 1" 4217-010 60051 504a 1-114'xt" 4237-168 80202 5006 1-114" 4217-012 80052 5018 1-1/4"x3/4" 4237-167 80201 5006 1-1/2" 4217-015 30053 5018 1-1/2"xl-1/4" 4237-212 80205 5006 2' 4217-020 80054 5018 1-1/2"xl" 4237-211 80204 5006 2-1/2' 4217.025 80055 501E 1-1/2'x3/4" 4237-210 80203 H 5006 3" 4217-030 80056 y 5018 2"xl-1/2" 4237-251 80209 m 5007 3/4' 4206-007 B0025 CD z 5018 2"xl-1/4" 4237-250 80208 "u 5007 1' 4206-010 80026 Cn 5018 2'xl' 4237-249 80207 5007 1-1/4" 4206-012 80027 0o 5018 2'x3/4" 4237-248 80206 5007 1-1/2" 4206-015 B0028 5018 2-1/2'x2" 4237-292 80211 5DO7 2" 4206-020 80039 5018 2-1/2'xl-1/2' 4237-291 80213 5007 2-1/2" 4206-025 80030 5018 2-1/2'xl-1/4" 4237-290 80214 5007 3" 4206-030 80031 5018 2-1/2'xl" N/A 80215 5007-R 1"x3/4" 4206-131 80032 5018 3"x2-1/2" 4237-339 80212 5019-H 3/4" 4253-007 N/A 5010 3"x2" 4237-338 80210 5019-H 1" 4253-010 N/A 5018 3"xl-1/2' N/A N/A 5019-H 1-1/4" 4253-012 N/A 5017 3/4" 4247-007 80100 5019-H 1-1/2" 4253-015 N/A 5017 1" 4247-010 80101 5019-H 2" 4253.020 N/A 5017 1-1/4' 4247-012 80102 5019-H 2-1/2" 4253-025 N/A N a 5017 1-1/2" 4247-015 80103 y 5019 H 3" 4253 030 N/A 5017 2" 4247-020 80104 0 5051-A 3" 4254-030 N/A 5017 2.1/2" 4247-025 80105 S 5051-2-A 3" 4256-030 N/A 5017 3' 4247-030 80106 U. 5051-H 3/4' 4251-007 N/A 5001 3/4' 4229-007 80075 5051-H 1" 4251-010 N/A 5001 1' 4229-010 80076 5051-H 1-1/4" 4251.012 N/A 5001 1-1/4" 4229-012 80077 5051-H 1-1/2" 4251-015 N/A 5001 1-1/2" 4229-015 80078 5051-H 2" 4251-020 N/A 5001 2" 4229-020 80079 5051-H 2-1/2" 4251-025 N/A CM H 5001 2 1/2" 4229 025 80080 5051 H 3" N/A N/A z 5001 3" 4229-030 80081 5011 3/4" 4201-007 6000 a p 5001-R l"x3/4" 4229-131 80220 5011 1" 4201.010 8001 5001-R 1-1/4"x1" 4229-168 N/A 5011 1 1/4° 4201-012 8002 5001-R 1-1/2"x3/4" 4229-210 N/A 5011 1-1/2" 4201-015 8003 5001-R 1-1/2"xl" 4229-211 N/A w 5011 2" 4201-020 80004 5001-R 1-1/2'xl-1/4" 4229.212 . N/A Lu 5011 2-1/2" 4201-025 8005 5001-R 2"xl' 4229-249 N/A 5011 3" 4201-030 80006 5001-R 2'xl-1/2" 4229-251 N/A 5011-R 3/4'x3/4"xl' 4201-102 80132 5035 3/4" 4220-007 80009 5011-R i"xt"x3/4" 4201-131 80260 y 5035 1" 4220-010 80010 5011-R 1'x3/4"xl" 4201 126 80134 5035 1-1/4" 4220.012 80011 0 � 5035 1-1/2" 4220-015 80012 Blazemaster° FIRE SPRINKLER VKLER FITTINGS SlazeMaster° is a registered trademark of The Lubrizol Corporation. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.B00.234.0227 CPV/C Cross Reference Sheet STANDARD FITTINGS 5011-R 1"0/4'x3/4" 1, 4201-125 Hu. r1l. 80133 5011-R i-1/4'xl-1/4'xl' 4201-168 80262 5011-R 1-1/4'xl-1/4'04" 4201-167 80261 5011-R 1-1/4'xl"xl-1/4" 4201-159 80137 5011-R 1-1/4"x1"xl" 4201-158 80136 5011-R 1-1/4"xi'x3/4' 4201-157 80135 5011-R 1-1/4"xl-1/4"xl-1/2' 4201-169 80138 5011-R 1-1 /2"xl -1 /2"xl -1/4" 4201-212 80275 5011-R 1-1 /2'x 1 -1 /2"xl' 4201-211 80264 5011-R 1-1/2'xl-1/2"x3/4" 4201-210 80263 5011-R 1-1/2"xl-1/4"xi' 4201-202 80140 N 'L uj 5011-R 1-1/2'xl-1/4'x3/4" 4201-201 80140 5011-R 1-1/2°xt-1/2"x2' 4201-213 N/A 5011-R 2'x2"xi-1/2' 4201-251 80274 5011-R 2"x2Y-1/4' 4201-250 80267 5011-R 2'x2"xl' 4201-249 80266 5011-R 2'x2"x3/4' 4201-248 80265 5011-R 2-i/2'x2-1/2"x2" 4201-292 80276 5011-R 2-1/2"x2-1/2'xl-1/2" 4201-291 80273 5011-R 2-1/2"x2-1/2"xl-1/4" 4201-290 80272 5011-R 2-1/2"x2-1/2'xi" 4201-289 00271 5011-R 3"x3'x2-1/2' 4201-339 80269 5011-R 3"x3"x2' 4201-338 80268 5011-R 3"x3"x1-1/2" 4201-337 80270 5033-E 3/4" 4257-007 N/A Z 5033-E 1" 4257-010 N/A c 5033-E 1-1/4" 4257-012 N/A 5 333-E 1-1/2" 4257-015 N/A _ 5D33-E 2" 4257-020 N/A THREADED FITTINGS INIECO FIG. NO. 5003-BI SIZE 3/4' SPEARS FIG. O 4235-007 r NO. 80142 5003-Bi 1" 4235-010 80145 5003-131 1-1/4" 4235-012 80146 5003-131 1.1/2' 4235-015 80147 5003-BI 2" 4235-020 80148 5003.2-BI 3/4' 4278-007 N/A 5003-2-BI 1- 4278-010 N/A 5003-S-BI 3/4"xl/2' 4235-101 80175E or 80175W 5003-S-BI 1"xl/2' 4235-130 80176E or80175W c a 5003-S-BI 1"x3/4' 4235-131 80179 5003-2-S-BI 3/4"xl/2" 4238-101 N/A 5003-2-S-BI 1"xi/2' 4238-130 N/A 5003-S-BT 3/4"xl/2" N/A N/A BlazeMaster• is a registered trademark of The Lubrizol Corporation. THREADED FITTINGS FIG. NO. SIZE FIG.NO- r 5003-S-BT 1"xl/2" N/A N/A 5003-BI-BSP i" N/A N/A 5003-81-BSP 1-1/4" N/A N/A 5003-BI-BSP 1-1/2" N/A N/A y w 5003-BI-BSP 2" N/A N/A I.- 5004-Bi 3/4" N/A 80157 G 5004-BI 1" N/A 80158 5004-BI 1-1/4' N/A N/A 5004-13I 1-1/2' N/A N/A 5004-13I 2" N/A N/A 5018-S-181I 1"xl/2" 4238-130BR N/A f!J Cn 5035-3-S-BI-S 1'xt"xl/2"x1/2' N/A 80462 0 5035-3-S-BI-L 1'xt'xl/2"xl/2" N/A 80463 cc C. 5007-3-S-Bi 3/4"xl/2' 4207-101 80199 5007-3-S-BI 1"xt/2' 4207-130 80198 m 5007-3-S-Bi 1"x3/4" 4207-131 N/A `L 5007-3-S-BI 1-1/4"xl/2' 4207-166 N/A 5011.3-3-S-61-S 1/2"0/2'0" N/A 80460 5011-3-3-S-BI-L 1/2"xl/2'xl' N/A 80459 5012-S-13I 1" 4202-010 N/A 5012-S-BI 3/4"x3/4"xl/2" 4202-101 80250 5012-R-S-13I 1"x3/4"xl/2" 4202-124 N/A 5012-S-81 1"xl"xi/2' 4202-130 80251 ti Lu 5012-R-S-BI 1'xi/2"xl" 4203 122 N/A t•- 5012-R-S-BI 11/4"x1"x1/2" 4202-156 80256 5012-S-BI 1-1/4"xi-1/4'xl/2" 4202-166 80252 5012-R-S-BI 1-1/2"0-1/4.0/2" 4202-199 80257 5012-S-Ell 1-1/2"0-1/2"0/2" 4202-209 80254 5012-S-BI 2"x2"xl/2" 4202-247 80253 5012-R-S-BI 2'xi-1/2'xl/2' 4202-237 80258 w 450-005 1/2' 4250-005 N/A t— a Blazemaster° FIRE SPRINKLER FITTINGS NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800.234.0227 —,r—.11lhlAi nrcirr PW i11F74 7951177 • FAX: +11574.295.3455 F5II NIBC09 BlazeMaster° Warranty NIBCO INC. LIMITED WARRANTY Applicable to NIBCO INC. CPVC Fire Protection Plastic Fittings NIBCO INC. warrants each NIBCO" BlazeMaster" Fire Protection CPVC plastic Fitting to be free from defects in materials and workmanship under normal use and service for a period of ten (10) years from date of purchase. In the event any defect occurs which the owner believes is covered by this warranty, the owner should immediately contact NIBCO Technical Services, either in writing or by telephone at 1.888.446.4226 or 1.574.295.3000. The owner will be instructed to return said product, at the owners expense, to NIBCO INC., or an authorized representative for inspection. In the or valve is defective/ a event said inspection discloses to the satisfaction NIBCO INC. shall furtheC. r pay said the installing contractor the sum oftenacement shall be ($10.00) dollars mailed free of charge to the owner, and p Y to apply on the cost of installation of said replacement fitting. TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY SPECIFICALLY EXCLUDES INCIDENTAL AND CONSEQUENTIAL DAMAGES OF EVERY TYPE AND DESCRIPTIN ESULTING FROM ANY CLAIMED TORPERSONAL INJURIES AND PROPERTY DECT INAMAGES MATERIAL OR WORKMANSHIP, INCLUDING BUT NOT LMITE Some states or countries do not allow the exclusion or limitation of incidental or consequential damages so these limitations may not apply to you.Y TO THE EXTENT PERMITTED BY LAW, IMPLIED WARRANTIES OF MERCHANTABILITY AND { FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION. t z. This warranty gives you specific legal rights, and you may also have other rights which vary: from state to state and country to country. BlazeMaster, is a registered trademark of The Lubrizol Corporation. How to Order State quantity, figure number and size for each valve or fitting you wish to order. See individual catalog pages for specific or special product designations. HOW MANY TO ORDER NIBCO' valves and fittings are decimal packed for your convenience in handling, shipping and stock - keeping. Number in master carton varies with item. POLICY ON RETURNS TO FACTORY No NIBCO valves and fittings are to be returned with- out prior written agreement. Transportation must be prepaid. A 20% charge will be made to cover cost of rehandling and reinspection. TECHNICAL ASSISTANCE Engineers, contractors, wholesalers or manufacturers may obtain special or technical assistance from any factory representative of NIBCO. Write, fax or phone. NIBCO INC. World Headquarters 1516 Middlebury Street Elkhart, IN 46516-4740 USA PH: 1,574,295.3000 or 1.888.446,4226 FAX: 1.574.295.3307 or 1.888.336.4226 To the best of our knowledge, the information contained in this publication is accurate. However, NIBCO does not assume any liability whatsoever for any on or uct use be ons ati thehncsor y or completeness oafs such information. manFinatlucefeandnwhethe�ftheees 5ftabYi nfongementf orf paltents, Isdo theosoleeresponosib responsibility contemplated NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516-4740 • USA • PH: 1.800234.0227 r[ru c[avirre PH 1 RRR 446.4226 • FAX'. 1.B00.234.0557 • INTERNATIONAL OFFICE PH: +1.219.295.3221 • FAX: +1.219.295.3455